1735562 LINES GP-WATER Caterpillar parts
D9R
Rating:
Alternative (cross code) number:
CA1735562
173-5562
1735562
CA1735562
173-5562
1735562
TRACK-TYPE TRACTOR,
Compatible equipment models: 1735562:
Caterpillar SIS machinery equipment:
Caterpillar SIS
D9R Track-Type Tractor Differential Steering ABK00001-UP (MACHINE) POWERED BY 3408 Engine »
173-5562
LINES GP-WATER
D9R Track-Type Tractor Differential Steering ABK00001-UP (MACHINE) POWERED BY 3408 Engine »
173-5562
LINES GP-WATER
D9R Track-Type Tractor Power Shift ACL00001-UP (MACHINE) POWERED BY 3408 Engine »
173-5562
LINES GP-WATER
D9R Track-Type Tractor Power Shift ACL00001-UP (MACHINE) POWERED BY 3408 Engine »
173-5562
LINES GP-WATER
D9R TRACK-TYPE TRACTOR WDM00001-UP (MACHINE) POWERED BY 3408C Engine »
173-5562
LINES GP-WATER
D9R TRACK-TYPE TRACTOR WDM00001-UP (MACHINE) POWERED BY 3408C Engine »
173-5562
LINES GP-WATER
Caterpillar parts catalog:
Information:
of maximum speed, the actual gain will be 25 percent of the set point value and Stability and Compensation values will be two times greater than at maximum speed.The Constant Map provides a Gain which is constant at all engine speeds for some medium- to high-speed engines. Stability and Compensation are also held constant.The final decision on which map to use depends on engine performance obtained throughout the operating speed and load range. After tuning the control for desired performance under rated speed and load conditions, performance at low speed and light loads should be evaluated. If low frequency speed oscillation occurs at low speeds using the Linear Map, the Nonlinear Map will provide additional Stability. If performance is poor at low speed using the Nonlinear Map, the Linear and Constant Maps will provide higher performance. Select the map that provides the best overall performance for all operating conditions.7. MPU1 Failed Alarm sets the alarm condition which will occur when a loss of the speed sensor #1 input signal has been detected. Alarm selection may be Major Alarm, Minor Alarm, or None.8. MPU2 Failed Alarm sets the alarm condition which will occur when a loss of the speed sensor #2 input signal has been detected. Alarm selection may be Major Alarm, Minor Alarm, or None.9. Both MPUs Failed Alarm sets the alarm condition which will occur when a loss of the speed sensor #1 and #2 input signals has been detected. Alarm selection may be Major Alarm, Minor Alarm, or None.10. Load Sensor Failed Alarm sets the alarm condition which will occur when the KW Transducer input drops below 2 mA. Alarm selection may be Major Alarm, Minor Alarm, or None.11. Sequence Error Alarm sets the alarm condition which will occur when a sequence error has been detected. Alarm selection may be Major Alarm, Minor Alarm, or None.12. High Torsional Level Alarm sets the alarm condition which will occur when the torsional Derated Trip Level set point (Menu 4) has been exceeded. Alarm selection may be Major Alarm, Minor Alarm, or None.13. Remote Input Failed Alarm sets the alarm condition which will occur when the Remote Speed/Load Setting input drops below 2 mA. Alarm selection may be Major Alarm, Minor Alarm, or None.Menu 9 - Calibration Menu
Input and output values are displayed once when each item is selected. Woodward Governor Company has done a factory calibration on the control prior to shipment, and it should not normally require field adjustment. See the Control Test and Calibration section in Chapter 7 for proper adjustment procedure.1. Calibration Key is a code which you must enter before you can change any of the set points on the calibration menu. This helps prevent accidental modification of the set points. The code is factory set to "49". Use the "Turtle Up" and "Turtle Down" keys to select the code. Whenever the Minimum Fuel (Run/Stop) input is changed, the code will be reset to "0". The Minimum Fuel (Run/Stop) contact must be open,
Input and output values are displayed once when each item is selected. Woodward Governor Company has done a factory calibration on the control prior to shipment, and it should not normally require field adjustment. See the Control Test and Calibration section in Chapter 7 for proper adjustment procedure.1. Calibration Key is a code which you must enter before you can change any of the set points on the calibration menu. This helps prevent accidental modification of the set points. The code is factory set to "49". Use the "Turtle Up" and "Turtle Down" keys to select the code. Whenever the Minimum Fuel (Run/Stop) input is changed, the code will be reset to "0". The Minimum Fuel (Run/Stop) contact must be open,
Parts lines Caterpillar catalog:
1308909
LINES GP-FUEL FILTER
D8L, D9N, D9R
D8L, D9N, D9R
1307310
LINES GP-WATER
D8L, D9N, D9R
D8L, D9N, D9R
1308907
LINES GP-TURBOCHARGER OIL
D8L, D9N, D9R
D8L, D9N, D9R
1393210
LINES GP-WATER
D8L, D9N, D9R
D8L, D9N, D9R
1356410
LINES GP-RIPPER
D9R, D9T
D9R, D9T
6I0030
LINES GP-FUEL INJECTION
3408, 3408C, 3412C, 589, 631E, 637E, 657E, 768C, 769C, 771C, 834B, 988B, 988F, D8L, D9N, D9R, PM-565, PR-450, PR-450C
3408, 3408C, 3412C, 589, 631E, 637E, 657E, 768C, 769C, 771C, 834B, 988B, 988F, D8L, D9N, D9R, PM-565, PR-450, PR-450C
8N2304
LINES GP-AFTERCOOLER WATER
3408, 589, 631E, 637E, 657E, 988F, D8L, D9R
3408, 589, 631E, 637E, 657E, 988F, D8L, D9R
3313675
LINES GP-FUEL INJECTION
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F, C175-16, C175-20
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F, C175-16, C175-20
2741744
LINES GP-COOLANT
3512C, 3516C
3512C, 3516C
9Y6577
LINES GP-FUEL INJECTION
3126, 3516, 3516B, PM3516
3126, 3516, 3516B, PM3516
2506181
LINES GP-RIPPER
120M, 12M, 140M, 160M
120M, 12M, 140M, 160M
1738042
LINES GP-AUXILIARY HYDRAULIC
307C, 308C
307C, 308C
3777634
LINES GP-PUMP
906H2, 907H2, 908H2
906H2, 907H2, 908H2
2027022
LINES GP-BOOM
385B, 385C, 385C L, 5090B
385B, 385C, 385C L, 5090B
5T2381
LINES GP-HOIST
769C, 769D, 771C, 771D
769C, 769D, 771C, 771D
1541695
LINES GP-INSTRUMENT PANEL
3612, 3616, C280-12, C280-16
3612, 3616, C280-12, C280-16
2555146
LINES GP-PILOT
385C, 385C L, 385C L MH
385C, 385C L, 385C L MH