8E4519 LINK-TRACK-RH Caterpillar parts
D8L
Rating:
Alternative (cross code) number:
CA8E4519
8E-4519
8E4519
CA8E4519
8E-4519
8E4519
Weight: 21 pounds 9 kg.
TRACK-TYPE TRACTOR,
Compatible equipment models: 8E4519:
Information:
Illustration 1 g02575881
Schematic for the Left Valve Pressure Sensor
This diagnostic code is associated with the Left Valve Pressure Sensor. The FMI 04 means that the ECM has determined that the signal of the sensor is below the normal range.The output frequency of the pressure sensor is approximately 500 hertz. The duty cycle of the signal changes as the pressure changes.The possible causes of this diagnostic code are listed below:
The signal circuit for the sensor is shorted to ground.
The sensor has failed.
The ECM has failed. This situation is unlikely.Note: The following test procedure may create other diagnostic codes. Clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2415 FMI 04 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The diagnostic code will be logged into the internal memory of the ECM.Test Step 1. CHECK THE SENSOR
Turn the disconnect switch and the key start switch to the ON position.
Ensure that the diagnostic code is active.
Observe the status of the diagnostic code. Disconnect the sensor from the machine harness. Expected Result:The CID 2415 FMI 04 diagnostic code remains active. The FMI has not changed and the FMI 04 diagnostic code is still active.Results:
OK - The diagnostic code remains active. The sensor is correct. Proceed to Test Step 2.
NOT OK - The diagnostic code is no longer active. The sensor has failed.Repair: Replace the sensor.STOPTest Step 2. CHECK THE WIRING HARNESS OF THE SENSOR FOR A SHORT TO GROUND
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the sensor.
Disconnect the machine harness connectors from the ECM.
Operate the machine and take the sensor through the operating range of the sensor.
At the machine harness connector for the ECM, measure the resistance from the signal contact "J2-51" (wire M921-BR(Brown)) of the machine harness to all possible sources of ground. Measure the resistance to all contacts of the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - One or more resistance measurements are not correct. There is a short in the machine harness. Repair: The short is between signal contact "J2-51" (wire M921-BR(Brown)) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS
Inspect the contacts of the harness connectors and clean the contacts.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 2415 FMI 04 diagnostic code. Expected Result:The CID 2415 FMI 04 diagnostic code is active.Results:
OK - The CID 2415 FMI 04 diagnostic code is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: Failure of the ECM is unlikely. Exit this procedure and perform this procedure again.
Caterpillar parts catalog:
Parts link Caterpillar catalog:
7T2212
LINK
578, D8L, D8N
578, D8L, D8N
3G6766
LINK AS
D8L
D8L
4T9446
LINK AS
D8L
D8L
7G6024
LINK
D8L
D8L
7G6023
LINK
D8L
D8L
7G6021
LINK
D8L
D8L
7G6022
LINK
D8L
D8L
1U1205
LINK
D8L
D8L
7T3837
LINK AS
D8N
D8N
3G3371
LINK AS-TAG
825C
825C
6Y1561
LINK AS
D11N
D11N
6T0304
LINK AS
D10, D8L, D9L
D10, D8L, D9L
5H4575
LINK
D9E
D9E
5H7545
LINK
D9E
D9E