6V1156 LATCH (L.H.) Caterpillar parts
955L, 977L, 980C, D10, D4E, D5B, D6D
Rating:
Alternative (cross code) number:
CA6V1156
6V-1156
6V1156
CA6V1156
6V-1156
6V1156
Weight: 0.70 pounds 0 kg.
TRACK LOADER, WHEEL LOADER,
Compatible equipment models: 6V1156:
Information:
Cat Monitoring System
The engine is equipped with a programmable Caterpillar Monitoring System. The Electronic Control Module (ECM) monitors the operating parameters of the engine. The ECM can initiate responses if a specific engine parameter exceeds an acceptable range. Three possible responses may be available for each parameter: "", "DERATE" and "SHUTDOWN". Some of the responses are not available for some of the parameters. An ET service tool is used to perform the following activities:
Select the available responses.
Program the level for monitoring.
Program delay times for each response.The default settings for the parameters are programmed at the factory. To accommodate unique applications and sites, the parameters may be reprogrammed with an ET service tool.The screens of the ET service tool provide guidance for the programming. The following options can be programmed "ON" or "OFF": , "", "DERATE" and "SHUTDOWN".The screens of the ET service tool also provide guidance for changing setpoints. For information on programming the Caterpillar Monitoring System, use the appropriate ET service tool and see the Service Manual, "Troubleshooting" module.The Cat Monitoring System is enabled after the engine is started. When the engine rpm exceeds 50 rpm below low idle, the ECM begins checking parameters. The ECM monitors the parameters in order to determine if the parameters exceed the setpoints.If the monitoring system initiates a warning, a deration, or a shutdown, the event is logged into the ECM. This event occurs if the parameter is programmed "OFF". If a setpoint for a parameter is exceeded, the event will be logged.Any failure of a sensor will result in disabling the corresponding portion of the monitoring system. The failure of a sensor will cause an "ACTIVE" diagnostic code for the sensor.The derating is cumulative. For example, a derating of 5 percent followed by a derating of 2 percent results in a total derating of 7 percent. If the conditions that cause the derating are not corrected, the derating will continue.Default Settings for the Cat Monitoring System
Derate - Reduction of engine horsepower in response to an abnormal operating condition.Setpoint - A specific value which can activate the following responses: warning, deration and shutdown. The setpoint can be a pressure, a speed, a temperature, or a voltage.Hysteresis - The change in the signal from a sensor that is tolerated by the ECM. Hysteresis is the difference between the setpoint that activates a response and the value that deactivates the response. For example, a warning for low voltage can activate if a value below 20 V is detected by the ECM. The voltage must rise to 22 V in order to clear the warning. The hysteresis is the 2 V that are above the 20 V.For additional information on operating parameters, refer to Service Manual, KENR5476.
The engine is equipped with a programmable Caterpillar Monitoring System. The Electronic Control Module (ECM) monitors the operating parameters of the engine. The ECM can initiate responses if a specific engine parameter exceeds an acceptable range. Three possible responses may be available for each parameter: "", "DERATE" and "SHUTDOWN". Some of the responses are not available for some of the parameters. An ET service tool is used to perform the following activities:
Select the available responses.
Program the level for monitoring.
Program delay times for each response.The default settings for the parameters are programmed at the factory. To accommodate unique applications and sites, the parameters may be reprogrammed with an ET service tool.The screens of the ET service tool provide guidance for the programming. The following options can be programmed "ON" or "OFF": , "", "DERATE" and "SHUTDOWN".The screens of the ET service tool also provide guidance for changing setpoints. For information on programming the Caterpillar Monitoring System, use the appropriate ET service tool and see the Service Manual, "Troubleshooting" module.The Cat Monitoring System is enabled after the engine is started. When the engine rpm exceeds 50 rpm below low idle, the ECM begins checking parameters. The ECM monitors the parameters in order to determine if the parameters exceed the setpoints.If the monitoring system initiates a warning, a deration, or a shutdown, the event is logged into the ECM. This event occurs if the parameter is programmed "OFF". If a setpoint for a parameter is exceeded, the event will be logged.Any failure of a sensor will result in disabling the corresponding portion of the monitoring system. The failure of a sensor will cause an "ACTIVE" diagnostic code for the sensor.The derating is cumulative. For example, a derating of 5 percent followed by a derating of 2 percent results in a total derating of 7 percent. If the conditions that cause the derating are not corrected, the derating will continue.Default Settings for the Cat Monitoring System
Derate - Reduction of engine horsepower in response to an abnormal operating condition.Setpoint - A specific value which can activate the following responses: warning, deration and shutdown. The setpoint can be a pressure, a speed, a temperature, or a voltage.Hysteresis - The change in the signal from a sensor that is tolerated by the ECM. Hysteresis is the difference between the setpoint that activates a response and the value that deactivates the response. For example, a warning for low voltage can activate if a value below 20 V is detected by the ECM. The voltage must rise to 22 V in order to clear the warning. The hysteresis is the 2 V that are above the 20 V.For additional information on operating parameters, refer to Service Manual, KENR5476.
Cat SIS web machinery list:
Parts latch Caterpillar catalog:
6V1157
LATCH (R.H.)
955L, 977L, D10, D4E, D5B, D6D
955L, 977L, D10, D4E, D5B, D6D
5P5828
LATCH (L.H.)
768C, 769C, D4E, D6D
768C, 769C, D4E, D6D
7G0247
LATCH
910, 943, 953, 955L, 963, 973
910, 943, 953, 955L, 963, 973
7G2355
LATCH
977L
977L
8P9675
LATCH ASSEM.
955L, 977L, 983B
955L, 977L, 983B
9P8460
LATCH
D4E, D6D
D4E, D6D
9D5194
LATCH (R.H.)
120G, 12G, 130G, 140G, 14G, 16G, 977L
120G, 12G, 130G, 140G, 14G, 16G, 977L
9D5193
LATCH (L.H.)
120G, 12G, 130G, 140G, 14G, 16G, 977L
120G, 12G, 130G, 140G, 14G, 16G, 977L
6V2713
LATCH ASSEM.
977L, 983B
977L, 983B
5V5232
LATCH ASSEM.
920, D7G
920, D7G
4V8587
LATCH ASSEM.
920, D7G, D8K
920, D7G, D8K
5G1956
LATCH ASSEM.
931B, D3C II
931B, D3C II