Information:
Starting the Engine
1. Perform all before-starting inspections. Refer to "Before Starting" in the Engine Operation and Maintenance Guide. 2. Turn Engine Control Switch (1) to the engine Start position. The switch should be held in the start position, if equipped with a Manual Start-Stop Module, until oil pressure is sufficient to deactivate (de-arm) the oil pressure failure circuit. Even though the switch is held in this position, crank termination will occur automatically when the speed switch senses crank termination speed.3. When engine starts, the engine fault circuits are now functional (armed). Should a fault occur, the engine will be automatically shut down. To restart the engine after being shutdown by a fault, first correct the fault condition, then turn switch (1) to the Off-Reset position. Next start the engine as per step 2.4. After the engine starts and its systems have stabilized, apply the load.5. Regulate the frequency of the generator with the Governor Motor Control Switch (2) or Manual Governor Control Lever.Stopping the Engine
1. Remove the load from the engine.2. If it is desired to run the engine at high idle (rated speed) for cool down at no load, turn the Engine Control Switch (ECS) to the Stop position, this will allow the engine to run for the preset, or programmed cool down time before shutdown. If high idle cool down at no load is not desired proceed to Step 3.3. Reduce engine speed to Low idle (approximately 2/3 the full load speed of 60 Hz units or 4/5 full load speed of 50 Hz units). Push down on the Governor Control Switch until low idle is achieved (for electric governors), or move the Manual Governor Control lever to the low idle position (for mechanical governors).4. While the engine is at low idle, measure the engine oil level. Oil level must be maintained between the Add and Full marks on the Engine Running side of the dipstick. For 3100 and 3200 Series engines, the oil level cannot be measured with the engine running.5. Allow the engine to cool down while running at low idle (approximately five minutes). After engine cools, turn the Engine Control Switch to the Off-Reset position.Emergency Stopping
The Emergency Stop Button is red in color and is used to shutdown the engine only in an emergency situation.Reset and Check Emergency Stop Switches
If the emergency stop switch was used to shut down the engine, it will be necessary to reset the switch. To reset the switch, pull out and rotate the button in the direction shown. Before starting, check the emergency stop buttons located on the engine junction box (if equipped) and control panel. If the emergency stop button was used to shutdown the engine it will be necessary to reset the air shutoff (if equipped).Before starting the engine, correct the problem that necessitated the emergency stop.
1. Perform all before-starting inspections. Refer to "Before Starting" in the Engine Operation and Maintenance Guide. 2. Turn Engine Control Switch (1) to the engine Start position. The switch should be held in the start position, if equipped with a Manual Start-Stop Module, until oil pressure is sufficient to deactivate (de-arm) the oil pressure failure circuit. Even though the switch is held in this position, crank termination will occur automatically when the speed switch senses crank termination speed.3. When engine starts, the engine fault circuits are now functional (armed). Should a fault occur, the engine will be automatically shut down. To restart the engine after being shutdown by a fault, first correct the fault condition, then turn switch (1) to the Off-Reset position. Next start the engine as per step 2.4. After the engine starts and its systems have stabilized, apply the load.5. Regulate the frequency of the generator with the Governor Motor Control Switch (2) or Manual Governor Control Lever.Stopping the Engine
1. Remove the load from the engine.2. If it is desired to run the engine at high idle (rated speed) for cool down at no load, turn the Engine Control Switch (ECS) to the Stop position, this will allow the engine to run for the preset, or programmed cool down time before shutdown. If high idle cool down at no load is not desired proceed to Step 3.3. Reduce engine speed to Low idle (approximately 2/3 the full load speed of 60 Hz units or 4/5 full load speed of 50 Hz units). Push down on the Governor Control Switch until low idle is achieved (for electric governors), or move the Manual Governor Control lever to the low idle position (for mechanical governors).4. While the engine is at low idle, measure the engine oil level. Oil level must be maintained between the Add and Full marks on the Engine Running side of the dipstick. For 3100 and 3200 Series engines, the oil level cannot be measured with the engine running.5. Allow the engine to cool down while running at low idle (approximately five minutes). After engine cools, turn the Engine Control Switch to the Off-Reset position.Emergency Stopping
The Emergency Stop Button is red in color and is used to shutdown the engine only in an emergency situation.Reset and Check Emergency Stop Switches
If the emergency stop switch was used to shut down the engine, it will be necessary to reset the switch. To reset the switch, pull out and rotate the button in the direction shown. Before starting, check the emergency stop buttons located on the engine junction box (if equipped) and control panel. If the emergency stop button was used to shutdown the engine it will be necessary to reset the air shutoff (if equipped).Before starting the engine, correct the problem that necessitated the emergency stop.
Parts lighting Caterpillar catalog:
4359589
LIGHTING GP
Caterpillar
Caterpillar
4359568
LIGHTING GP
Caterpillar
Caterpillar
4359567
LIGHTING GP
Caterpillar
Caterpillar
4353422
LIGHTING GP
Caterpillar
Caterpillar
4348340
LIGHTING AR
Caterpillar
Caterpillar
4347660
LIGHTING GP-
Caterpillar
Caterpillar
4360864
LIGHTING GP
Caterpillar
Caterpillar
4364674
LIGHTING GP-
Caterpillar
Caterpillar
4383368
LIGHTING GP-
Caterpillar
Caterpillar
4387671
LIGHTING GP
Caterpillar
Caterpillar
4395503
LIGHTING AR
Caterpillar
Caterpillar
4395511
LIGHTING AR
Caterpillar
Caterpillar