3307458 LINES GP-WATER Caterpillar parts
G3516, G3516B
Rating:
Alternative (cross code) number:
CA3307458
330-7458
3307458
CA3307458
330-7458
3307458
GAS ENGINE,
This part in 2 request:
Show.
This information for suppliers only!
2021-05-14
2021-04-26
Information:
Illustration 1 g01961633
Schematic for the backup alarm for the 432E, 434E, 442E, and 444ENote: This procedure applies to the following models:
432E
434E
442E
444EThe ECM applies power to the backup alarm whenever the ECM receives a signal from the reverse direction switch.The possible causes for the backup alarm are listed:
The backup alarm has failed.
The harness circuit is open.
The harness circuit is shorted to ground.
The ECM has failed.Note: Ensure that there are no active diagnostic codes for the direction switch.Test Step 1. CHECK THE BACKUP ALARM
Disconnect the backup alarm from the harness.
Use jumpers to connect the respective terminals of the backup alarm to a + battery and ground.Expected Result:The backup alarm sounds when power is applied.Results:
YES - The backup sounds when power is applied. Proceed to Test Step 2.
NO - The backup alarm does NOT sound. The backup alarm has failed.Repair: Replace the backup alarm.STOPTest Step 2. CHECK FOR A SHORTED HARNESSThe backup alarm remains disconnected.
Turn the disconnect switch to the OFF position.
Disconnect the ECM from the harness.
At the harness connector for the ECM, measure the resistance between contact J2-13 (wire 331-OR) and all possible sources of ground.Expected Result:Each resistance should be greater than 5000 ohms.Results:
YES - The resistance is greater than 5000 Ohms (no continuity). The resistance of the harness circuit is correct. Proceed to Test Step 3.
NO - The resistance is less than 5000 Ohms (continuity). The harness has failed. Wire (331-OR) is shorted to ground in the harness.Repair: Repair the harness or replace the harness.STOPTest Step 3. CHECK FOR AN OPEN IN THE HARNESSThe backup alarm and the ECM remain disconnected from the harness.
The disconnect switch remains OFF.
At the harness connector for the ECM, place a jumper from contact J2-13 (wire 331-BR) to ground.
At the harness for the backup alarm, measure the resistance between wire (331-OR) and ground.Expected Result:There should be continuity.Results:
YES - The resistance is less than 5000 Ohms (continuity). The harness circuit resistance is correct. It is unlikely that the ECM has failed. Perform these Steps again.Repair: If the cause is not found, replace the ECM. See Troubleshooting, "Electronic Control Module (ECM) - Replace".STOP
NO - The resistance is greater than 5000 Ohms (no continuity). The harness circuit has failed. Wire (331-OR) is open in the harness between the ECM and the backup alarm relay.Repair: Repair the harness or replace the harness.STOP
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts lines Caterpillar catalog:
3914583
LINES GP-WATER
G3516B
G3516B
3824869
LINES GP-WATER
G3516B
G3516B
3824504
LINES GP-WATER
3516B, 3516C, G3516, G3516B
3516B, 3516C, G3516, G3516B
3817042
LINES GP-ENGINE OIL
3512, 3512B, 3512C, G3516, G3516B
3512, 3512B, 3512C, G3516, G3516B
3827825
LINES GP-AFTERCOOLER WATER
3512B, 3516, 3516B, 3516C, G3516
3512B, 3516, 3516B, 3516C, G3516
3834046
LINES GP-WATER
G3516, G3516B
G3516, G3516B
4153340
LINES GP-OIL SUPPLY
3512, 3512B, 3516, 3516B, G3516
3512, 3512B, 3516, 3516B, G3516
2840626
LINES GP-WATER
G3516
G3516
2834402
LINES GP-WATER
G3516
G3516
2834387
LINES GP-WATER
G3516
G3516
2781337
LINES GP-WATER
G3508, G3516, G3516B, G3520B
G3508, G3516, G3516B, G3520B
1740702
LINES GP-WATER
G3516, G3516B
G3516, G3516B
1679212
LINES GP-WATER
G3516
G3516
2152581
LINES GP-FUEL
G3516
G3516
1700986
LINES GP-FUEL
G3516
G3516
3282647
LINES GP-AIR
G3516, G3516B
G3516, G3516B
2057263
LINES GP-AIR
G3516
G3516
1676794
LINES GP-AIR
G3516
G3516
1654089
LINES GP-AIR
G3516, G3516B
G3516, G3516B