Pressing the A-Stop button and Test button at the Test Station fails to register the device.Test Step 1. CHECK THE POWER LEVEL OF THE A-STOP DEVICE.Verify that the handheld A-Stop is charged.Results:
OK - The Test/Power Indicator blinks periodically and the Red Battery charge indicator is not illuminated.
Proceed to Test Step 2.
NOT OK - The Test/Power Indicator does not blink or the Red Battery charge indicator is illuminated. Charge the handheld A-Stop device.STOPTest Step 2. PERFORM A FIELD TEST OF THE A-STOP.Refer to the Operations and Maintenance Manual, M0069882, "Autonomous Stop (A-Stop)".Results:
OK - The autonomous machine responds to the test properly.
Proceed to Test Step 3.
NOT OK - The machine does not respond. The A-Stop is not functioning correctly. Refer to "A-Stop Fails to Activate" to troubleshoot the A-Stop.STOPTest Step 3. VERIFY THE A-STOP TEST STATION IS CORRECTLY CONNECTED.Refer to the Special Instruction, M0069890, "Installation and Configuration Procedure for an Autonomous Stop (A-Stop) System" guide to verify that the A-Stop Test Station is plugged in and has a correct Ethernet connection.Results:
OK - The Test Station is connected correctly.
Proceed to Test Step 4.
NOT OK - The Test Station is not correctly connected. Resolve the connection issues.STOPTest Step 4. INSPECT THE A-STOP TEST STATION ANTENNA AND ANTENNA WIRING.Refer to the Special Instruction, M0069890, "Installation and Configuration Procedure for an Autonomous Stop (A-Stop) System" guide to verify that the A-Stop Test Station antenna is correctly connected to the Test Station.Results:
OK - The Test Station antenna is connected correctly.
Proceed to Test Step 5.
NOT OK - The Test Station antenna is not correctly connected. Resolve the connection issues.STOPTest Step 5. VERIFY THAT THE CORRECT HIM SOFTWARE VERSION IS INSTALLED.Refer to Systems Operation, KENR8678, "Setup and Configuration for Health Interface Module (HIM)" and check health interface module GUI to determine the version of software that is installed.Results:
OK - The correct version is installed. Contact Caterpillar Technical Support.STOP
NOT OK - The correct version is not installed. Refer to the Setup and Configuration Guide to flash the correct version.STOP
OK - The Test/Power Indicator blinks periodically and the Red Battery charge indicator is not illuminated.
Proceed to Test Step 2.
NOT OK - The Test/Power Indicator does not blink or the Red Battery charge indicator is illuminated. Charge the handheld A-Stop device.STOPTest Step 2. PERFORM A FIELD TEST OF THE A-STOP.Refer to the Operations and Maintenance Manual, M0069882, "Autonomous Stop (A-Stop)".Results:
OK - The autonomous machine responds to the test properly.
Proceed to Test Step 3.
NOT OK - The machine does not respond. The A-Stop is not functioning correctly. Refer to "A-Stop Fails to Activate" to troubleshoot the A-Stop.STOPTest Step 3. VERIFY THE A-STOP TEST STATION IS CORRECTLY CONNECTED.Refer to the Special Instruction, M0069890, "Installation and Configuration Procedure for an Autonomous Stop (A-Stop) System" guide to verify that the A-Stop Test Station is plugged in and has a correct Ethernet connection.Results:
OK - The Test Station is connected correctly.
Proceed to Test Step 4.
NOT OK - The Test Station is not correctly connected. Resolve the connection issues.STOPTest Step 4. INSPECT THE A-STOP TEST STATION ANTENNA AND ANTENNA WIRING.Refer to the Special Instruction, M0069890, "Installation and Configuration Procedure for an Autonomous Stop (A-Stop) System" guide to verify that the A-Stop Test Station antenna is correctly connected to the Test Station.Results:
OK - The Test Station antenna is connected correctly.
Proceed to Test Step 5.
NOT OK - The Test Station antenna is not correctly connected. Resolve the connection issues.STOPTest Step 5. VERIFY THAT THE CORRECT HIM SOFTWARE VERSION IS INSTALLED.Refer to Systems Operation, KENR8678, "Setup and Configuration for Health Interface Module (HIM)" and check health interface module GUI to determine the version of software that is installed.Results:
OK - The correct version is installed. Contact Caterpillar Technical Support.STOP
NOT OK - The correct version is not installed. Refer to the Setup and Configuration Guide to flash the correct version.STOP