6N5135 LINE ASSEM. (no. 5) Caterpillar parts
245, 3406, 621, 980C
Rating:
Alternative (cross code) number:
CA6N5135
6N-5135
6N5135
CA6N5135
6N-5135
6N5135
Weight: 0.40 pounds 0 kg.
EXCAVATOR, WHEEL TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 6N5135:
Information:
System Operation Description:The event code, 4012-31 for utility breaker failure to close will become active when the following occurs:
The utility breaker does not change state after the EMCP has requested to close the utility breaker.The EMCP has activated the relay or digital output designated for the utility breaker. The utility breaker position is not being detected as closed at the digital inputs for Utility Breaker AUX A.
View active and logged diagnostic codes to determine if there are any other diagnostics that may indicate a problem with the system which may lead to a transfer failure.
Verify EMCP set point for "Utility Breaker Maximum Close Time" event timer limits. Ensure that the timer is set to the appropriate time allotted to complete system transfer.
Wiring: Inspect system wiring for intermittent open circuits and high resistance, loose connections, and shorts to ground in between the EMCP relay or digital output. EMCP relay or digital output is designated for Utility breaker control to the Utility breaker.Test Step 1. Check the Wiring Harness for an Open Circuit or a Short Circuit to Ground
Disconnect battery power from the engine.
Disconnect the wiring harness from the EMCP and utility breaker.
Measure the resistance of the wiring between the designated relay or digital output and the utility breaker or utility breaker control device. If more than 10 ohms of resistance is found, there should be an open circuit or bad connection. Repair or replace the wiring. If less than 10 ohms of resistance is found, measure for battery voltage at the EMCP relay or digital output pin, and utility breaker connection point. If battery power is found at both points, there may be a problem with the utility breaker. If battery power is not present at the utility breaker but present at the EMCP, repair or replace the wiring in between the EMCP and breaker connections.Results:
- STOP
The utility breaker does not change state after the EMCP has requested to close the utility breaker.The EMCP has activated the relay or digital output designated for the utility breaker. The utility breaker position is not being detected as closed at the digital inputs for Utility Breaker AUX A.
View active and logged diagnostic codes to determine if there are any other diagnostics that may indicate a problem with the system which may lead to a transfer failure.
Verify EMCP set point for "Utility Breaker Maximum Close Time" event timer limits. Ensure that the timer is set to the appropriate time allotted to complete system transfer.
Wiring: Inspect system wiring for intermittent open circuits and high resistance, loose connections, and shorts to ground in between the EMCP relay or digital output. EMCP relay or digital output is designated for Utility breaker control to the Utility breaker.Test Step 1. Check the Wiring Harness for an Open Circuit or a Short Circuit to Ground
Disconnect battery power from the engine.
Disconnect the wiring harness from the EMCP and utility breaker.
Measure the resistance of the wiring between the designated relay or digital output and the utility breaker or utility breaker control device. If more than 10 ohms of resistance is found, there should be an open circuit or bad connection. Repair or replace the wiring. If less than 10 ohms of resistance is found, measure for battery voltage at the EMCP relay or digital output pin, and utility breaker connection point. If battery power is found at both points, there may be a problem with the utility breaker. If battery power is not present at the utility breaker but present at the EMCP, repair or replace the wiring in between the EMCP and breaker connections.Results:
- STOP
Cat SIS web machinery list:
Parts line Caterpillar catalog:
7C3427
LINE AS-FUEL INJECTION
16G, 245, 3406B, 3406C, 375, 375 L, 5080, 578, 621E, 621F, 623E, 627E, 627F, 826C, 980C, 980F, 980G, D8N, RR-250, SS-250
16G, 245, 3406B, 3406C, 375, 375 L, 5080, 578, 621E, 621F, 623E, 627E, 627F, 826C, 980C, 980F, 980G, D8N, RR-250, SS-250
7N8371
LINE AS-FUEL INJ
245, 3406, 980C
245, 3406, 980C
4N9971
LINE AS-FUEL INJ
245, 3406
245, 3406
4N9972
LINE AS-FUEL INJ
245, 3406
245, 3406
4N9973
LINE AS-FUEL INJ
245, 3406
245, 3406
4N9974
LINE AS-FUEL INJ
245, 3406
245, 3406
4N9975
LINE AS-FUEL INJ
245, 3406
245, 3406
4N9976
LINE AS-FUEL INJ
245, 3406
245, 3406
6N5131
LINE ASSEM. (no. 1)
245, 3406, 621, 980C
245, 3406, 621, 980C
6N5136
LINE ASSEM. (no. 6)
245, 3406, 621, 980C
245, 3406, 621, 980C
1W4660
LINE ASSEM.
980C
980C
6N5134
LINE ASSEM. (no. 4)
245, 3406, 621, 980C
245, 3406, 621, 980C
6N5133
LINE ASSEM. (no. 3)
245, 3406, 621, 980C
245, 3406, 621, 980C
6N5132
LINE ASSEM. (no. 2)
245, 3406, 621, 980C
245, 3406, 621, 980C
6N5131
LINE ASSEM. (no. 1)
245, 3406, 621, 980C
245, 3406, 621, 980C
4N9976
LINE AS-FUEL INJ
245, 3406
245, 3406
4N9975
LINE AS-FUEL INJ
245, 3406
245, 3406
5N4207
LINE ASSEM. (no. 7)
D379B, D398B
D379B, D398B
6N5136
LINE ASSEM. (no. 6)
245, 3406, 621, 980C
245, 3406, 621, 980C