Information:
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
Early hour failure of the 356-5379 Alarm Module Gp. The failure mode is typically the module has no lights, unable to communicate, does not work, and internal defect open-shorted. Alarm panel inoperable, found green light flashing at bottom and RS485 annunciator circuit failed.Solution
Removed the original 356-5379 Alarm Module Gp and replaced with a new 356-5379 Alarm Module Gp.Reference: Application & Installation Guide, LEBE0006, EMCP 4.1, 4.2 GENERATOR SET CONTROLReference: Application & Installation Guide, LEBE0007, Cat® EMCP 4.3 and 4.4 Generator Set Control.RS-485 Annunciator
The RS-485 Annunciator uses a custom master-slave communication protocol. The EMCP 4 controller will be the Master, and the RS-485 Annunciator(s) will be the slave(s). Configuration takes place within the EMCP 4. In Local application, the RS-485 Annunciator may be mounted on the Package generator set with the EMCP 4 to provide a complete package-mounted monitoring solution. The RS-485 Annunciator may also be mounted separately from the generator set to provide Remote indication of system operating and alarm conditions. The number of RS-485 Annunciators is limited by the RS-485 standard.Network Communications Interface
EMCP 4 provides a dedicated, fully isolated RS-485 SCADA Data Link (Half Duplex) separate from the MODBUS port used on the EMCP 4
Operates at 19200 bits per second
Configuration is accomplished with the Cat Service Tool by connecting to the EMCP 4
RS-485 Annunciator communication is not compatible with third-party devices.Annunciator Electrical Specifications
Control Power 12 VDC and 24 VDC nominal (9 VDC through 32 VDC acceptable)
Reverse voltage capability is -32 VDC for 1 hour at 70° C (158° F)
Over voltage capability is 80 VDC for 2 minutes at 70° C (158° F)
Single, 8-pin connector provides both power and communication
Designed to meet relevant European standards for EMI/RFI/Immunity without the use of external filteringRS-485 ANNUNCIATOR CUSTOM ALARM GROUP CONFIGURATION
The RS-485 Annunciator LED is field-programmable by the EMCP 4 via the Cat Service Tool when configured for Alarm Group’s 01 and 02. Alarm Group’s 01 and 02 support customization of the 32 events for the 16 LED’s.The service tool software must be installed on a Windows PC.The Cat communication adapter must be connected between the PC and the CAN Primary data link on which the target EMCP 4 is connected.RS-485 ANNUNCIATOR ALARM GROUPS
The RS-485 Annunciator supports four different Alarm Groups. Alarm Group 01, 02, 03, and Alarm Group 04. Two of these Alarm Groups, 03 and 04, are fixed and are not configurable and two Alarm Groups, 01 and 02, are reserved for custom event settings and are fully configurable. Selecting which of the four Alarm Groups to configure the RS-485 Annunciator is determined by the film that is placed on the front left panel. The Alarm Groups and the events that make up the films for each of the Alarm Groups are detailed below in Tables 24, 25, and 26. Configuring the RS-485 Annunciator to one of the four Alarm Groups is accomplished through
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
Early hour failure of the 356-5379 Alarm Module Gp. The failure mode is typically the module has no lights, unable to communicate, does not work, and internal defect open-shorted. Alarm panel inoperable, found green light flashing at bottom and RS485 annunciator circuit failed.Solution
Removed the original 356-5379 Alarm Module Gp and replaced with a new 356-5379 Alarm Module Gp.Reference: Application & Installation Guide, LEBE0006, EMCP 4.1, 4.2 GENERATOR SET CONTROLReference: Application & Installation Guide, LEBE0007, Cat® EMCP 4.3 and 4.4 Generator Set Control.RS-485 Annunciator
The RS-485 Annunciator uses a custom master-slave communication protocol. The EMCP 4 controller will be the Master, and the RS-485 Annunciator(s) will be the slave(s). Configuration takes place within the EMCP 4. In Local application, the RS-485 Annunciator may be mounted on the Package generator set with the EMCP 4 to provide a complete package-mounted monitoring solution. The RS-485 Annunciator may also be mounted separately from the generator set to provide Remote indication of system operating and alarm conditions. The number of RS-485 Annunciators is limited by the RS-485 standard.Network Communications Interface
EMCP 4 provides a dedicated, fully isolated RS-485 SCADA Data Link (Half Duplex) separate from the MODBUS port used on the EMCP 4
Operates at 19200 bits per second
Configuration is accomplished with the Cat Service Tool by connecting to the EMCP 4
RS-485 Annunciator communication is not compatible with third-party devices.Annunciator Electrical Specifications
Control Power 12 VDC and 24 VDC nominal (9 VDC through 32 VDC acceptable)
Reverse voltage capability is -32 VDC for 1 hour at 70° C (158° F)
Over voltage capability is 80 VDC for 2 minutes at 70° C (158° F)
Single, 8-pin connector provides both power and communication
Designed to meet relevant European standards for EMI/RFI/Immunity without the use of external filteringRS-485 ANNUNCIATOR CUSTOM ALARM GROUP CONFIGURATION
The RS-485 Annunciator LED is field-programmable by the EMCP 4 via the Cat Service Tool when configured for Alarm Group’s 01 and 02. Alarm Group’s 01 and 02 support customization of the 32 events for the 16 LED’s.The service tool software must be installed on a Windows PC.The Cat communication adapter must be connected between the PC and the CAN Primary data link on which the target EMCP 4 is connected.RS-485 ANNUNCIATOR ALARM GROUPS
The RS-485 Annunciator supports four different Alarm Groups. Alarm Group 01, 02, 03, and Alarm Group 04. Two of these Alarm Groups, 03 and 04, are fixed and are not configurable and two Alarm Groups, 01 and 02, are reserved for custom event settings and are fully configurable. Selecting which of the four Alarm Groups to configure the RS-485 Annunciator is determined by the film that is placed on the front left panel. The Alarm Groups and the events that make up the films for each of the Alarm Groups are detailed below in Tables 24, 25, and 26. Configuring the RS-485 Annunciator to one of the four Alarm Groups is accomplished through
Caterpillar SIS machinery equipment:
Caterpillar SIS
320D RR & 320D LRR Excavators EBY00001-UP (MACHINE) POWERED BY 3066 Engine »
266-8023
LINES GP-BOOM CYLINDER
320D & 320D L Excavators CXY00001-UP (MACHINE) POWERED BY 3066 Engine »
266-8023
LINES GP-BOOM CYLINDER
320D & 320D L Excavators FAL00001-UP (MACHINE) POWERED BY C6.4 Engine »
266-8023
LINES GP-BOOM CYLINDER
320D LN Excavator WBN00001-UP (MACHINE) POWERED BY C6.4 Engine »
266-8023
LINES GP-BOOM CYLINDER
323D L Excavator YSD00001-UP (MACHINE) POWERED BY C6.4 Engine »
266-8023
LINES GP-BOOM CYLINDER
320D L & 320D LN Excavators GDP00001-UP (MACHINE) POWERED BY C6.4 Engine »
266-8023
LINES GP-BOOM CYLINDER
323D2 L Excavators KCE00001-UP (MACHINE) POWERED BY C7.1 Engine »
266-8023
LINES GP-BOOM CYLINDER
320D2 & 320D2 L Excavators KHR00001-UP (MACHINE) POWERED BY C7.1 Engine »
266-8023
LINES GP-BOOM CYLINDER
320D2 & 320D2 L Excavators YEA00001-UP (MACHINE) POWERED BY C7.1 Engine »
266-8023
LINES GP-BOOM CYLINDER
320D2 & 320D2 L Excavators KBS00001-UP (MACHINE) POWERED BY C7.1 Engine »
266-8023
LINES GP-BOOM CYLINDER
320D2 & 320D2 L Excavators LCA00001-UP (MACHINE) POWERED BY C7.1 Engine »
266-8023
LINES GP-BOOM CYLINDER
320D2 & 320D2 L Excavator DNS00001-UP (MACHINE) POWERED BY C7.1 Engine »
266-8023
LINES GP-BOOM CYLINDER
Caterpillar parts catalog:
Parts lines Caterpillar catalog:
4252178
LINES GP-FUEL
323D2 L, 535D, 545D, 924K, 930K, 938K, 950 GC, C7.1, D6K2
323D2 L, 535D, 545D, 924K, 930K, 938K, 950 GC, C7.1, D6K2
3940525
LINES GP-FUEL INJECTION
323D2 L, 535D, 545D, 924K, 930K, 938K, 950 GC, C7.1, D6K2
323D2 L, 535D, 545D, 924K, 930K, 938K, 950 GC, C7.1, D6K2
3963549
LINES GP-COOLING
323D2 L
323D2 L
3687668
LINES GP-FUEL
323D2 L
323D2 L
4411213
LINES GP-FUEL FILTER
323D2 L
323D2 L
3766325
LINES GP-FRONT
320D2 L, 323D2 L
320D2 L, 323D2 L
3766329
LINES GP-FRONT
323D2 L
323D2 L
3766332
LINES GP-FRONT
320D2, 320D2 L, 323D2 L
320D2, 320D2 L, 323D2 L
3766327
LINES GP-PILOT
320D2, 323D2 L
320D2, 323D2 L
3984604
LINES GP-PILOT
323D2 L
323D2 L
4243293
LINES GP-PILOT
323D2 L
323D2 L
3766340
LINES GP-PILOT
320D2 L
320D2 L
6G2270
LINES GP-STEERING
631D, 637D
631D, 637D
3714797
LINES GP-HYDRAULIC OIL COOLER
773G, 773G LRC, 773G OEM, 775G, 775G LRC, 775G OEM
773G, 773G LRC, 773G OEM, 775G, 775G LRC, 775G OEM
3984603
LINES GP-PILOT
323D2 L
323D2 L
8W5043
LINES GP-STEERING
631E, 637E
631E, 637E
3359162
LINES GP-AIR
416E, 422E, 428E, 432E, 434E, 442E, 444E
416E, 422E, 428E, 432E, 434E, 442E, 444E
3090781
LINES GP-HYDRAULIC
120M, 120M 2, 12M
120M, 120M 2, 12M
2152445
LINES GP-STABILIZER
420E, 430E
420E, 430E
2825627
LINES GP-AUXILIARY HYDRAULIC
311D LRR, 311F LRR
311D LRR, 311F LRR