5B6390 LINK (CONNECTING) Caterpillar parts
120, 12E, 12F, 140G, 14E
Rating:
Alternative (cross code) number:
CA5B6390
5B-6390
5B6390
CA5B6390
5B-6390
5B6390
Weight: 0.80 pounds 0 kg.
MOTOR GRADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$23.44
11 Jan 2022
US: Florida-Parts-Z
5B6390 - Link (Connecting) 2Y3884 2Y2525 160H for Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Information:
Analog Outputs - General Information
Table 1 shows the characteristics for the analog outputs that are supported by the OCP.Each analog output can be configured for either voltage or current use.
Table 1
Characteristic Description
Number of analog outputs 3
Conductors used for each output 2 (plus shield)
Type of output channel isolated
Current range 0 to 20 mA
4 to 20 mA
0mA to 10mA
Voltage Range 0 to 5 v
1 to 5 v
0V to 10V
-3V to +3V
-2.5V to +2.5V
-5V to +5V
-10V to +10V
0.5 to 4.5V
-1V to +1V
Full resolution Minimum of 8 bits (256 points) of data Each analog output contains a parameter that is called "Data Identifications". Any analog output can be configured for any one of the data identifications listed in Table 2.
Table 2
Valid Data Identifications
GOV DESIRED ENG SPEED
ENGINE SPEED
ENGINE COOLANT TEMP
UREA LEVEL
ENG OIL TEMP CUSTOM PARAMETER #1
CUSTOM PARAMETER #2
CUSTOM PARAMETER #3
OUTPUT FROM SCADA
ENGINE FUEL LEVEL Viewing the Current Analog Output Status
Use the following steps to view the status of an analog output.
Illustration 1 g02270495
Use the navigation keys in order to select "VIEW" at the main menu screen. Refer to Illustration 1.
Press the "OK" key.
Illustration 2 g03005778
Use the navigation keys in order to select "I/O STATUS" at the view screen. Refer to Illustration 2.
Press the "OK" key.
Illustration 3 g02270497
Use the navigation keys in order to select "ANALOG OUTPUTS" at the I/O status screen. Refer to Illustration 3.
Press the "OK" key.
Illustration 4 g02270499
The status of each analog output is shown in Illustration 4. A "dash" under an output number indicates the output is programmed, but is inactive. A large "X" under an output number indicates the output is disabled. A number under an output number indicates the output is programmed and is active.
Use the navigation keys in order to select the desired analog output that is to be viewed. Press the "OK" key.
Illustration 5 g02270500
The settings that have been configured will be displayed. Illustration 5 shows the settings for usage type, range, minimum data and maximum data of the selected analog output. Programming Analog Outputs Using the Display
Configuring Analog Outputs for Voltage Mode
The following steps provide information about using the OCP display to configure an analog output for voltage mode.
Table 1 shows the characteristics for the analog outputs that are supported by the OCP.Each analog output can be configured for either voltage or current use.
Table 1
Characteristic Description
Number of analog outputs 3
Conductors used for each output 2 (plus shield)
Type of output channel isolated
Current range 0 to 20 mA
4 to 20 mA
0mA to 10mA
Voltage Range 0 to 5 v
1 to 5 v
0V to 10V
-3V to +3V
-2.5V to +2.5V
-5V to +5V
-10V to +10V
0.5 to 4.5V
-1V to +1V
Full resolution Minimum of 8 bits (256 points) of data Each analog output contains a parameter that is called "Data Identifications". Any analog output can be configured for any one of the data identifications listed in Table 2.
Table 2
Valid Data Identifications
GOV DESIRED ENG SPEED
ENGINE SPEED
ENGINE COOLANT TEMP
UREA LEVEL
ENG OIL TEMP CUSTOM PARAMETER #1
CUSTOM PARAMETER #2
CUSTOM PARAMETER #3
OUTPUT FROM SCADA
ENGINE FUEL LEVEL Viewing the Current Analog Output Status
Use the following steps to view the status of an analog output.
Illustration 1 g02270495
Use the navigation keys in order to select "VIEW" at the main menu screen. Refer to Illustration 1.
Press the "OK" key.
Illustration 2 g03005778
Use the navigation keys in order to select "I/O STATUS" at the view screen. Refer to Illustration 2.
Press the "OK" key.
Illustration 3 g02270497
Use the navigation keys in order to select "ANALOG OUTPUTS" at the I/O status screen. Refer to Illustration 3.
Press the "OK" key.
Illustration 4 g02270499
The status of each analog output is shown in Illustration 4. A "dash" under an output number indicates the output is programmed, but is inactive. A large "X" under an output number indicates the output is disabled. A number under an output number indicates the output is programmed and is active.
Use the navigation keys in order to select the desired analog output that is to be viewed. Press the "OK" key.
Illustration 5 g02270500
The settings that have been configured will be displayed. Illustration 5 shows the settings for usage type, range, minimum data and maximum data of the selected analog output. Programming Analog Outputs Using the Display
Configuring Analog Outputs for Voltage Mode
The following steps provide information about using the OCP display to configure an analog output for voltage mode.
Caterpillar parts catalog:
Parts link Caterpillar catalog:
8W3589
LINK AS-SPRING
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
6G1631
LINK-CONNECTING
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H, 163H NA
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H, 163H NA
1D4494
LINK-BLADE TILT
120, 120G, 130G
120, 120G, 130G
7D2267
LINK ASSEM.
120, 120B, 140, 140B
120, 120B, 140, 140B
2F9074
LINK
120, 120B, 12E
120, 120B, 12E
2D0236
LINK
12E
12E
2D7715
LINK
12E
12E
9F2587
LINK
12E
12E
4H2441
LINK
12E
12E
3D8701
LINK
12E
12E
2D8701
LINK
12E
12E
5D8173
LINK
14E
14E
6D4109
LINK
14E
14E
4D1603
LINK
120, 120B, 12E, 140, 140B, 14E
120, 120B, 12E, 140, 140B, 14E
2Y2279
LINK
120B, 140B
120B, 140B
6D6942
LINK ASSEM.
120, 120B, 140, 140B, 16G
120, 120B, 140, 140B, 16G
3957088
LINK AS-BEARING
MH3059
MH3059
3957086
LINK AS-BEARING
MH3059
MH3059
7D2438
LINK ASSEM.
120, 140B
120, 140B
7D2267
LINK ASSEM.
120, 120B, 140, 140B
120, 120B, 140, 140B
7B2570
LINK
12F, 14E
12F, 14E
6D9987
LINK
14E
14E
5B6401
LINK(CONNECTING)
120, 12E, 12F, 140G
120, 12E, 12F, 140G
5B6379
LINK (ROLLER)
120, 12E, 12F, 130G, 140G, 14E
120, 12E, 12F, 130G, 140G, 14E