Information:

Lead Numbering
The Wye Configurations and the Delta Configurations are the most common generator lead connections. The following three-phase connection diagrams illustrate the proper connection and lead identification.The leads are numbered clockwise from the top and from the outside inward. The diagrams that are contained in the "Wye Configuration Diagrams" section show lead numbering for the six lead generators and for the 12 lead generators. The diagrams contained in the "Delta Configuration Diagrams" section show lead numbering for the six lead generators and for the 12 lead generators.Wye Configuration Diagrams
6 Lead
Illustration 1 g00611486
6 Lead Wye Configuration
Terminals T4, T5, and T6 become a neutral connection when the terminals are tied together.
12 Lead
Illustration 2 g00661863
12 Lead Wye Configuration - High Voltage
Terminals T10, T11, and T12 become neutral connection when the terminals are tied together.
Illustration 3 g00611608
12 Lead Wye Configuration - Low Voltage
Terminals T10, T11, and T12 become neutral connection when the terminals are tied together.
Delta Configuration Diagrams
6 Lead
Illustration 4 g00669319
6 Lead Delta Configuration
12 Lead
Illustration 5 g00669312
12 Lead Delta Configuration
Terminals T6 and T9 become the neutral connection when the terminals are tied together and grounded. This configuration reflects the terminal T2 and T10 connection as the high phase.
Grounding the Frame
In any generator set installation, the frame of the generator is positively connected to an earth ground. This connection is the first connection that is made at the installation. This connection is the last connection that should be removed. If the generator set is on flexible pads or on resilient pads, the ground connection must be flexible. This configuration will avoid possible breakage in later operation.Ground connection cable or ground connection straps should have at least the current carrying capacity of the largest line lead to the connected load. Joints in cables or in straps must be clean, free of electrical resistance, and protected from possible oxidation. Bolted ground connection joints eventually oxidize. The joints are frequent sources of radio frequency interference (RFI). Silver soldered joints and bolted joints are electrically and mechanically sound.Neutral Connections
The generators with Wye Configuration usually have the neutral grounded when the generator is installed. However, there are some cases when definite measures should be taken in order to prevent grounds on the load side. The purpose of the grounding of the neutral is to prevent load side equipment damage.If the neutral wire is grounded and one of the phase leads becomes grounded, the excessive current will open a load circuit breaker. The excessive current will also collapse the generator voltage. The result depends on the following items: particular generator electrical characteristics, type of fault and trip rating of the circuit breaker. An undervoltage device may be required in order to provide an adequate short circuit protection.There are some instances in which grounding the neutral wire is undesirable. In other applications, having an ungrounded neutral lead is acceptable. Definite measures should be taken in such applications in order to prevent grounds to the phase leads. An example of such measures is ground fault protective circuits. Ground fault protection requires that the entire group of

Caterpillar parts catalog:

Caterpillar parts catalog
930M Small Wheel Loader HEY00001-UP (MACHINE) POWERED BY C7.1 Engine
930K ADL (Air Deployable Loader) HEG00001-UP (MACHINE) POWERED BY C7.1 Engine
924K Wheel Loader PWR00001-UP (MACHINE) POWERED BY C6.6 Engine
930K Wheel Loader RHN00001-UP (MACHINE) POWERED BY C6.6 Engine
938K Wheel Loader SWL00001-UP (MACHINE) POWERED BY C6.6 Engine
924K Small Wheel Loader ENC00001-UP (MACHINE) POWERED BY C7.1 Engine
924K Small Wheel Loader HJF00001-UP (MACHINE) POWERED BY C7.1 Engine
930K Small Wheel Loader DYB00001-UP (MACHINE) POWERED BY C7.1 Engine
930K Small Wheel Loader EYE00001-UP (MACHINE) POWERED BY C7.1 Engine
938K Small Wheel Loader HFW00001-UP (MACHINE) POWERED BY C7.1 Engine
938K Small Wheel Loader XXT00001-UP (MACHINE) POWERED BY C7.1 Engine
930K Military Fork Lift TNY00001-UP (MACHINE)
926M Small Wheel Loader LTE00001-UP (MACHINE) POWERED BY C7.1 Engine
930M Small Wheel Loader KTG00001-UP (MACHINE) POWERED BY C7.1 Engine
938M Small Wheel Loader J3R00001-UP (MACHINE) POWERED BY C7.1 Engine
938K Small Wheel Loader W8K00001-UP (MACHINE) POWERED BY C7.1 Engine
930K Small Wheel Loader FRK00001-UP (MACHINE) POWERED BY C7.1 Engine
924K Small Wheel Loader SNZ00001-UP (MACHINE) POWERED BY C7.1 Engine
938K Small Wheel Loader REP00001-UP (MACHINE) POWERED BY C7.1 Engine
924K Small Wheel Loader KW400001-UP (MACHINE) POWERED BY C7.1 Engine
930K Small Wheel Loader P3K00001-UP (MACHINE) POWERED BY C7.1 Engine


Parts kit Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.