Removal Procedure
Start By:
Remove the heater coil. Refer to Disassembly and Assembly, "Heater Coil - Remove and Install".
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification marks on all lines and on all tubes for installation purposes. Plug all lines and all tubes. This will help to prevent fluid loss and this will help to keep contaminants from entering the system.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g01067371
Disconnect tube assemblies (2) and (3) .
Remove evaporator coil (1) .Installation Procedure
Illustration 2 g01067371
Position evaporator coil (1) .
Connect hose assemblies (2) and (3) .
Evacuate the air conditioner system. Charge the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.End By: Install the heater coil. Refer to Disassembly and Assembly, "Heater Coil - Remove and Install".
Start By:
Remove the heater coil. Refer to Disassembly and Assembly, "Heater Coil - Remove and Install".
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification marks on all lines and on all tubes for installation purposes. Plug all lines and all tubes. This will help to prevent fluid loss and this will help to keep contaminants from entering the system.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g01067371
Disconnect tube assemblies (2) and (3) .
Remove evaporator coil (1) .Installation Procedure
Illustration 2 g01067371
Position evaporator coil (1) .
Connect hose assemblies (2) and (3) .
Evacuate the air conditioner system. Charge the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.End By: Install the heater coil. Refer to Disassembly and Assembly, "Heater Coil - Remove and Install".
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts lines Caterpillar catalog:
2426757
LINES GP-BUCKET CYLINDER
320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321D LCR, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D, 324D L
320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321D LCR, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D, 324D L
2426488
LINES GP-AUXILIARY HYDRAULIC
320D, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 L, 321D LCR, 323D L, 323D LN, 323D SA, 323D2 L, 323E L
320D, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 L, 321D LCR, 323D L, 323D LN, 323D SA, 323D2 L, 323E L
2254592
LINES GP-BUCKET CYLINDER
320D, 320D FM, 320D L, 320D2, 320D2 L, 320E LN, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 325D, 325D L, 328D LCR, 329D, 329D L, 329E, 329E L, 329E LN
320D, 320D FM, 320D L, 320D2, 320D2 L, 320E LN, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 325D, 325D L, 328D LCR, 329D, 329D L, 329E, 329E L, 329E LN
2687257
LINES GP-STICK CYLINDER
320D, 320D L, 320E, 320E L, 320E LN
320D, 320D L, 320E, 320E L, 320E LN
2391699
LINES GP-BOOM CYLINDER
320D, 320D FM, 320D GC, 320D L, 320D2, 320D2 GC, 320D2 L, 323D L, 323D LN, 323D2 L
320D, 320D FM, 320D GC, 320D L, 320D2, 320D2 GC, 320D2 L, 323D L, 323D LN, 323D2 L
2608007
LINES GP-FRONT
320D, 320D L, 323D L
320D, 320D L, 323D L
2668024
LINES GP-STICK CYLINDER
320D, 320D L, 320D LN, 320D LRR, 320D2, 320D2 L, 323D L, 323D2 L
320D, 320D L, 320D LN, 320D LRR, 320D2, 320D2 L, 323D L, 323D2 L
4311642
LINES GP-STICK
320D, 320D L, 320D LRR, 320D RR, 320D2, 320D2 L, 321D LCR, 323D L, 323D2 L
320D, 320D L, 320D LRR, 320D RR, 320D2, 320D2 L, 321D LCR, 323D L, 323D2 L
2724744
LINES GP-AIR
320D, 320D FM, 320D GC, 320D L, 323D L, 323D LN
320D, 320D FM, 320D GC, 320D L, 323D L, 323D LN
2489633
LINES GP-STICK
320D, 320D L, 320D2, 320D2 L, 323D L, 323D LN, 323D2 L
320D, 320D L, 320D2, 320D2 L, 323D L, 323D LN, 323D2 L
2607983
LINES GP-PUMP
320D, 320D FM, 320D L, 323D L, 323D LN
320D, 320D FM, 320D L, 323D L, 323D LN
2895390
LINES GP-FRONT
320D L, 320D LN
320D L, 320D LN
2380797
LINES GP-PILOT
320C, 320D L
320C, 320D L
3254052
LINES GP-FRONT
320D L
320D L
3230673
LINES GP-PILOT
320D L
320D L
3230756
LINES GP-PILOT
320D L
320D L
3274737
LINES GP-PILOT
321D LCR
321D LCR
2380798
LINES GP-GREASE
320C, 320D L
320C, 320D L
2380796
LINES GP-BOOM
320C, 320D L
320C, 320D L
2504835
LINES GP-BOOM
320C, 320D L
320C, 320D L
3254115
LINES GP-BOOM
320D L
320D L
3254246
LINES GP-PILOT
320D L
320D L
3254114
LINES GP-PILOT
320D L
320D L