0651591 LINE A Caterpillar parts
Rating:
Alternative (cross code) number:
CA0651591
065-1591
0651591
CA0651591
065-1591
0651591
Weight: 2 pounds 1 kg.
Information:
Illustration 1 g01620487
Schematic of the "Body Lower/Ejector Return" solenoid
This diagnostic code is associated with the "Body Lower/Ejector Return" solenoid. This diagnostic code is recorded when the ECM reads the voltage of the solenoid valve circuit as being above normal. The circuit is shorted to the +battery circuit.The possible causes of this failure are listed below:
The energized circuit for the solenoid valve is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: Ensure that the diagnostic code is active.Test Step 1. CHECK THE SOLENOID CIRCUIT FOR A SHORT TO THE + BATTERY.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the solenoid valve.
Disconnect the machine harness connectors J1 and J2 from the ECM.
At machine harness connector J1 and J2, measure the resistance from the signal contact J1-68 (wire G704-YL(Yellow)) to all possible sources of positive voltage. Expected Result:Each resistance should be greater than 5 ohms.Results:
YES - Each resistance is greater than 5 ohms. The machine harness is correct. Proceed to test step 2.
NO - There is a short in the machine harness. Repair: The short is between the signal contact J1-68 (wire G704-YL(Yellow)) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Clear all inactive diagnostic codes.
Operate the machine.
Stop the machine.
Check if the diagnostic code for the solenoid valve is present. Expected Result:The diagnostic code for the solenoid valve is NO longer present.Results:
YES - The diagnostic code is NOT present. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
NO - The diagnostic code has not been corrected.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Also, recheck if the diagnostic code is active. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
Parts line Caterpillar catalog:
0651590
LINE A
Caterpillar
Caterpillar
0650742
LINE A.
Caterpillar
Caterpillar
0650146
LINE A
Caterpillar
Caterpillar
0649800
LINE A
Caterpillar
Caterpillar
0649799
LINE A
Caterpillar
Caterpillar
0643434
LINE
Caterpillar
Caterpillar
0669493
LINE A.
Caterpillar
Caterpillar
0669491
LINE A.
Caterpillar
Caterpillar
0669217
LINE A.
Caterpillar
Caterpillar
0658553
LINE A.
Caterpillar
Caterpillar
0657518
LINE A
Caterpillar
Caterpillar
0657509
LINE ASSY
Caterpillar
Caterpillar