Illustration 1 g00603288
Bus transformer box
Turn the engine control switch (ECS) to "STOP".
Locate the input wires of the BTB +.
Start the engine and run the engine at rated speed.
Close the breaker in order to energize the bus.
Measure the voltage from phase A to phase C.Expected Result:The voltage should be the normal operating voltage.Results:
OK - The voltage is the normal operating voltage. Proceed to Test Step 3.
NOT OK - The voltage is NOT the normal operating voltage.Repair: There is no voltage on phase C. Use the System Schematic for the BTB + and the AC schematic in Testing And Adjusting, "Schematics And Wiring Diagrams" section to troubleshoot the wiring and find the exact cause of the diagnostic.STOPTest Step 3. CHECK THE VOLTAGE ON THE OUTPUT OF THE BTB+.
Stop the engine. Turn the engine control switch (ECS) to "STOP".
Install cable probes on connector contacts A and B of three-terminal connector J1 on the BTB+.
Start the engine and run the engine at rated speed.
Close the breaker in order to engergize the bus.
Measure the voltage between connector contacts A and B of J1.Expected Result:The voltage should be equal to the voltage measured in Test Step 2 divided by 15 2% (14.7 to 15.3). Results:
OK - The voltage is correct. Proceed to Test Step 4.
NOT OK - The voltage is NOT correct. The BTB+ has failed.Repair: The BTB + has failed. Replace the BTB +. See Testing and Adjusting, "EMPC Electronic Control (Bus Transformer Box) - Replace".STOPTest Step 4. CHECK THE INPUT WIRES OF THE GSC+P FROM THE BTB +.
Stop the engine. Turn the engine control switch (ECS) to "STOP".
Locate the input wires on contact 17, and contact 18 of the GSC+P from the BTB +. Install cable probes on these contacts.
Start the engine and run the engine at rated speed.
Close the breaker in order to energize the bus.
Measure the voltage between GSC+P connector contact 17 and 18.Expected Result:The voltage should be equal to the voltage measured in Test Step 2 divided by 15 2% (14.7 to 15.3). Results:
OK - The voltage is correct. CID 1170 FMI 2 is still active. Repair: The GSC+ may have failed. It is unlikely that the GSC+ has failed. Exit this procedure and perform this entire procedure again. If the problem remains, replace the GSC+. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". STOP
NOT OK - The voltage is not correct. The wiring harness has failed between the BTB + and the generator.Repair: The wiring harness has failed between the BTB + and the generator. Repair the wiring harness or replace the wiring harness. Use the System Schematic for the BTB + and the AC schematic in the Testing And Adjusting, "Schematics And Wiring Diagrams" section.STOP
Parts lever Caterpillar catalog:
3859421
LEVER AS-
Caterpillar
Caterpillar
3858739
LEVER AS-
Caterpillar
Caterpillar
3858586
LEVER AS-
Caterpillar
Caterpillar
3858483
LEVER AS-
Caterpillar
Caterpillar
3858478
LEVER AS-
Caterpillar
Caterpillar
3858473
LEVER AS-
Caterpillar
Caterpillar
3866036
LEVER AS-HOIST
Caterpillar
Caterpillar
3866035
LEVER AS-HOIST
Caterpillar
Caterpillar
3866034
LEVER AS-HOIST
Caterpillar
Caterpillar
3866033
LEVER AS-HOIST
Caterpillar
Caterpillar
3866032
LEVER AS-HOIST
Caterpillar
Caterpillar
3866031
LEVER AS-HOIST
Caterpillar
Caterpillar