Schematic for the Pilot On/Off Solenoid ValveThis diagnostic code is recorded when the ECM detects a short to ground in the electrical path from the ECM to the solenoid. The possible causes for this diagnostic code are listed:
The internal windings for the solenoid have low impedance.
The internal windings for the solenoid are shorted.
The signal circuit from the ECM to the solenoid is shorted to ground.System Response:The machine response is listed:
The implement features will not operate.
The pilot on/off solenoid valve is off.Note: All solenoid return lines connect to contact J2-4 (wire K927-BU) of the implement ECM.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code is corrected. Note: Ensure that the diagnostic code indicator is active and that the diagnostic code is active.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position.
Observe the ON/OFF status of the diagnostic code indicator.
Disconnect the solenoid with the diagnostic code from the harness.Expected Result:The diagnostic code indicator remains active.Results:
YES - The diagnostic code indicator remains active and the diagnostic code remains active. The harness has failed or the ECM has failed. Proceed to Test Step 2.
NO - The diagnostic code indicator is inactive.Repair: The solenoid has failed or the connecting harness has failed. Repeat this test in order to verify the failure. Repair the solenoid or replace the solenoid. Repair the connecting harness or replace the connecting harness at the solenoid. Stop.Test Step 2. CHECK FOR A SHORTED HARNESS.
Turn the disconnect switch to the OFF position.
The solenoid valve from the previous test step remains disconnected.
Disconnect the harness from the implement ECM.
At the harness connector for the ECM, measure the resistance between contact for the failed solenoid circuit J1-12 (wire H717-BR) and contact J2-4 (ground wire K927-BU).Expected Result:The resistance is less than 5000 Ohms.Results:
YES - The resistance is less than 5000 Ohms.Repair: The harness has failed. The corresponding solenoid wire is shorted to ground in the harness. Repair the harness or replace the harness. Stop.
NO - Resistance is greater than 5000 Ohms (no continuity).Repair: The harness circuit resistance is correct. It is unlikely that the ECM has failed. Exit this procedure and perform this troubleshooting procedure again. Also recheck if the diagnostic code indicator is active for this diagnostic code. If the cause is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
Caterpillar parts catalog:
Parts link Caterpillar catalog:
2726010
LINK AS-TRACK
D8R, D8R II, D8T
D8R, D8R II, D8T
2433375
LINK AS
D8R, D8R II
D8R, D8R II
1058177
LINK AS
D8R
D8R
2024981
LINK AS
D8R, D8R II
D8R, D8R II
2433371
LINK AS
D8R, D8R II
D8R, D8R II
2393341
LINK AS
D8R, D8T
D8R, D8T
3045680
LINK-TRACK
D8R, D8T
D8R, D8T
2564902
LINK AS
D8R, D8T
D8R, D8T
2611175
LINK AS-WIPER
D10T, D11T, D8T, D9T
D10T, D11T, D8T, D9T
2611176
LINK AS
D10T, D11T, D8T, D9T
D10T, D11T, D8T, D9T
8E4060
LINK-TRACK MASTER
D8N, D8R, D8R II, D8T
D8N, D8R, D8R II, D8T
7T4761
LINK AS
D10N, D10R, D11N, D11R, D9L, D9N, D9R
D10N, D10R, D11N, D11R, D9L, D9N, D9R
2504244
LINK-TRACK MASTER
D9R, D9T
D9R, D9T
2504243
LINK-TRACK MASTER
D9R, D9T
D9R, D9T
2504248
LINK-TRACK MASTER
D9R, D9T
D9R, D9T
2504247
LINK-TRACK MASTER
D9R, D9T
D9R, D9T
1058177
LINK AS
D8R
D8R
2433375
LINK AS
D8R, D8R II
D8R, D8R II
2189951
LINK AS
D8R, D8R II
D8R, D8R II
2044254
LINK AS
D8R, D8R II
D8R, D8R II
4Z9386
LINK AS
D8R, D8R II
D8R, D8R II