Information:
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below. Problem
The generator set engines that are listed above may receive an "Unexpected Engine Shutdown". The fault code is 1383-11. When the run signal is applied to the generator set the following actions occur:
The engine will crank and the engine will start.
The engine will run momentarily and the engine will shut down.
The EMCP3 displays the 1383-11 fault code.
No other alarms or fault codes are generated.The default settings for the 272-2223 Governor Actuator Gp may trigger a command for "zero" fuel. After the command is issued, the EMCP3 determines that the initial rpm reading is excessive. The EMCP3 issues the "Unexpected Engine Shutdown" and the 1383-11 fault code is generated.Note: This problem occurs more frequently in engines that are used for standby operations because these engines sit without being run for extended periods. Solution
The default settings that are set in the 272-2223 Governor Actuator Gp need to be modified. Modify the following values in order to resolve the problem:
"Acceleration Ramp Rate:"
"Overspeed Threshold:"Perform the following steps in order to modify the values:
Attach the 262-8392 Wiring Harness to the governor.
Connect the software to the governor.
Select "File".
Illustration 1 g01675258
Select "Open Configuration".The "L-Series Service Tool" window opens. You are asked to enter a password.
Enter the following password:.Lseries01Note: The characters that are entered will be replaced by a series of asterisks.
Select the "OK" button. The "Configuration File Editor" window opens.
Illustration 2 g01675259
Select the "Setpoint" tab.
Illustration 3 g01675260
Decrease the "Acceleration Ramp Rate:" from the default value of 1000.0 rpm/sec to a new value of 500 rpm/sec.
Illustration 4 g01675261
Select the "Control" tab.
Illustration 5 g01675262
Increase the "Overspeed Threshold:" from the default value of 2000 rpm to a new value of 2300 rpm. This field is in the "Error Detection" section of the window.
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below. Problem
The generator set engines that are listed above may receive an "Unexpected Engine Shutdown". The fault code is 1383-11. When the run signal is applied to the generator set the following actions occur:
The engine will crank and the engine will start.
The engine will run momentarily and the engine will shut down.
The EMCP3 displays the 1383-11 fault code.
No other alarms or fault codes are generated.The default settings for the 272-2223 Governor Actuator Gp may trigger a command for "zero" fuel. After the command is issued, the EMCP3 determines that the initial rpm reading is excessive. The EMCP3 issues the "Unexpected Engine Shutdown" and the 1383-11 fault code is generated.Note: This problem occurs more frequently in engines that are used for standby operations because these engines sit without being run for extended periods. Solution
The default settings that are set in the 272-2223 Governor Actuator Gp need to be modified. Modify the following values in order to resolve the problem:
"Acceleration Ramp Rate:"
"Overspeed Threshold:"Perform the following steps in order to modify the values:
Attach the 262-8392 Wiring Harness to the governor.
Connect the software to the governor.
Select "File".
Illustration 1 g01675258
Select "Open Configuration".The "L-Series Service Tool" window opens. You are asked to enter a password.
Enter the following password:.Lseries01Note: The characters that are entered will be replaced by a series of asterisks.
Select the "OK" button. The "Configuration File Editor" window opens.
Illustration 2 g01675259
Select the "Setpoint" tab.
Illustration 3 g01675260
Decrease the "Acceleration Ramp Rate:" from the default value of 1000.0 rpm/sec to a new value of 500 rpm/sec.
Illustration 4 g01675261
Select the "Control" tab.
Illustration 5 g01675262
Increase the "Overspeed Threshold:" from the default value of 2000 rpm to a new value of 2300 rpm. This field is in the "Error Detection" section of the window.
Parts kit Caterpillar catalog:
4472197
KIT-
Caterpillar
Caterpillar
4471529
KIT-XMSN TCU
Caterpillar
Caterpillar
4471401
KIT-GASKET (T)
Caterpillar
Caterpillar
4470917
KIT-REPAIR
Caterpillar
Caterpillar
4470486
KIT-ELHYD
Caterpillar
Caterpillar
4470483
KIT-JOYSTICK
Caterpillar
Caterpillar
4477676
KIT-MONITOR
Caterpillar
Caterpillar
4474895
KIT-COUPLER
Caterpillar
Caterpillar
4473234
KIT-
Caterpillar
Caterpillar
4473100
KIT-COMPRESSOR
Caterpillar
Caterpillar
4473095
KIT-VALVE
Caterpillar
Caterpillar
4472218
KIT-SEAL
Caterpillar
Caterpillar