2645726 KIT-SEAL Caterpillar parts
583T, 587R, 587T, 621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 924G, 924H, 924HZ, 924K, 928G, 928HZ, 930K, 938K, 980H, 993K, D6K LGP, D6K2, D6K2 LGP, IT28G, PL61, PL83, PL87
Rating:
Alternative (cross code) number:
CA2645726
264-5726
2645726
CA2645726
264-5726
2645726
Weight: 0.01 pounds 0 kg.
INTEGRATED TOOLCARRIER, WHEEL TRACTOR-SCRAPER,
Compatible equipment models: 2645726:
Information:
Alarm Fault
Alarm faults indicate a condition that will not inhibit the function of the digital voltage regulator and the generator set. Alarm faults have fault codes in the 600's range. A condition such as a partial internal memory failure is an alarm fault. The generator set continues to operate at a normal level. When an alarm fault occurs, the fault code will flash on the display of the digital voltage regulator. Pressing the function key toggles the display to show the parameter for the latest fault. The user can then investigate the various parameters of the digital voltage regulator through the keypad and display. All information that is shown on the display will be flashing. Alarm faults must be reset before another alarm fault can be declared. However, a successive shutdown fault will override an alarm fault, and move the alarm fault code to the previous fault location. In order to clear an alarm fault, see System Operation, "Parameters".Resettable Shutdown Fault
Resettable shutdown faults indicate a condition where the digital voltage regulator or the generator set exhibit a degradation of power generation performance. Resettable shutdown faults have fault codes in the 700's range. Conditions such as undervoltage and overvoltage are resettable shutdown faults. The generator set continues to operate, but at a reduced level too low to sustain load (excitation voltage of 3.0 VDC or less at F1 and F2). When a resettable shutdown fault occurs, the fault code will flash on the display of the digital voltage regulator. Pressing the function key toggles the display to show ":92", the parameter for the latest faults. The user can then investigate the various parameters of the digital voltage regulator through the keypad and display. All information that is shown on the display will be flashing. In order to reset a resettable shutdown fault, activate parameter :96 or the fault reset switch. See System Operation, "Customer Options". After the fault is reset, the display will stop flashing and return to parameter :01, but parameter :92 will still contain the fault code. The digital voltage regulator will immediately begin to regulate voltage again. In order to clear the fault code, use parameter :94.Non-Resettable Shutdown Fault
Non-Resettable shutdown faults indicate a condition where the digital voltage regulator cannot be safely run. Non-resettable shutdown faults have fault codes in the 800's range. Conditions such as sensing loss and frequency loss are non-resettable shutdown faults. The generator set continues to operate, but at a reduced level too low to sustain load (excitation voltage of 3.0 VDC or less at F1 and F2). When a non-resettable shutdown fault occurs, the fault code will flash on the display of the digital voltage regulator. Pressing the function key toggles the display to show ":92", the parameter for the latest faults. The user can then investigate the various parameters of the digital voltage regulator through the keypad and display. All information that is shown on the display will be flashing. In order to reset a non-resettable shutdown fault, remove power
Alarm faults indicate a condition that will not inhibit the function of the digital voltage regulator and the generator set. Alarm faults have fault codes in the 600's range. A condition such as a partial internal memory failure is an alarm fault. The generator set continues to operate at a normal level. When an alarm fault occurs, the fault code will flash on the display of the digital voltage regulator. Pressing the function key toggles the display to show the parameter for the latest fault. The user can then investigate the various parameters of the digital voltage regulator through the keypad and display. All information that is shown on the display will be flashing. Alarm faults must be reset before another alarm fault can be declared. However, a successive shutdown fault will override an alarm fault, and move the alarm fault code to the previous fault location. In order to clear an alarm fault, see System Operation, "Parameters".Resettable Shutdown Fault
Resettable shutdown faults indicate a condition where the digital voltage regulator or the generator set exhibit a degradation of power generation performance. Resettable shutdown faults have fault codes in the 700's range. Conditions such as undervoltage and overvoltage are resettable shutdown faults. The generator set continues to operate, but at a reduced level too low to sustain load (excitation voltage of 3.0 VDC or less at F1 and F2). When a resettable shutdown fault occurs, the fault code will flash on the display of the digital voltage regulator. Pressing the function key toggles the display to show ":92", the parameter for the latest faults. The user can then investigate the various parameters of the digital voltage regulator through the keypad and display. All information that is shown on the display will be flashing. In order to reset a resettable shutdown fault, activate parameter :96 or the fault reset switch. See System Operation, "Customer Options". After the fault is reset, the display will stop flashing and return to parameter :01, but parameter :92 will still contain the fault code. The digital voltage regulator will immediately begin to regulate voltage again. In order to clear the fault code, use parameter :94.Non-Resettable Shutdown Fault
Non-Resettable shutdown faults indicate a condition where the digital voltage regulator cannot be safely run. Non-resettable shutdown faults have fault codes in the 800's range. Conditions such as sensing loss and frequency loss are non-resettable shutdown faults. The generator set continues to operate, but at a reduced level too low to sustain load (excitation voltage of 3.0 VDC or less at F1 and F2). When a non-resettable shutdown fault occurs, the fault code will flash on the display of the digital voltage regulator. Pressing the function key toggles the display to show ":92", the parameter for the latest faults. The user can then investigate the various parameters of the digital voltage regulator through the keypad and display. All information that is shown on the display will be flashing. In order to reset a non-resettable shutdown fault, remove power
Cat SIS web machinery list:
Parts kit Caterpillar catalog:
2341949
KIT-SEAL
14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M, 924G, 924GZ, 924H, 924HZ, 928H, IT28G
14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M, 924G, 924GZ, 924H, 924HZ, 928H, IT28G
2341951
KIT-SEAL
924G, 924GZ, 924H, 924HZ
924G, 924GZ, 924H, 924HZ
2341950
KIT-SEAL
924G, 924GZ, 924H, 924HZ
924G, 924GZ, 924H, 924HZ
1800040
KIT-COVER
613G, 621G, 621H, 621K, 623G, 623H, 623K, 623K LRC, 627G, 627H, 627K, 627K LRC, 631G, 637G, 657G, 69D, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789...
613G, 621G, 621H, 621K, 623G, 623H, 623K, 623K LRC, 627G, 627H, 627K, 627K LRC, 631G, 637G, 657G, 69D, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789...
2861075
KIT-SEAL
928HZ, 930G
928HZ, 930G
2603015
KIT-FASTENER
928HZ, 930G
928HZ, 930G
3199511
KIT-GAS SPRING
824H, 825H, 826H, 836H, 950 GC, 950G, 950G II, 950H, 962G, 962G II, 962H, 966G II, 966H, 972G II, 972H, 980G II, 980H, 986H, 988H, IT62H
824H, 825H, 826H, 836H, 950 GC, 950G, 950G II, 950H, 962G, 962G II, 962H, 966G II, 966H, 972G II, 972H, 980G II, 980H, 986H, 988H, IT62H
3367351
KIT-SEAL
621H, 623H, 627H
621H, 623H, 627H
2015121
KIT-SHAFT
621H, 725, 725C, 730, 730C, 735, 735B, 740, 740B, 770, 772, 773F, 775F, 777F, D250E II, D300E II, D350E II, D400E II
621H, 725, 725C, 730, 730C, 735, 735B, 740, 740B, 770, 772, 773F, 775F, 777F, D250E II, D300E II, D350E II, D400E II
2280806
KIT-SEAL
980H
980H
2281775
KIT-SEAL
980G, 980G II, 980H, 988B, 988F, 988F II
980G, 980G II, 980H, 988B, 988F, 988F II
2280808
KIT-SEAL
980G, 980G II, 980H
980G, 980G II, 980H
2006282
KIT-SEAL
120M, 12M, 140M, 14M, 160M, 16M, 24M, 583T, 587R, 587T, 725, 730, 797, 797B, 928H, 938H, 950H, 962H, 966H, 972H, 994F, CB-44B, CB-54B, D10T, D11T, IT28G, IT38H, IT62H
120M, 12M, 140M, 14M, 160M, 16M, 24M, 583T, 587R, 587T, 725, 730, 797, 797B, 928H, 938H, 950H, 962H, 966H, 972H, 994F, CB-44B, CB-54B, D10T, D11T, IT28G, IT38H, IT62H
3115970
KIT-SEAL
583T, D7E, D7E LGP, D8T, PL83
583T, D7E, D7E LGP, D8T, PL83
2100179
KIT-SEAL
322B L, 325B L, 325C FM, 325D FM, 325D FM LL, 330B L, 330C FM, 330C L, 330C MH, 330D FM, 365B, 365B II, 365B L, 583T, 587R, 587T, M325C MH, PL83, PL87
322B L, 325B L, 325C FM, 325D FM, 325D FM LL, 330B L, 330C FM, 330C L, 330C MH, 330D FM, 365B, 365B II, 365B L, 583T, 587R, 587T, M325C MH, PL83, PL87
2904559
KIT-FOAM
583T, 587R
583T, 587R
2731761
KIT-PUMP
583T, D10T, D10T2, D11R, D11T, D8T, D9T
583T, D10T, D10T2, D11R, D11T, D8T, D9T
3492653
KIT-CYLINDER HEAD
365C, 365C L, 365C L MH, 583T, 621G, 623G, 627F, 627G, 657E, 735, 740, 824H, 825H, 826H, 980H, D8T, PL83
365C, 365C L, 365C L MH, 583T, 621G, 623G, 627F, 627G, 657E, 735, 740, 824H, 825H, 826H, 980H, D8T, PL83
2395157
KIT-SEAL
583T, 587T, 725, 730, 824C, 824H, 826G, 826G II, 826H, 834G, 834H, 836G, 836H, 950 GC, 950G II, 950H, 962G II, 962H, 966H, 966M, 966M XE, 972H, 972M, 972M XE, 980G II, 980H, 980M, 982M, 986H, 988G, 98...
583T, 587T, 725, 730, 824C, 824H, 826G, 826G II, 826H, 834G, 834H, 836G, 836H, 950 GC, 950G II, 950H, 962G II, 962H, 966H, 966M, 966M XE, 972H, 972M, 972M XE, 980G II, 980H, 980M, 982M, 986H, 988G, 98...
1886298
KIT-SEAL
24M, 345B II, 583T, 587T, 740, 740B, 824C, 824G II, 824H, 826G, 826G II, 826H, 834G, 834H, 836G, 836H, 844H, 844K, 854K, 938G, 938G II, 950G, 950G II, 962G II, 966G, 966G II, 972G II, 980G, 980G II, 9...
24M, 345B II, 583T, 587T, 740, 740B, 824C, 824G II, 824H, 826G, 826G II, 826H, 834G, 834H, 836G, 836H, 844H, 844K, 854K, 938G, 938G II, 950G, 950G II, 962G II, 966G, 966G II, 972G II, 980G, 980G II, 9...
1282779
KIT-SEAL
345B II, 583T, 587T, 725, 730, 797, 797B, 824C, 824G II, 824H, 826G, 826G II, 826H, 834G, 834H, 836G, 836H, 938F, 938G, 938G II, 950G, 950G II, 962G II, 966G, 966G II, 972G II, 980G, 980G II, 980H, 98...
345B II, 583T, 587T, 725, 730, 797, 797B, 824C, 824G II, 824H, 826G, 826G II, 826H, 834G, 834H, 836G, 836H, 938F, 938G, 938G II, 950G, 950G II, 962G II, 966G, 966G II, 972G II, 980G, 980G II, 980H, 98...
1715995
KIT-BEARING
5110B, 5130, 5130B, 5230, 5230B, 583T, 587R, 587T, 793C, 844, 844K, 854G, 854K, 990, 990 II, 990K, 992G, 992K, 993K
5110B, 5130, 5130B, 5230, 5230B, 583T, 587R, 587T, 793C, 844, 844K, 854G, 854K, 990, 990 II, 990K, 992G, 992K, 993K
1958639
KIT-BEARING
320C, 320D FM, 543, 583T, 587R, 587T, 621F, 621G, 627F, 627G, HF181, HF201, HF201B, HF202, HF221, HF222, M325B, SC-57, SH-56B, SS-56
320C, 320D FM, 543, 583T, 587R, 587T, 621F, 621G, 627F, 627G, HF181, HF201, HF201B, HF202, HF221, HF222, M325B, SC-57, SH-56B, SS-56
2940910
KIT-SEAL
583T, 587R, 587T
583T, 587R, 587T