Problem 5
The engine shutdown occurs after the engine runs for more than 3 minutes.
Check the overspeed setting on the electronic speed switch (ESS).
Observe the indicator lamp on the ESS.
Reset the air shutoff lever, if equipped.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The indicator lamp on the ESS is turned on.Overspeed is indicated as the cause of the engine shutdown. Press the "RESET" button of the ESS. Find the cause of the overspeed. Refer to Testing and Adjusting, "Overspeed Verification Test" and Testing and Adjusting, "Overspeed Calibration". If the overspeed is adjusted properly and the problem persists, check the shielded cable. Only the shield should be connected to terminal 2 on the ESS. STOP.
The indicator lamp is turned off.Go to Step 2.
Check the protection switches.
Remove the jumper that is between terminals (TS-9) and (TS-10) of the junction box.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The problem is in the oil pressure switches or the water temperature contactor switch. Go to Step 8 of "Problem 1".
The engine starts but engine shutdown occurs immediately.Go to Step 1 of "Problem 3".
The engine starts and the engine runs but engine shutdown occurs after the engine runs for more than 3 minutes.Go to Step 3.
The engine cranks but the engine does not start.Go to Step 1 of "Problem 1".
Check the start/stop switch.
Disconnect the wire in the junction box that connects terminal (SR1-85) of the slave relay (SR1) to terminal (TD-7) of the time delay relay (TD).
Disconnect the wire from terminal (TD-7) and insulate the exposed wire.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch has a short circuit or a wiring problem is causing a voltage at terminal (TD-7). Reconnect the wire to the terminal.
Check the start/stop switch.
Disconnect the wire that runs from the STOP position of terminal (SSS-6) to terminal (TD-6). Terminal (SSS-6) is on the start/stop switch.
Disconnect the wire at terminal (TD-7).
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch is faulty. Replace the switch. STOP.
Engine shutdown still occurs.Reconnect the wire to terminal (TD-7). Go to Step 5
Check the slave relay (SR1).
Disconnect the wire that connects terminal (TS-10) of the junction box to terminal (TD-6) of the time delay relay.
Disconnect the wire at terminal (TD-6).
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch is faulty. Replace the start/stop switch. STOP.
Engine shutdown still occurs.The contacts of SR1 periodically close. The problem may also be with the governor or the fuel supply to the engine. Refer to the Engine Service Manual. If a 2301A Electric Governor is used, the SR1 contacts may be opening. Refer to 2301A Electric Governor Service Manual, SENR3585. Test SR1. Refer to Testing and Adjusting, "Slave Relay Test".Problem 6
Engine shutdown does not occur
The engine shutdown occurs after the engine runs for more than 3 minutes.
Check the overspeed setting on the electronic speed switch (ESS).
Observe the indicator lamp on the ESS.
Reset the air shutoff lever, if equipped.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The indicator lamp on the ESS is turned on.Overspeed is indicated as the cause of the engine shutdown. Press the "RESET" button of the ESS. Find the cause of the overspeed. Refer to Testing and Adjusting, "Overspeed Verification Test" and Testing and Adjusting, "Overspeed Calibration". If the overspeed is adjusted properly and the problem persists, check the shielded cable. Only the shield should be connected to terminal 2 on the ESS. STOP.
The indicator lamp is turned off.Go to Step 2.
Check the protection switches.
Remove the jumper that is between terminals (TS-9) and (TS-10) of the junction box.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The problem is in the oil pressure switches or the water temperature contactor switch. Go to Step 8 of "Problem 1".
The engine starts but engine shutdown occurs immediately.Go to Step 1 of "Problem 3".
The engine starts and the engine runs but engine shutdown occurs after the engine runs for more than 3 minutes.Go to Step 3.
The engine cranks but the engine does not start.Go to Step 1 of "Problem 1".
Check the start/stop switch.
Disconnect the wire in the junction box that connects terminal (SR1-85) of the slave relay (SR1) to terminal (TD-7) of the time delay relay (TD).
Disconnect the wire from terminal (TD-7) and insulate the exposed wire.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch has a short circuit or a wiring problem is causing a voltage at terminal (TD-7). Reconnect the wire to the terminal.
Check the start/stop switch.
Disconnect the wire that runs from the STOP position of terminal (SSS-6) to terminal (TD-6). Terminal (SSS-6) is on the start/stop switch.
Disconnect the wire at terminal (TD-7).
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch is faulty. Replace the switch. STOP.
Engine shutdown still occurs.Reconnect the wire to terminal (TD-7). Go to Step 5
Check the slave relay (SR1).
Disconnect the wire that connects terminal (TS-10) of the junction box to terminal (TD-6) of the time delay relay.
Disconnect the wire at terminal (TD-6).
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch is faulty. Replace the start/stop switch. STOP.
Engine shutdown still occurs.The contacts of SR1 periodically close. The problem may also be with the governor or the fuel supply to the engine. Refer to the Engine Service Manual. If a 2301A Electric Governor is used, the SR1 contacts may be opening. Refer to 2301A Electric Governor Service Manual, SENR3585. Test SR1. Refer to Testing and Adjusting, "Slave Relay Test".Problem 6
Engine shutdown does not occur
Caterpillar parts catalog:
Parts latch Caterpillar catalog:
2591241
LATCH
973C, D6N
973C, D6N
2433605
LATCH AS
561N
561N
1803146
LATCH AS
D3G, D4G, D5G, D6G2 LGP, D6G2 XL, D7G, D7G2
D3G, D4G, D5G, D6G2 LGP, D6G2 XL, D7G, D7G2
1803145
LATCH AS-ROTARY
554, 564, 574B, D3G, D4G, D5G, D6G2 LGP, D6G2 XL, D7G, D7G2
554, 564, 574B, D3G, D4G, D5G, D6G2 LGP, D6G2 XL, D7G, D7G2
1803154
LATCH AS-DOOR
D3G, D3K XL, D3K2 LGP, D4G, D4K XL, D4K2 XL, D5G, D5K LGP, D5K2 XL, D6G, D6G2 LGP, D6G2 XL, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, D7G2
D3G, D3K XL, D3K2 LGP, D4G, D4K XL, D4K2 XL, D5G, D5K LGP, D5K2 XL, D6G, D6G2 LGP, D6G2 XL, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, D7G2
1803153
LATCH AS-DOOR
D3G, D3K XL, D3K2 LGP, D4G, D4K XL, D4K2 XL, D5G, D5K LGP, D5K2 XL, D6G, D6G2 LGP, D6G2 XL, D6K, D6K LGP, D6K2, D6K2 LGP, D7G2
D3G, D3K XL, D3K2 LGP, D4G, D4K XL, D4K2 XL, D5G, D5K LGP, D5K2 XL, D6G, D6G2 LGP, D6G2 XL, D6K, D6K LGP, D6K2, D6K2 LGP, D7G2
2679252
LATCH AS
D6K, D6K LGP, PL61
D6K, D6K LGP, PL61
2643010
LATCH AS
D3K XL, D3K2 LGP, D4K XL, D4K2 XL, D5K LGP, D5K2 XL, D6K LGP, D6K2, D6K2 LGP
D3K XL, D3K2 LGP, D4K XL, D4K2 XL, D5K LGP, D5K2 XL, D6K LGP, D6K2, D6K2 LGP
3262662
LATCH
D6K, D6K LGP, D6K XL, PL61
D6K, D6K LGP, D6K XL, PL61
2885422
LATCH
D6K, D6K LGP, PL61
D6K, D6K LGP, PL61
2839900
LATCH AS
D3K XL, D4K XL, D5K LGP, D6K, D6K LGP
D3K XL, D4K XL, D5K LGP, D6K, D6K LGP
3255687
LATCH AS
583T, 587R, 587T, 844K, 854K, 990K, 992K, 993K, 994H, D10T, D10T2, D11T, D6T LGP, D6T LGPPAT, D8T, D9T, PL83, PL87
583T, 587R, 587T, 844K, 854K, 990K, 992K, 993K, 994H, D10T, D10T2, D11T, D6T LGP, D6T LGPPAT, D8T, D9T, PL83, PL87