AVSPARE.COM
parts catalog

KIT- 4615140 - Caterpillar


4615140 KIT- Caterpillar parts
Rating:
86
Alternative (cross code) number:
CA4615140
461-5140
4615140
Caterpillar 4615140 KIT-
Weight: 2 pounds 1 kg.

Buy KIT- 4615140 Caterpillar genuine, new aftermarket tractor parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$256.72

22 May 2025
0.0[0.00] pounds
Amazon.com
Eibach 4615140
Eibach 2006-2009 for Kia Rio - 1 in. Front/.800 in. Rear Drop || Part number: 4615140 || Fit type: Vehicle Specific || Package Weight: 26.0 pounds
$260.31

01 May 2025
0.0[0.00] Pounds
Amazon.com
Eibach 4615140
Eibach 2006-2009 for Kia Rio - 1 in. Front/.800 in. Rear Drop || Part number: 4615140 || Fit type: Vehicle Specific || Package Weight: 26.0 pounds
$200.33

02 Mar 2025
0.0[0.00] pounds
Amazon.com
Eibach 4615140
Eibach 2006-2009 for Kia Rio - 1 in. Front/.800 in. Rear Drop || Part number: 4615140 || Fit type: Vehicle Specific || Package Weight: 26.0 pounds
  For full view, you need register

Information:


To replace the expansion valve, use the procedure that follows. Refer to Service Manual, SENR3334, "Troubleshooting Heating and Air Conditioning Control System" before service work is performed on the air conditioning system.
Recover the refrigerant.Note: Cap all disconnected lines and hoses.
Remove the insulation and the clip. The insulation and the clip hold the sensing bulb to the evaporator outlet pipe.
Disconnect the sensing line for pressure from the evaporator outlet pipe.
Loosen and remove the two connections at the expansion valve. Remove the expansion valve.Note: Check the O-ring seals. The seals must be in good condition and the seals must be properly lubricated with the correct refrigerant oil before assembly.
Install the expansion valve for replacement and tighten the two connections.
Tighten the pressure sensing connection on the evaporator outlet pipe.
Use a 8P-6355 Clip to hold the sensing bulb onto the evaporator outlet pipe. The sensing bulb should be as close to the coil as possible. The bulb should be upstream of the pressure sensing connection on the evaporator outlet pipe. The 5P-7070 Insulation should be wrapped tightly around the clip, the sensing bulb and the outlet pipe. There should be no insulation between the bulb and the outlet pipe.
Tighten all the connections correctly.
Evacuate the system. Refer to the Service Manual, SENR3334, "Refrigerant System - Evacuate" section in testing and adjusting.
Charge the system with the correct amount of refrigerant by weight. Refer to the Service Manual, SENR3334, "Refrigerant System - Charge" section in testing and adjusting.


Parts kit Caterpillar catalog:

4613387 KIT-
Caterpillar
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.