4441754 KIT-RETAINER Caterpillar parts
Rating:
Alternative (cross code) number:
CA4441754
444-1754
4441754
CA4441754
444-1754
4441754
Weight: 4 pounds 2 kg.
Information:
This diagnostic code is associated with the wheel lean left solenoid. The FMI 13 diagnostic code is activated when the ECM detects that the solenoid needs calibration.The Implement ECM provides a PWM output signal to the solenoid in order to provide proportional control of the solenoid. The ECM will vary the electrical current of the PWM output signal based on the input command that is received from the wheel lean control position sensor that is located in the left joystick assembly.Note: Before performing this procedure, verify that no other active CID 2173 diagnostic codes exist for the solenoid. If any other diagnostic codes are active for the solenoid, correct the problem before performing this procedure. Test Step 1. CALIBRATION
Perform the calibration procedure for the solenoid. Refer to Testing and Adjusting, "Calibration" section of this manual for the correct calibration procedure. Expected Result:The calibration procedure was performed successfully.Results:
YES - The calibration procedure was performed successfully. Resume normal machine operation.STOP
NO - The calibration was not successful.Repair: Repeat the calibration procedure for the solenoid. If the second calibration procedure is not successful, replace the solenoid. After solenoid replacement, refer to Testing and Adjusting, "Calibration" section of this manual for the correct calibration procedure. If the problem is still present after replacement and calibration of the new solenoid, the ECM may have failed.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found, replace the ECM. Refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
Perform the calibration procedure for the solenoid. Refer to Testing and Adjusting, "Calibration" section of this manual for the correct calibration procedure. Expected Result:The calibration procedure was performed successfully.Results:
YES - The calibration procedure was performed successfully. Resume normal machine operation.STOP
NO - The calibration was not successful.Repair: Repeat the calibration procedure for the solenoid. If the second calibration procedure is not successful, replace the solenoid. After solenoid replacement, refer to Testing and Adjusting, "Calibration" section of this manual for the correct calibration procedure. If the problem is still present after replacement and calibration of the new solenoid, the ECM may have failed.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found, replace the ECM. Refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
Caterpillar parts catalog:
Parts kit Caterpillar catalog:
4441729
KIT-RETAINER
Caterpillar
Caterpillar
4438552
KIT-HOSE
Caterpillar
Caterpillar
4438546
KIT-HOSE
Caterpillar
Caterpillar
4417619
KIT-COMPENSATOR
Caterpillar
Caterpillar
4417616
KIT-COMPENSATOR
Caterpillar
Caterpillar
4417583
KIT-ORIFICE
Caterpillar
Caterpillar
4513603
KIT-HOUSING
Caterpillar
Caterpillar
4512596
KIT-MONITOR
Caterpillar
Caterpillar
4505864
KIT-SEAL
Caterpillar
Caterpillar
4505863
KIT-SEAL
Caterpillar
Caterpillar
4491640
KIT-SEAL
Caterpillar
Caterpillar
4478022
KIT-SEAL
Caterpillar
Caterpillar