8D5634 LEVER Caterpillar parts
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
Rating:
Alternative (cross code) number:
CA8D5634
8D-5634
8D5634
CA8D5634
8D-5634
8D5634
Weight: 0.40 pounds 0 kg.
MOTOR GRADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 8D5634:
Information:
Check the exciter armature. Ensure that the rotating rectifier is tight. If a failure of a rectifier is suspected, proceed to the "Testing a Three-Diode Rectifier Block" section.Testing a Three-Diode Rectifier Block
Illustration 1 g00610240
Illustration 2 g00613971
Three-Diode Rectifier Block (two pieces)The following procedure tests all three diodes within a block. Check the positive rectifier block and the negative rectifier block. If any meter reading does not fall within the given ranges, replace the rectifier block.
Set the digital multimeter on the diode range. Remove all leads from the rectifier block.
To test the negative rectifier block, follow these steps:
Place the red test lead on the negative "-" terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.
Place the black test lead on the negative "-" terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
To test the positive rectifier block, follow these steps:
Place the red test lead on the positive "+" rectifier terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
Place the black test lead on the positive "+" rectifier terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.Note: A shorted diode can cause damage to the exciter rotor. If a diode is shorted, check the exciter rotor. Refer to the Testing and Adjusting, "Winding - Test" and Testing and Adjusting, "Insulation - Test". Perform these tests.Note: This rectifier block also contains varistor "CR7". "CR7" can be checked by measuring the resistance between the positive "+" rectifier terminal and the negative "-" rectifier terminal. The resistance should be a minimum of 15000.
Illustration 1 g00610240
Illustration 2 g00613971
Three-Diode Rectifier Block (two pieces)The following procedure tests all three diodes within a block. Check the positive rectifier block and the negative rectifier block. If any meter reading does not fall within the given ranges, replace the rectifier block.
Set the digital multimeter on the diode range. Remove all leads from the rectifier block.
To test the negative rectifier block, follow these steps:
Place the red test lead on the negative "-" terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.
Place the black test lead on the negative "-" terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
To test the positive rectifier block, follow these steps:
Place the red test lead on the positive "+" rectifier terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
Place the black test lead on the positive "+" rectifier terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.Note: A shorted diode can cause damage to the exciter rotor. If a diode is shorted, check the exciter rotor. Refer to the Testing and Adjusting, "Winding - Test" and Testing and Adjusting, "Insulation - Test". Perform these tests.Note: This rectifier block also contains varistor "CR7". "CR7" can be checked by measuring the resistance between the positive "+" rectifier terminal and the negative "-" rectifier terminal. The resistance should be a minimum of 15000.
Cat SIS web machinery list:
Parts lever Caterpillar catalog:
1U4661
LEVER GP
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
4M1853
LEVER AS-SHIFT
1090, 1140, 1150, 1160, 1190, 1190T, 120M, 120M 2, 1290T, 12E, 12M 2, 12M 3, 12M 3 AWD, 130G, 1390, 140G, 140M, 140M 2, 140M 3, 140M 3 AWD, 14H, 14M, 16, 160M, 160M 2, 160M 3, 160M 3 AWD, 1673, 1673B,...
1090, 1140, 1150, 1160, 1190, 1190T, 120M, 120M 2, 1290T, 12E, 12M 2, 12M 3, 12M 3 AWD, 130G, 1390, 140G, 140M, 140M 2, 140M 3, 140M 3 AWD, 14H, 14M, 16, 160M, 160M 2, 160M 3, 160M 3 AWD, 1673, 1673B,...
4N0445
LEVER-LOAD STOP
120G, 12G, 130G, 140G, 1673C, 215, 225, 231D, 235, 3160, 3208, 3304, 3306, 518, 528, 613B, 613C, 627B, 637D, 639D, 920, 941, 950, 955L, 977K, 980B, CB-614, CS-551, D4D, D4E, D5, D5B, D6C, D6D, D7F, D7...
120G, 12G, 130G, 140G, 1673C, 215, 225, 231D, 235, 3160, 3208, 3304, 3306, 518, 528, 613B, 613C, 627B, 637D, 639D, 920, 941, 950, 955L, 977K, 980B, CB-614, CS-551, D4D, D4E, D5, D5B, D6C, D6D, D7F, D7...
9M7394
LEVER
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 16, 160G, 160H, 160H ES, 160H N...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 16, 160G, 160H, 160H ES, 160H N...
1140268
LEVER AS
143H, 163H, 163H NA, 3126, 3126B, 3176B, 3176C, 3196, 3406E, 3408E, 3412E, 3456, 3508B, 3512, 3512B, 3512C, 3516B, 3516C, C-10, C-12, C-15, C-16, C-9, C11, C13, C15, C18, C27, C32, C7, C9, C9.3, CX31-...
143H, 163H, 163H NA, 3126, 3126B, 3176B, 3176C, 3196, 3406E, 3408E, 3412E, 3456, 3508B, 3512, 3512B, 3512C, 3516B, 3516C, C-10, C-12, C-15, C-16, C-9, C11, C13, C15, C18, C27, C32, C7, C9, C9.3, CX31-...
8D5996
LEVER
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA
9T4916
LEVER
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8D5633
LEVER
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
8D5632
LEVER
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
8D5635
LEVER
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
5T6298
LEVER
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8J1616
LEVER
120G, 130G, 140G, 16G
120G, 130G, 140G, 16G
9T4916
LEVER
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
9D0945
LEVER AS
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
3P3426
LEVER
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA
3P6159
LEVER
120G, 12G, 130G, 140G, 160G
120G, 12G, 130G, 140G, 160G
8W0317
LEVER
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8D5996
LEVER
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA
5T6298
LEVER
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8W2666
LEVER
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8D5631
LEVER
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8D5635
LEVER
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8D5632
LEVER
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
8D5633
LEVER
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...