1284374 LINKAGE GP-BUCKET Caterpillar parts
M320
Rating:
Alternative (cross code) number:
CA1284374
128-4374
1284374
CA1284374
128-4374
1284374
WHEELED EXCAVATOR,
Compatible equipment models: 1284374:
Information:
Illustration 1 g02711288
Schematic of the Parking Brake SolenoidThis diagnostic code is associated with the Parking Brake Solenoid. The FMI 05 means that the ECM has detected that the current for the solenoid circuit is below normal.Conditions that cause this diagnostic code to be activated are:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. The failure of the ECM is unlikely. Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. System Response:A Level 3 warning is generated.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Note: Fault detection is enabled only when the engine is running. Faults will not be detected if the engine is not running.Test Step 1. CHECK THE SOLENOID
Disconnect the solenoid from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire 777-PU) to contact 2 (wire 200-BK).
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the CID 0681 FMI 05 diagnostic code.Expected Result:The CID 0681 FMI 05 diagnostic code is no longer active. A CID 0681 FMI 06 diagnostic code becomes active when the jumper wire is connected.Results:
YES - The CID 0681 FMI 05 diagnostic code is no longer active. A CID 0681 FMI 06 diagnostic code becomes active when the jumper wire is connected. The solenoid has failed.Repair: Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The CID 0681 FMI 05 diagnostic code remains active. The jumper wire does not affect the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE CIRCUIT FOR AN OPENThe jumper wire that was installed in the previous Test Step remains in place.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness ECM connectors from the ECM.
At the machine harness connectors for the ECM, measure the resistance from contact C2-8 (wire 777-PU) to contact C1-1 (wire 200-BK).
While observing the multimeter resistance measurement, wiggle the machine harness connectors for the ECM and wiggle the machine harness connector for the solenoid. Gently pull on the wires and move the wires around.Expected Result:The resistance measurement is less than 5.0 ohms at all times during the manipulation of the harness and connectors.Results:
OK - The resistance measurement is less than 5.0 ohms. The resistance measurement is not indicating an open or
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts linkage Caterpillar catalog:
1332445
LINKAGE GP-BUCKET
322B, 322B L, 322B LN
322B, 322B L, 322B LN
1204964
LINKAGE AR-BUCKET
322B LN
322B LN
1332442
LINKAGE GP-BUCKET
330B, 330B L
330B, 330B L
1174117
LINKAGE AR-BUCKET
330B L
330B L
1317674
LINKAGE AR-BUCKET
320B, 320B L
320B, 320B L
1679857
LINKAGE GP-BUCKET
345B, 345B II, 345B L
345B, 345B II, 345B L
1679856
LINKAGE GP-BUCKET
345B, 345B II, 345B L
345B, 345B II, 345B L
1271351
LINKAGE GP-BUCKET
345B L
345B L
1970679
LINKAGE GP-BUCKET
988G, 988H
988G, 988H
1348862
LINKAGE GP-BUCKET
311B, 312B, 312B L, 313B
311B, 312B, 312B L, 313B