9S8313 LINK A Caterpillar parts
Rating:
Alternative (cross code) number:
CA9S8313
9S-8313
9S8313
CA9S8313
9S-8313
9S8313
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
3216-11
Aftertreatment #1 Intake NOx : Other Failure Mode 3655-11
Aftertreatment #1 Intake NOx Level Sensor : Other Failure Mode The #1 intake NOx sensor heater cannot generate enough heat or the power supply is intermittent.
3216-12
Aftertreatment #1 Intake NOx : Failure 3655-12
Aftertreatment #1 Intake NOx Level Sensor : Failure A failed #1 intake NOx sensor has been detected.
3226-11
Aftertreatment #1 Outlet NOx : Other Failure Mode 3609-11
Aftertreatment #1 Outlet #1 NOx Level Sensor : Other Failure Mode The #1 outlet NOx sensor heater cannot generate enough heat or the power supply is intermittent.
3226-12
Aftertreatment #1 Outlet NOx : Failure 3609-12
Aftertreatment #1 Outlet #1 NOx Level Sensor : Failure A failed #1 outlet NOx sensor has been detected.
3255-11
Aftertreatment #2 Intake NOx : Other Failure Mode 3656-11
Aftertreatment #2 Intake NOx Level Sensor : Other Failure Mode The #2 outlet NOx sensor heater cannot generate enough heat or the power supply is intermittent.
3255-12
Aftertreatment #2 Intake NOx : Failure 3656-12
Aftertreatment #2 Intake NOx Level Sensor : Failure A failed #2 outlet NOx sensor has been detected.
3265-11
Aftertreatment #2 Outlet NOx : Other Failure Mode 5141-11
Aftertreatment #1 Outlet #2 NOx Level Sensor : Other Failure Mode The #2 outlet NOx sensor heater cannot generate enough heat or the power supply is intermittent.
3265-12
Aftertreatment #2 Outlet NOx : Failure 5141-12
Aftertreatment #1 Outlet #2 NOx Level Sensor : Failure A failed #2 outlet NOx sensor has been detected.
3360-12
Aftertreatment #1 DEF Controller #1 : Failure 3820-12
Aftertreatment #1 DEF Controller : Failure The #1 DCU has been flashed or a failed #1 DCU has been detected.
4450-12
Aftertreatment #2 Diesel Exhaust Fluid Controller : Failure 4577-12
Aftertreatment #2 DEF Controller #1 : Failure The #2 intake NOx sensor heater cannot generate enough heat or the power supply is intermittent.
7538-12
Aftertreatment #1 Diesel Exhaust Fluid Controller #2 : Failure 4797-12
Aftertreatment #1 DEF Controller #2 : Failure The #2 DCU has been flashed or a failed #2 DCU has been detected.
7539-12
Aftertreatment #2 DEF Controller #2 : Failure 4798-12
Aftertreatment #2 DEF Controller #2 : Failure The #2 intake NOx sensor heater cannot generate enough heat or the power supply is intermittent. Note: Turn the keyswitch to the OFF position before connecting or disconnecting these components.If the Cat® Electronic Technician (ET) will not communicate with the Electronic Control Module (ECM), refer to Troubleshooting, "Electronic Service Tool Does Not Communicate" before you begin this procedure. The procedure verifies that electrical power is being supplied to the ECM and to the service tool connector.The data links are used to communicate information between the engine ECM and other control modules that are a part of the application. Cat ET also communicates with the ECM via the data links.The service tool connector contains connections for electrical power and for the data links.When the keyswitch is in the OFF position, Cat ET may communicate with the ECM. However, the communications may be disrupted and the communications may require frequent reconnection. To avoid this problem, place the keyswitch in the ON position when Cat ET is being used.Cat
Parts link Caterpillar catalog:
9S1380
LINK-FLYWHEEL
Caterpillar
Caterpillar
9R7826
LINK AS
Caterpillar
Caterpillar
9R6258
LINK AS
Caterpillar
Caterpillar
9R6257
LINK AS
Caterpillar
Caterpillar
9R6078
LINK AS
Caterpillar
Caterpillar
9R5983
LINK A-RH
Caterpillar
Caterpillar
9W6724
LINK AS-TRACK
Caterpillar
Caterpillar
9W6086
LINK A TRACK
Caterpillar
Caterpillar
9W5219
LINK AS
Caterpillar
Caterpillar
9W4185
LINK AS.
Caterpillar
Caterpillar
9W1886
LINK AS
Caterpillar
Caterpillar
9T6525
LINK A
Caterpillar
Caterpillar