Which Generate This Code:This diagnostic code is usually associated with EUI applications. The CID 0590 failure means that the engine electronic control module has stopped responding to the periodic requests for information from the GSC+.Note: This diagnostic code may occur on an MUI application. The diagnostic code is caused by an incorrectly programmed P023 setpoint. For MUI applications, the setpoint P023of GSC+ must be set to 0. Reprogram the setpoint and other GSC+ setpoints. See Systems Operation, "Engine/Generator Programming OP5-0".Test Step 1. CHECK THE CAT DATA LINK
Turn the ECS to OFF/RESET position.
Disconnect the contacts 19 and 20 of the CAT data link from the GSC+.
Disconnect the contacts 13 and 14 of the CAT data link from the ECM.
Measure the resistance between contact 19 of the GSC+ and contact 14 of the ECM.
Measure the resistance between contact 20 of the GSC+ and contact 13 of the ECM.Expected Result:The resistance for both measurements is less than 5 ohms.Results:
OK - The resistance for both measurements is less than 5 ohms. The circuit is correct. The ECM has failed.Repair: It is unlikely that the ECM has failed. See Troubleshooting, SENR1003, "3500B EPG Engines" or Troubleshooting, RENR2227, "3406E EPG Engines" prior to replacing the ECM. Clear the diagnostic code from the fault log after troubleshooting is complete. The GSC+ is usually programmed to treat a CID 590 diagnostic code as an "alarm fault". Setpoint P04 is 0. If the GSC is programmed to treat this code as a shutdown fault, setpoint P04 is 1. Then, it is not necessary to press the "alarm codes" key in order to see the diagnostic code. The diagnostic code is automatically shown on the upper display.STOP
NOT OK - The resistance for both measurements is greater than 5 ohms. The circuit is not correct.Repair: Repair the wiring of the CAT data link or replace the wiring of the CAT data link.Clear the diagnostic code from the fault log after troubleshooting is complete. The GSC+ is usually programmed to treat a CID 590 diagnostic code as an "alarm fault". Setpoint P04 is 0. If the GSC is programmed to treat this code as a shutdown fault, setpoint P04 is 1. Then, it is not necessary to press the "alarm codes" key in order to see the diagnostic code. The diagnostic code is automatically shown on the upper display.STOP
Turn the ECS to OFF/RESET position.
Disconnect the contacts 19 and 20 of the CAT data link from the GSC+.
Disconnect the contacts 13 and 14 of the CAT data link from the ECM.
Measure the resistance between contact 19 of the GSC+ and contact 14 of the ECM.
Measure the resistance between contact 20 of the GSC+ and contact 13 of the ECM.Expected Result:The resistance for both measurements is less than 5 ohms.Results:
OK - The resistance for both measurements is less than 5 ohms. The circuit is correct. The ECM has failed.Repair: It is unlikely that the ECM has failed. See Troubleshooting, SENR1003, "3500B EPG Engines" or Troubleshooting, RENR2227, "3406E EPG Engines" prior to replacing the ECM. Clear the diagnostic code from the fault log after troubleshooting is complete. The GSC+ is usually programmed to treat a CID 590 diagnostic code as an "alarm fault". Setpoint P04 is 0. If the GSC is programmed to treat this code as a shutdown fault, setpoint P04 is 1. Then, it is not necessary to press the "alarm codes" key in order to see the diagnostic code. The diagnostic code is automatically shown on the upper display.STOP
NOT OK - The resistance for both measurements is greater than 5 ohms. The circuit is not correct.Repair: Repair the wiring of the CAT data link or replace the wiring of the CAT data link.Clear the diagnostic code from the fault log after troubleshooting is complete. The GSC+ is usually programmed to treat a CID 590 diagnostic code as an "alarm fault". Setpoint P04 is 0. If the GSC is programmed to treat this code as a shutdown fault, setpoint P04 is 1. Then, it is not necessary to press the "alarm codes" key in order to see the diagnostic code. The diagnostic code is automatically shown on the upper display.STOP
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts link Caterpillar catalog:
9S1928
LINK-TRACK-LH
245, 245B, 594, 594H, D9E, D9G, D9H
245, 245B, 594, 594H, D9E, D9G, D9H
9S1927
LINK-TRACK-RH
245, 245B, 594, 594H, D9E, D9G, D9H
245, 245B, 594, 594H, D9E, D9G, D9H
8V2333
LINK AS
215, 227, 229, 235C, 245, 245B
215, 227, 229, 235C, 245, 245B
4T1942
LINK-PISTON
235, 245, 245D
235, 245, 245D
4T1115
LINK-PISTON
16G, 225, 227, 235D, 245, 245B, 245D
16G, 225, 227, 235D, 245, 245B, 245D
2V0821
LINK
245
245
2V0820
LINK
245
245
3V9125
LINK
245
245
3V9126
LINK
245
245
9V2343
LINK AS
245
245
9V2079
LINK
245
245
3G9708
LINK-PISTON
231D, 235D, 973
231D, 235D, 973
9U9395
LINK AS-TRACK
D6H, D6R
D6H, D6R
4312186
LINK AS-TRACK
325D FM
325D FM
3122274
LINK AS-TRACK
D5C III, D5G
D5C III, D5G
2564901
LINK GP-STABILIZER
D8R, D8T
D8R, D8T
3690853
LINK AS-TRACK
325D FM, 325D FM LL
325D FM, 325D FM LL
3012307
LINK AS-TRACK
325D FM, 325D FM LL, 330D FM, 345D, 345D L, 349D, 349E, 568 FM LL
325D FM, 325D FM LL, 330D FM, 345D, 345D L, 349D, 349E, 568 FM LL
8R0657
LINK GP
65, 75
65, 75
6R0199
LINK GP-STEERING
AP-1000
AP-1000