AVSPARE.COM
parts catalog

LAMP 5425698 - Caterpillar


5425698 LAMP Caterpillar parts
Rating:
11
Alternative (cross code) number:
CA5425698
542-5698
5425698
Caterpillar 5425698 LAMP
Weight: 3 pounds 1 kg.

Buy LAMP 5425698 Caterpillar genuine, new aftermarket tractor parts with delivery

Number on catalog scheme: 7
  For full view, you need register

Information:


Illustration 1 g00530281
System Schematic For Alarm Module (ALM)There are several possible causes when the indicators of the alarm module are flashing. Before performing the test procedure, review the following requirements for the alarm module.
Check The GSC+ For Diagnostic Codes. If a CID 333 FMI 03 or CID 333 FMI 04 diagnostic code is active or if the codes are contained in the fault log, perform those procedures first.
Verify The Number Of Modules. A maximum of three modules for the alarms can be connected to the GSC+ data link.
Verify That All Remote Modules Are Powered. If multiple modules are connected to a GSC+, ALL of the modules must be powered up. If a module is not powered and the +battery wire is disconnected or if the ground wire is disconnected, the wire on terminal 2 must be disconnected as well.
Verify The Length Of The Wire. The maximum length of the wires between the GSC+ and a remote annunciator is 304 m (1000 ft). Note: The actual length of the wire can be considerably longer than the physical distance between the two modules.
Check The Type Of Wire Or Cable On The Remote Modules. Three separate wires for the following connections are recommended for remote installations: +battery, battery negative and data for the alarm. Other wires for the switched inputs on a remote annunciator may also be required by the application. The wires should be size 16 AWG. Verify that the wire is NOT a shielded type. Verify that the wire does not have twisted conductors. This type of cable is not appropriate for this purpose. These types of cables usually have more capacitance than separate wires and the data from the GSC+ can be corrupted.
Verify The Methods Of Wiring. Each remote annunciator must have a separate set of three wires between it and the GSC+. Do NOT connect any wires directly between remote annunciators. The wires should NOT be in the same conduit as wires for AC voltage or other high voltage signals. Test Step 1. CHECK THE DATA CIRCUIT WIRE FOR AN OPEN
Clear the GSC+ Fault Log. See Systems Operation, "Fault Log Clearing OP4".
Turn the engine control switch (ECS) to OFF/RESET.
Temporarily connect terminal 1 to terminal 2 of the alarm module for a few seconds.
Temporarily connect terminal 7 to terminal 2 of the alarm module for a few seconds.Expected Result:The CID 333 FMI 03 and CID 333 FMI 04 diagnostic codes should be temporarily active while the faults are occurring. The CID 333 FMI 03 and the CID 333 FMI 04 diagnostic codes, should be contained in the

Caterpillar parts catalog:

Caterpillar parts catalog
M323F Roadrail Wheeled Excavators RH300001-UP (MACHINE) POWERED BY C4.4 Engine


Parts lamp Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.