Information:
Illustration 1 g01145169
Schematic of the transmission solenoid 3
This diagnostic code is associated with the transmission solenoid 3. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal. The possible causes of the diagnostic code are listed:
The solenoid has failed
The energize circuit of the solenoid is shorted to the +battery circuit
The ECM may have failed, but is unlikelyNote: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1403 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code occurs, only the gears that use the solenoids that have faults are not available.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J1-66 (wire 754-BU(Blue)) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5 ohms. Results:
YES - Each resistance measurement is greater than 5 ohms. The machine harness is correct. Proceed to Test Step 2.
NO - Each resistance measurement is not greater than 5 ohms. There is a short in the machine harness. The short is between J1-66 (754-BU(Blue)) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1403 FMI 03 is active. Expected Result:The CID 1403 FMI 03 is active.Results:
YES - The CID 1403 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: The ECM is unlikely to have failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. Refer to Troubleshooting, Testing and Adjusting, "Electronic Control Module (ECM) - Replace" for the machine that is being serviced.STOP
NO - The CID 1403 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by:
A poor electrical connection
A short at one of the harness connectors that was disconnected and reconnectedResume normal machine operation.STOP
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts link Caterpillar catalog:
8Y2203
LINK AS
963, 963B, 963C
963, 963B, 963C
8Y2204
LINK AS
963, 963B, 963C
963, 963B, 963C
8G1566
LINK ASSEM.
963, 973
963, 973
3W8404
LINK AS
963
963
4T9447
LINK GP-STABILIZER
D8L, D9N
D8L, D9N
4T0198
LINK GP
D8L
D8L
5T8700
LINK GP
785
785
1171023
LINK AS-TRACK
963, 963B, 963C
963, 963B, 963C