2885754 LINK AS.-TCK- Caterpillar parts
Rating:
Alternative (cross code) number:
CA2885754
288-5754
2885754
CA2885754
288-5754
2885754
Weight: 2068 pounds 938 kg.
Information:
Illustration 1 g01136937
Schematic of the Automatic Lubrication RelayThis diagnostic code is associated with the autolube relay. The FMI 06 means that the ECM has determined that the current of the relay is above normal. The possible causes of this diagnostic code are listed:
The energize circuit of the relay is shorted to ground.
The relay has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0558 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the machine ECM will be unable to control the autolube relay. The machine ECM reads the current of the relay circuit as being above normal, short circuit to ground. This fault will cause the autolube relay to be disabled at all times or this fault will cause the autolube relay to operate intermittently. Test Step 1. CHECK THE RELAY.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the relay with the active diagnostic code from the machine harness. Expected Result:CID 0558 FMI 06 changes to CID 0558 FMI 05 when the relay is disconnected.Results:
YES - CID 0558 FMI 06 changes to CID 0558 FMI 05 when the relay is disconnected. The circuit is correct.Repair: The relay has failed. Repeat this test "CHECK THE RELAY" in order to verify the failure of the relay. Replace the relay. Stop.
NO - CID 0558 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE RELAY FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The relay remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-44 (wire 801-PK) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-44 (wire 801-PK) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0558 FMI 06. Expected Result:The CID 0558 FMI 06 is active. Results:
YES - The CID 0558 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair:
Parts link Caterpillar catalog:
2883705
LINK AS.-TCK-
Caterpillar
Caterpillar
2883694
LINK AS.-TCK-
Caterpillar
Caterpillar
2883693
LINK AS.-TCK-
Caterpillar
Caterpillar
2882134
LINK AS-BRG &
Caterpillar
Caterpillar
2876154
LINK AS
Caterpillar
Caterpillar
2873119
LINK-TCK LH-
Caterpillar
Caterpillar
2893396
LINK AS.
Caterpillar
Caterpillar
2890634
LINK-TCK-LH-
Caterpillar
Caterpillar
2890633
LINK-TCK-RH-
Caterpillar
Caterpillar
2889952
LINK AS.-TRACK
Caterpillar
Caterpillar
2888893
LINK AS.-TRACK
Caterpillar
Caterpillar
2885755
LINK AS.-TCK-
Caterpillar
Caterpillar