5V2972 JOINT GROUP Caterpillar parts
950B, 950B/950E
Rating:
Alternative (cross code) number:
CA5V2972
5V-2972
5V2972
CA5V2972
5V-2972
5V2972
Weight: 27 pounds 12 kg.
WHEEL LOADER,
Related part:
5V2972
UNIV JT-YM
5287169
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$195.45
17 Mar 2022
US: Florida-Parts-Z
5V2972 - Universal Joint Group fit Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Information:
Conditions Which Generate This Code:
Illustration 1 g00530281
System Schematic For Alarm Module (ALM)The alarm module (ALM) is available as an option. The alarm module may be mounted on the front panel. Also, the alarm module may be placed at a distance from the control panel as a remote annunciator. The alarm module is used in order to satisfy the requirements of the customer. The alarm module may be used in order to satisfy National Fire Protection Association (NFPA) requirements by annunciating the presence of a diagnostic code.The ALM communicates with the GSC+ by a serial data link. When the data link malfunctions, all of the indicators on the ALM, that are controlled by the data link, flash at a rate of .5 Hz.Note: The maximum number of the ALM or the Customer Interface Module (CIM) that may be connected to the serial data link is equal to three. The maximum distance between a module and the GSC+ is 305 m (1000 ft). If these specifications are not met, the ALM indicators may begin to flash. Also, the GSC+ may show a CID 0333 FMI 03. If the setup is not in compliance with the specifications, reduce the number of modules and/or shorten the distance to the modules.Note: Diagnostic codes are created when the harness connector is disconnected from the GSC+ during these troubleshooting procedures. Clear these created diagnostic codes after the particular problem is corrected and the diagnostic code is cleared. The possible cause of a CID 0333 FMI 03 diagnostic code is a short to "B+".The GSC+ treats a CID 0333 FMI 03 as an alarm fault. Clear the diagnostic code from the fault log after troubleshooting is complete.Note: If a CID 0333 FMI 03 is active on the upper display and no alarm module is installed, then check the terminal strips on the subpanel for a short. Perform the check from the signal wire to "B+". Also, check the customer connection box for a short from the alarm data signal wire to "B+".Test Step 1. CHECK IF THE DIAGNOSTIC CODE IS ACTIVE
Turn the engine control switch (ECS) to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "Alarm Codes" key.
Observe the upper display for a CID 0333 FMI 03. The diagnostic code is active if the upper display shows a CID 0333 FMI 03.
If the diagnostic code is not showing, enter the service mode and view the fault log. Check the upper display if the diagnostic code is active.Expected Result:A CID 0333 FMI 03 is active.Results:
OK - A CID 0333 FMI 03 is active. Proceed to test step 2.
NOT OK - A CID 0333 FMI 03 has not occurred. The diagnostic code is NOT active. Stop.Test Step 2. CHECK FOR SHORTED DATA LINK WIRE
Disconnect the cable on the "B-" terminal of the battery or open the optional battery disconnect switch.
Disconnect both ends of the data link wire. The following contacts are the ends of the data link wire: contact 35 of the
Illustration 1 g00530281
System Schematic For Alarm Module (ALM)The alarm module (ALM) is available as an option. The alarm module may be mounted on the front panel. Also, the alarm module may be placed at a distance from the control panel as a remote annunciator. The alarm module is used in order to satisfy the requirements of the customer. The alarm module may be used in order to satisfy National Fire Protection Association (NFPA) requirements by annunciating the presence of a diagnostic code.The ALM communicates with the GSC+ by a serial data link. When the data link malfunctions, all of the indicators on the ALM, that are controlled by the data link, flash at a rate of .5 Hz.Note: The maximum number of the ALM or the Customer Interface Module (CIM) that may be connected to the serial data link is equal to three. The maximum distance between a module and the GSC+ is 305 m (1000 ft). If these specifications are not met, the ALM indicators may begin to flash. Also, the GSC+ may show a CID 0333 FMI 03. If the setup is not in compliance with the specifications, reduce the number of modules and/or shorten the distance to the modules.Note: Diagnostic codes are created when the harness connector is disconnected from the GSC+ during these troubleshooting procedures. Clear these created diagnostic codes after the particular problem is corrected and the diagnostic code is cleared. The possible cause of a CID 0333 FMI 03 diagnostic code is a short to "B+".The GSC+ treats a CID 0333 FMI 03 as an alarm fault. Clear the diagnostic code from the fault log after troubleshooting is complete.Note: If a CID 0333 FMI 03 is active on the upper display and no alarm module is installed, then check the terminal strips on the subpanel for a short. Perform the check from the signal wire to "B+". Also, check the customer connection box for a short from the alarm data signal wire to "B+".Test Step 1. CHECK IF THE DIAGNOSTIC CODE IS ACTIVE
Turn the engine control switch (ECS) to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "Alarm Codes" key.
Observe the upper display for a CID 0333 FMI 03. The diagnostic code is active if the upper display shows a CID 0333 FMI 03.
If the diagnostic code is not showing, enter the service mode and view the fault log. Check the upper display if the diagnostic code is active.Expected Result:A CID 0333 FMI 03 is active.Results:
OK - A CID 0333 FMI 03 is active. Proceed to test step 2.
NOT OK - A CID 0333 FMI 03 has not occurred. The diagnostic code is NOT active. Stop.Test Step 2. CHECK FOR SHORTED DATA LINK WIRE
Disconnect the cable on the "B-" terminal of the battery or open the optional battery disconnect switch.
Disconnect both ends of the data link wire. The following contacts are the ends of the data link wire: contact 35 of the
Caterpillar parts catalog:
Parts joint Caterpillar catalog:
5V2978
JOINT GROUP
950B
950B
4V7084
JOINT GROUP
814B, 966D
814B, 966D
5V2978
JOINT GROUP
950B
950B
9K2815
JOINT GROUP
988B
988B
4V2959
JOINT GROUP
988B
988B
9K2814
JOINT GROUP
988B
988B
8W2893
JOINT
773B, 777B, 785, 789
773B, 777B, 785, 789
2378279
JOINT AS
AD30, R2900, R2900G, R3000H
AD30, R2900, R2900G, R3000H
1644882
JOINT
769D, 771D, 773D, 775D, 777D, 784C, 785C, 789C, 793C, 797, D350E II, D400E II
769D, 771D, 773D, 775D, 777D, 784C, 785C, 789C, 793C, 797, D350E II, D400E II
1713877
JOINT AS
D250E II, D300E II, D350E, D400E
D250E II, D300E II, D350E, D400E
1055010
JOINT
D250D, D250E, D25D, D300D, D300E, D350E, D400E, D40D
D250D, D250E, D25D, D300D, D300E, D350E, D400E, D40D
7U5633
JOINT
D250B, D250D, D250E, D250E II, D25D, D300B, D300D, D300E, D300E II, D350E, D350E II, D400E, D400E II, D40D
D250B, D250D, D250E, D250E II, D25D, D300B, D300D, D300E, D300E II, D350E, D350E II, D400E, D400E II, D40D