Information:


Illustration 1 g01853834
Schematic of the start relayThis diagnostic code is associated with the start relay. The FMI 03 means that the ECM has determined that the voltage of the relay circuit is above normal.The possible causes of the diagnostic code are listed:
The relay has failed.
The energizer circuit of the relay is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0444 FMI 03 is active before performing this procedure.Note: Use a calibrated Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the ECM will turn off the current to the failed relay.Test Step 1. CHECK THE ENERGIZER CIRCUIT OF THE RELAY FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the relay and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J1-8 (wire 306-GN) to all contacts that are used in the machine harness connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-8 (306-GN) and the circuit that has a low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Perform the following:
Inspect the contacts of the harness connectors.
Clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch to the ON position.
Turn the key start switch to the ON position.
Operate the machine.
Determine if the CID 0444 FMI 03 is active.Expected Result:The CID 0444 FMI 03 is active.Results:
OK - The CID 0444 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See the Testing and Adjusting, "Electronic Control Module (ECM) - Replace" Story in this manual for additional information.STOP
NOT OK - The CID 0444 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP