3214990 INSULATOR Caterpillar parts
307D, 308D
Rating:
Alternative (cross code) number:
CA3214990
321-4990
3214990
CA3214990
321-4990
3214990
Weight: 0.11 pounds 0 kg.
MINI HYD EXCAVATOR,
Information:
Machine ECM
The following is a list of Diagnostic Trouble Codes (DTCs) that are associated with the relays of the machine.
Table 1
Machine ECM (MID 299)
DTC Code Description System Response
781-3 Lighting Relay : Voltage Above Normal Related lighting system will be on continuously.
781-6 Lighting Relay : Current Above Normal Related lighting system will be on continuously.
2912-3 Front Wiper Speed Control Relay : Voltage Above Normal Wiper system will not function.
2912-6 Front Wiper Speed Control Relay : Current Above Normal Wiper system will not function.
3634-3 Boom Light Relay : Voltage Above Normal Related lighting system will be on continuously.
3634-6 Boom Light Relay : Current Above Normal Related lighting system will be on continuously. A relay is a component that uses a small amount of electrical current to control a large amount of electrical current. Possible causes for an FMI 3 diagnostic code are:
The signal circuit is shorted to +battery.
The relay has failed.
The ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 6 diagnostic code are:
A short to ground exists.
The relay has failed.
The ECM has failed. A failure of the ECM is unlikely.
Illustration 1 g03862144
Schematic of the relay circuits associated with the Switch Panel
The diagram above is a simplified schematic of the wiper control connections. The schematic is electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of the Electrical Schematic to view the entire circuitry of the machine.Diagnostic Trouble Code Procedure
Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. Check the wiring harness for pinch points or abrasions. Look for and repair areas that indicate wires are exposed. If a problem with a connection is found, correct the problem and verify that the diagnostic code is active before performing a troubleshooting procedure.
Identify the active FMI code associated with the components.
Determine which code is present and use the list below to determine which procedure to follow.
FMI 3 diagnostic code, proceed to Table 2.
FMI 6 diagnostic code, proceed to Table 3.
Table 2
FMI 3 Troubleshooting
Troubleshooting Test Steps Values Results
1. Check The Machine Harness For A Short
A. Turn the key start switch and disconnect switch OFF.
B. Disconnect the relay from the harness.
C. Disconnect the ECM machine harness connectors.
D. At the ECM machine harness connector, measure the resistance between the signal contact and all other contacts that are used in the ECM.
Each resistance measurement is greater than 5Ω. OK - All resistance measurements are greater than 5 Ω.
Proceed to Test Step 2.
NOT OK - One or more readings are less than 5 Ω.
Repair: A short exists between the signal contact and the circuit with the low resistance. Repair or replace the machine harness.
Note: A resistance that is greater than 5 Ω but less than 5K Ω would indicate a loose connection or a corroded connection in the circuit. A resistance
The following is a list of Diagnostic Trouble Codes (DTCs) that are associated with the relays of the machine.
Table 1
Machine ECM (MID 299)
DTC Code Description System Response
781-3 Lighting Relay : Voltage Above Normal Related lighting system will be on continuously.
781-6 Lighting Relay : Current Above Normal Related lighting system will be on continuously.
2912-3 Front Wiper Speed Control Relay : Voltage Above Normal Wiper system will not function.
2912-6 Front Wiper Speed Control Relay : Current Above Normal Wiper system will not function.
3634-3 Boom Light Relay : Voltage Above Normal Related lighting system will be on continuously.
3634-6 Boom Light Relay : Current Above Normal Related lighting system will be on continuously. A relay is a component that uses a small amount of electrical current to control a large amount of electrical current. Possible causes for an FMI 3 diagnostic code are:
The signal circuit is shorted to +battery.
The relay has failed.
The ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 6 diagnostic code are:
A short to ground exists.
The relay has failed.
The ECM has failed. A failure of the ECM is unlikely.
Illustration 1 g03862144
Schematic of the relay circuits associated with the Switch Panel
The diagram above is a simplified schematic of the wiper control connections. The schematic is electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of the Electrical Schematic to view the entire circuitry of the machine.Diagnostic Trouble Code Procedure
Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. Check the wiring harness for pinch points or abrasions. Look for and repair areas that indicate wires are exposed. If a problem with a connection is found, correct the problem and verify that the diagnostic code is active before performing a troubleshooting procedure.
Identify the active FMI code associated with the components.
Determine which code is present and use the list below to determine which procedure to follow.
FMI 3 diagnostic code, proceed to Table 2.
FMI 6 diagnostic code, proceed to Table 3.
Table 2
FMI 3 Troubleshooting
Troubleshooting Test Steps Values Results
1. Check The Machine Harness For A Short
A. Turn the key start switch and disconnect switch OFF.
B. Disconnect the relay from the harness.
C. Disconnect the ECM machine harness connectors.
D. At the ECM machine harness connector, measure the resistance between the signal contact and all other contacts that are used in the ECM.
Each resistance measurement is greater than 5Ω. OK - All resistance measurements are greater than 5 Ω.
Proceed to Test Step 2.
NOT OK - One or more readings are less than 5 Ω.
Repair: A short exists between the signal contact and the circuit with the low resistance. Repair or replace the machine harness.
Note: A resistance that is greater than 5 Ω but less than 5K Ω would indicate a loose connection or a corroded connection in the circuit. A resistance
Caterpillar parts catalog:
Parts insulator Caterpillar catalog:
3214989
INSULATOR
307D, 308D
307D, 308D
3557763
INSULATOR
305D CR
305D CR
2821655
INSULATOR
304C CR, 305.5D, 305C CR
304C CR, 305.5D, 305C CR
2821656
INSULATOR
303.5C, 303.5D, 303C CR, 304D CR
303.5C, 303.5D, 303C CR, 304D CR
3243948
INSULATOR
312C L
312C L
3054894
INSULATOR
312C L
312C L
2457872
INSULATOR
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR,...
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR,...
2457905
INSULATOR
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
2457828
INSULATOR
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
2457827
INSULATOR
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
2457826
INSULATOR
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
2457825
INSULATOR
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...