Information:
Illustration 1 g01360292
Schematic of the Left Auger Forward SolenoidThis diagnostic code is associated with the Left Auger Forward Solenoid. The FMI 03 means that the Machine ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.Note: The Machine ECM is located inside the Center Console.Conditions that could cause this diagnostic code to be activated are:
The energize circuit of the solenoid is shorted to another voltage source.
The ECM has failed. This situation is unlikely.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. System Response:When this diagnostic code is active, the following occurs:
Left auger will run at full forward speed.
Operator station fault lamp is active., operator station fault lamp activeTest Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness at the solenoid for the Left Auger Forward hydraulic valve. Disconnect the machine harness connectors J1 and J2 from the ECM.
At the machine harness ECM connectors, measure the resistance from contact J1-58 (wire A912-PU) to all of the other contacts that are used in the J1 and J2 connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.
NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. Repair: The short is between wire A912-PU and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Troubleshooting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.STOPTest Step 2. CHECK THE OPERATION OF THE ECMThe disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
At the machine harness connector J1 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire A912-PU and socket at contact J1-58 from the harness connector.
Reconnect the machine harness J1 and J2 connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active CID 1735 FMI 03 diagnostic code.Expected Result:The CID 1735 FMI 03 diagnostic code is no longer active. A CID 1735 FMI 05 diagnostic code
Parts kit Caterpillar catalog:
5303409
KIT-ARM
Caterpillar
Caterpillar
5303366
KIT-PART
Caterpillar
Caterpillar
5303364
KIT-SEAL
Caterpillar
Caterpillar
5303353
KIT-SEAL
Caterpillar
Caterpillar
5303351
KIT-SEAL
Caterpillar
Caterpillar
5303344
KIT-SEAL
Caterpillar
Caterpillar
5303499
KIT-SEAL
Caterpillar
Caterpillar
5303484
KIT-HOSE
Caterpillar
Caterpillar
5303471
KIT-VALVE
Caterpillar
Caterpillar
5303464
KIT-FILTER
Caterpillar
Caterpillar
5303458
KIT-VALVE
Caterpillar
Caterpillar
5303455
KIT-VALVE
Caterpillar
Caterpillar