1152165 LINING GP- Caterpillar parts
Rating:
Alternative (cross code) number:
CA1152165
115-2165
1152165
CA1152165
115-2165
1152165
Weight: 4 pounds 1 kg.
Information:
Removal Procedure
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification marks on all hose assemblies for installation purposes. Plug all hose assemblies. This helps to prevent fluid loss, and this helps to keep contaminants from entering the system.
Illustration 1 g01523578
Open door assembly (2). Raise hood assembly (1).
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the procedure. Refer to Special Publication, NEDG2500, "Air Conditioning Tools" for the correct tools.
Illustration 2 g01525051
Remove bolts (3). Disconnect hose assemblies (4).
Loosen bolts (6). Remove refrigerant receiver-dryer (5). Installation Procedure
Illustration 3 g01525051
Position refrigerant receiver-dryer (5). Tighten bolts (6) to a torque of 20 5 N m (15 4 lb ft).
Connect hose assemblies (4). Install bolts (3). Tighten bolts (3) to a torque of 5.5 1.5 N m (48 13 lb in).
Charge the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG2500, "Air Conditioning Tools" for the correct tools.
Illustration 4 g01523578
Lower hood assembly (1). Close door assembly (2).
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification marks on all hose assemblies for installation purposes. Plug all hose assemblies. This helps to prevent fluid loss, and this helps to keep contaminants from entering the system.
Illustration 1 g01523578
Open door assembly (2). Raise hood assembly (1).
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the procedure. Refer to Special Publication, NEDG2500, "Air Conditioning Tools" for the correct tools.
Illustration 2 g01525051
Remove bolts (3). Disconnect hose assemblies (4).
Loosen bolts (6). Remove refrigerant receiver-dryer (5). Installation Procedure
Illustration 3 g01525051
Position refrigerant receiver-dryer (5). Tighten bolts (6) to a torque of 20 5 N m (15 4 lb ft).
Connect hose assemblies (4). Install bolts (3). Tighten bolts (3) to a torque of 5.5 1.5 N m (48 13 lb in).
Charge the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG2500, "Air Conditioning Tools" for the correct tools.
Illustration 4 g01523578
Lower hood assembly (1). Close door assembly (2).
Parts lining Caterpillar catalog:
1152164
LINING GP-
Caterpillar
Caterpillar
1152163
LINING GP
Caterpillar
Caterpillar
1151928
LINING-BRAKE
Caterpillar
Caterpillar
1147420
LINING
Caterpillar
Caterpillar
1135842
LINING KIT
Caterpillar
Caterpillar
1115349
LINING
Caterpillar
Caterpillar
1485980
LINING
Caterpillar
Caterpillar
1485979
LINING
Caterpillar
Caterpillar
1480474
LINING-CLUTCH
Caterpillar
Caterpillar
1328055
LINING-BRAKE
Caterpillar
Caterpillar
1157146
LINING AR-
Caterpillar
Caterpillar
1152166
LINING GP-
Caterpillar
Caterpillar