Information:
Detailed FMI Explanation
FMI 00 "Data Valid But Above Normal Operating Range (Most Severe)" - Every electronic control system sets a high limit for the expected operating range of the signal. The high limit includes over range signals. This could be a high temperature. A sensor that is still operating but sending a signal above the expected limit will cause a FMI 00 to be activated. An FMI 00 is activated when the condition is a Level 3 condition (most severe).Some of the conditions that can cause the FMI 00 diagnostic code to be activated are:
The medium or component that is being monitored is above the normal range.
The signal is shorted to the another voltage source.
The sensor needs to be calibrated.
An ECM has failed. This is unlikely.FMI 01 "Data Valid But Below Normal Operating Range" - Every electronic control system sets a low limit for the expected operating range of the signal. The limit includes signals that are under the lower limit. The low signal could be the oil pressure signal. The sensor is still working but sending a signal below the expected limit will cause a FMI 01 to be activated. An FMI 01 is activated when the condition is a Level 3 condition (most severe).Some of the conditions that can cause the FMI 01 diagnostic code to be activated are:
The medium or component that is being monitored is above the normal range.
Poor connections in the circuit.
The sensor has failed.
An ECM has failed. This is unlikely.FMI 02 "Data erratic, intermittent or incorrect" - The signal from a component is present. The control that reads the diagnostic information can not read the signal properly. The signal appears to be gone, unstable or invalid. The data can be correct or incorrect intermittently. Also, this condition relates to communication between controls. This is an example of communication between controls. When the monitoring system is looking for the engine speed from the Engine ECM over the CAT Data Link.Some of the conditions that can cause the FMI 02 diagnostic code to be activated are:
There is a poor connection in the circuit.
The signal is intermittent or erratic.
The software has been changed.
The signal is receiving interference from another circuit.
The signal is out of the range.
An ECM has failed. This is unlikely.FMI 03 "Voltage Above Normal" - The component or system voltage is higher than the limit. An FMI 03 most often relates to a signal circuit.Some of the conditions that could cause a FMI 03 diagnostic code to be activated are listed below.
Loss of power supply.
A open circuit or a bad connection.
A short to another voltage source.
The sensor or the switch has failed.
An ECM has failed. This is unlikely.FMI 04 "Voltage Below Normal" - The component or system voltage is lower than the limit. An FMI 04 diagnostic code most often relates to a power supply circuit.Conditions that could cause a FMI 04 diagnostic code are listed below.
The circuit is shorted to a ground source.
The circuit is open or has a poor connection.
The ground
FMI 00 "Data Valid But Above Normal Operating Range (Most Severe)" - Every electronic control system sets a high limit for the expected operating range of the signal. The high limit includes over range signals. This could be a high temperature. A sensor that is still operating but sending a signal above the expected limit will cause a FMI 00 to be activated. An FMI 00 is activated when the condition is a Level 3 condition (most severe).Some of the conditions that can cause the FMI 00 diagnostic code to be activated are:
The medium or component that is being monitored is above the normal range.
The signal is shorted to the another voltage source.
The sensor needs to be calibrated.
An ECM has failed. This is unlikely.FMI 01 "Data Valid But Below Normal Operating Range" - Every electronic control system sets a low limit for the expected operating range of the signal. The limit includes signals that are under the lower limit. The low signal could be the oil pressure signal. The sensor is still working but sending a signal below the expected limit will cause a FMI 01 to be activated. An FMI 01 is activated when the condition is a Level 3 condition (most severe).Some of the conditions that can cause the FMI 01 diagnostic code to be activated are:
The medium or component that is being monitored is above the normal range.
Poor connections in the circuit.
The sensor has failed.
An ECM has failed. This is unlikely.FMI 02 "Data erratic, intermittent or incorrect" - The signal from a component is present. The control that reads the diagnostic information can not read the signal properly. The signal appears to be gone, unstable or invalid. The data can be correct or incorrect intermittently. Also, this condition relates to communication between controls. This is an example of communication between controls. When the monitoring system is looking for the engine speed from the Engine ECM over the CAT Data Link.Some of the conditions that can cause the FMI 02 diagnostic code to be activated are:
There is a poor connection in the circuit.
The signal is intermittent or erratic.
The software has been changed.
The signal is receiving interference from another circuit.
The signal is out of the range.
An ECM has failed. This is unlikely.FMI 03 "Voltage Above Normal" - The component or system voltage is higher than the limit. An FMI 03 most often relates to a signal circuit.Some of the conditions that could cause a FMI 03 diagnostic code to be activated are listed below.
Loss of power supply.
A open circuit or a bad connection.
A short to another voltage source.
The sensor or the switch has failed.
An ECM has failed. This is unlikely.FMI 04 "Voltage Below Normal" - The component or system voltage is lower than the limit. An FMI 04 diagnostic code most often relates to a power supply circuit.Conditions that could cause a FMI 04 diagnostic code are listed below.
The circuit is shorted to a ground source.
The circuit is open or has a poor connection.
The ground
Cat SIS web machinery list:
Parts kit Caterpillar catalog:
2101330
KIT-SEAL
M313C, M313D, M315C, M315D, M315D 2, M316C, M316D, M317D 2, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH
M313C, M313D, M315C, M315D, M315D 2, M316C, M316D, M317D 2, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH
2580500
KIT-SEAL
M316C, M316D, M322C, M322D, M322D MH, M325C MH, M325D MH
M316C, M316D, M322C, M322D, M322D MH, M325C MH, M325D MH
2605316
KIT-SEAL
M315C, M315D, M316C, M316D, M317D 2
M315C, M315D, M316C, M316D, M317D 2
2042800
KIT-SEAL
318C, 319C, 320C, 320C FM, 320D, 320D FM, 320D L, 320D LRR, 320D RR, 320D2, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321C, 321D LCR, 322C, 322C FM, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D, 32...
318C, 319C, 320C, 320C FM, 320D, 320D FM, 320D L, 320D LRR, 320D RR, 320D2, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321C, 321D LCR, 322C, 322C FM, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D, 32...
2502503
KIT-SEAL
318C, 319C, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 321C, 321D LCR, 322C, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 3...
318C, 319C, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 321C, 321D LCR, 322C, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 3...
2366368
KIT-SEAL
318C, 319C, 319D, 319D L, 319D LN, 320B, 320C, 325B L, 325C, 325D, 329D L, 330B L, 330C, 345B II, 345B L, M322C, M322D, M322D MH
318C, 319C, 319D, 319D L, 319D LN, 320B, 320C, 325B L, 325C, 325D, 329D L, 330B L, 330C, 345B II, 345B L, M322C, M322D, M322D MH
2868866
KIT-GLASS
312C, 312D, 315C, 315D L, 319C, 319D, 320C, 322C, 323D L, 323D LN, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 329D L, 330C, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D L, 336D LN, 345C, 345C L, 345D,...
312C, 312D, 315C, 315D L, 319C, 319D, 320C, 322C, 323D L, 323D LN, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 329D L, 330C, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D L, 336D LN, 345C, 345C L, 345D,...
2868867
KIT-GLASS
312C, 312D, 315C, 315D L, 319C, 319D, 320C, 322C, 323D L, 323D LN, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 329D L, 330C, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D L, 336D LN, 345C, 345C L, 345D,...
312C, 312D, 315C, 315D L, 319C, 319D, 320C, 322C, 323D L, 323D LN, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 329D L, 330C, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D L, 336D LN, 345C, 345C L, 345D,...
1884176
KIT-SEAL
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 324E, 324E L, 324E LN, 325C, 325C FM, 325D, 325D FM, 325D FM LL, 325D L, 325D M...
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 324E, 324E L, 324E LN, 325C, 325C FM, 325D, 325D FM, 325D FM LL, 325D L, 325D M...
2159985
KIT-SEAL
1390, 320B, 320C, 322B LN, 322C, 325C, 325C FM, 325D, 325D FM, 325D L, 330C, 330C MH, 330D L, 330D MH, 336D LN, 345B II, 345C L, 365B, 365B II, 365C, 365C L, 385B, 385C L, 541, 551, 552, M322C, M322D,...
1390, 320B, 320C, 322B LN, 322C, 325C, 325C FM, 325D, 325D FM, 325D L, 330C, 330C MH, 330D L, 330D MH, 336D LN, 345B II, 345C L, 365B, 365B II, 365C, 365C L, 385B, 385C L, 541, 551, 552, M322C, M322D,...
1915619
KIT-SEAL
320C, 322C, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325C, 325C FM, 325C L, 325D, 325D L, 329D, 329D L, 329E, 330C, 330C FM, 330C L, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D2 L...
320C, 322C, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325C, 325C FM, 325C L, 325D, 325D L, 329D, 329D L, 329E, 330C, 330C FM, 330C L, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D2 L...
2042721
KIT-SEAL
330C, 345B II, 345B L, 350, M325C MH, M325D L MH
330C, 345B II, 345B L, 350, M325C MH, M325D L MH
3375862
KIT-GLASS
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH, MH3037, MH3049, MH3059
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH, MH3037, MH3049, MH3059
3375861
KIT-GLASS
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH, MH3037, MH3049, MH3059
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH, MH3037, MH3049, MH3059
3045419
KIT-PARTS
M313D, M315D, M315D 2, M316D, M317D 2, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH
M313D, M315D, M315D 2, M316D, M317D 2, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH
3045427
KIT-HOSE
M313D, M315D, M315D 2, M316D, M317D 2, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH
M313D, M315D, M315D 2, M316D, M317D 2, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH
3045426
KIT-MODULE
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH
3045425
KIT-HARNESS
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH
3399572
KIT-SEAL
M318D MH, M322D MH
M318D MH, M322D MH
3751288
KIT-SEAL
M318D MH, M322C, M322D, M322D MH
M318D MH, M322C, M322D, M322D MH
3081185
KIT-SEAL
M318D MH, M322D MH
M318D MH, M322D MH
3164212
KIT-SEAL
M318D MH, M322D MH
M318D MH, M322D MH
3532990
KIT-SEAL
M318D MH, M322D, M322D MH, M325D L MH, M325D MH
M318D MH, M322D, M322D MH, M325D L MH, M325D MH
3375864
KIT-SEAL
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH, MH3037, MH3049, MH3059
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH, M325D L MH, M325D MH, MH3037, MH3049, MH3059