2A4465 LOCK Caterpillar parts
594, 594H, D9G, D9H
Rating:
Alternative (cross code) number:
CA2A4465
2A-4465
2A4465
CA2A4465
2A-4465
2A4465
Weight: 0.03 pounds 0 kg.
PIPELAYER, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$7.70
11 Apr 2023
Amazon.com
CTP 2A4465 Lock for Heavy Equipment
CTP Lock only || Sold in each || Easy in-and-out fit
CTP Lock only || Sold in each || Easy in-and-out fit
$6.89
13 Jul 2022
Amazon.com
CTP 2A4465 Lock for Heavy Equipment
CTP Lock only || Sold in each || Easy in-and-out fit
CTP Lock only || Sold in each || Easy in-and-out fit
Information:
Proper operation, driving techniques and maintenance are key factors in obtaining the maximum service life and economy of Caterpillar engines. The recommendations in this Operation and Maintenance Manual will help to lower operating costs. For more information, refer to Special Publication, LEDT2254, "CAT Answers Your Questions About Truck Performance" or consult your Caterpillar dealer.Idling
Idle speed is adjustable on Caterpillar electronic engines. Consult your Caterpillar dealer for information. The idle rpm is preset at 600 rpm.Avoid excess idling. If the vehicle is parked for more than five minutes, stop the engine. An engine can burn from 2.8 L (.7 US gal) to 5.7 L (1.5 US gal) of fuel per hour while the engine is idling. Excessive idling can cause carbon buildup and/or excessive idling can cause the engine to slobber. Excessive idling, carbon buildup, and engine slobber is harmful to the engine.If extended idle time is required, control the engine rpm to 1000 rpm or above 1000 rpm. Ensure that the coolant temperature exceeds 82° C (180° F), Consult your Caterpillar dealer for assistance.Fast idle can be programmed within the range of 700 rpm to the Top Engine Limit (TEL). Fast idle requires an "ON/OFF" switch on the dashboard. Consult your Caterpillar dealer for assistance.Idle Shutdown Timer
The idle shutdown timer can be programmed in order to shut down the engine after a specific time period of idling. The idle time can be programmed from one minute to 1440 minutes (24 hours). If the idle shutdown timer is set to 0 minutes, the idle shutdown feature is disabled. If the setting of the timer is unknown, allow the engine to idle. Observe the time that elapses before the engine shuts down. The following conditions must be met in order to activate the idle shutdown timer:
The idle shutdown feature must be selected.
No vehicle speed is detected by the Electronic Control Module (ECM).
The engine is not under load.
The engine is at operating temperature. The engine is not in Cold Mode.After the vehicle is stationary, the idle shutdown timer begins. The engine can be operating at low idle or at an idle rpm that is selected by the idle governor. The Check Engine/Diagnostic lamp will start to flash at a rapid rate (Driver alert) 30 seconds before the programmed idle time expires when the idle shutdown timer is programmed to one minute. The lamp will start to flash 90 seconds before the programmed idle time expires when the programmed idle time is 2 minutes or more. The flashing lamp alerts the driver the engine is about to shut down.The following conditions must be met in order to override the idle shutdown timer:
Program the "ALLOW IDLE SHUTDOWN OVERRIDE" to "YES".
The "CHECK ENGINE/DIAGNOSTIC" lamp will flash rapidly for 30 to 90 seconds prior to shutdown. The service brake or the clutch pedal must be depressed during the 30 to 90 seconds when the lamp is flashing. A diagnostic EVENT code for Override of the Idle Shutdown Timer will be logged in the ECM. Movement
Idle speed is adjustable on Caterpillar electronic engines. Consult your Caterpillar dealer for information. The idle rpm is preset at 600 rpm.Avoid excess idling. If the vehicle is parked for more than five minutes, stop the engine. An engine can burn from 2.8 L (.7 US gal) to 5.7 L (1.5 US gal) of fuel per hour while the engine is idling. Excessive idling can cause carbon buildup and/or excessive idling can cause the engine to slobber. Excessive idling, carbon buildup, and engine slobber is harmful to the engine.If extended idle time is required, control the engine rpm to 1000 rpm or above 1000 rpm. Ensure that the coolant temperature exceeds 82° C (180° F), Consult your Caterpillar dealer for assistance.Fast idle can be programmed within the range of 700 rpm to the Top Engine Limit (TEL). Fast idle requires an "ON/OFF" switch on the dashboard. Consult your Caterpillar dealer for assistance.Idle Shutdown Timer
The idle shutdown timer can be programmed in order to shut down the engine after a specific time period of idling. The idle time can be programmed from one minute to 1440 minutes (24 hours). If the idle shutdown timer is set to 0 minutes, the idle shutdown feature is disabled. If the setting of the timer is unknown, allow the engine to idle. Observe the time that elapses before the engine shuts down. The following conditions must be met in order to activate the idle shutdown timer:
The idle shutdown feature must be selected.
No vehicle speed is detected by the Electronic Control Module (ECM).
The engine is not under load.
The engine is at operating temperature. The engine is not in Cold Mode.After the vehicle is stationary, the idle shutdown timer begins. The engine can be operating at low idle or at an idle rpm that is selected by the idle governor. The Check Engine/Diagnostic lamp will start to flash at a rapid rate (Driver alert) 30 seconds before the programmed idle time expires when the idle shutdown timer is programmed to one minute. The lamp will start to flash 90 seconds before the programmed idle time expires when the programmed idle time is 2 minutes or more. The flashing lamp alerts the driver the engine is about to shut down.The following conditions must be met in order to override the idle shutdown timer:
Program the "ALLOW IDLE SHUTDOWN OVERRIDE" to "YES".
The "CHECK ENGINE/DIAGNOSTIC" lamp will flash rapidly for 30 to 90 seconds prior to shutdown. The service brake or the clutch pedal must be depressed during the 30 to 90 seconds when the lamp is flashing. A diagnostic EVENT code for Override of the Idle Shutdown Timer will be logged in the ECM. Movement
Cat SIS web machinery list:
Parts lock Caterpillar catalog:
1M7940
LOCK
163, 183B, 191, 50, D9E, D9G, D9H
163, 183B, 191, 50, D9E, D9G, D9H
3S8744
LOCK
571G, 572G, 583K, 594, 594H, 983B, D7G, D7G2, D8H, D8K, D9G, D9H
571G, 572G, 583K, 594, 594H, 983B, D7G, D7G2, D8H, D8K, D9G, D9H
1M4180
LOCK
594, 594H, D8H, D8K, D9G, D9H
594, 594H, D8H, D8K, D9G, D9H
4H0573
LOCK
594H, D9E, D9G, D9H
594H, D9E, D9G, D9H
5B7617
LOCK
594H, 651, D8H, D8K, D9G, D9H
594H, 651, D8H, D8K, D9G, D9H
6B0710
LOCK
D9E, D9H
D9E, D9H
9M5000
LOCK
16, 572G, 594, 594H, D7F, D7G, D8H, D8K
16, 572G, 594, 594H, D7F, D7G, D8H, D8K
2M4450
LOCK
594, 594H, D9G, D9H
594, 594H, D9G, D9H
9M3769
LOCK
594, 594H, D9G, D9H
594, 594H, D9G, D9H
5S3618
LOCK
57, 58, 594H, 844, 844H, 844K, 854G, 854K, 920, 930, 980, 980B, 990, 990 II, 990H, 990K, 992C, 992D, 992G, 992K, 993K, D10N, D10R, D7G, D8L, D9L, D9N
57, 58, 594H, 844, 844H, 844K, 854G, 854K, 920, 930, 980, 980B, 990, 990 II, 990H, 990K, 992C, 992D, 992G, 992K, 993K, D10N, D10R, D7G, D8L, D9L, D9N
8S5445
LOCK
D9G, D9H
D9G, D9H
5F9963
LOCK
16, 621, 621B, 623B, 627, 627B, 630B, 631B, 631C, 631D, 633D, 637, 637B, 637D, 639D, 641B, 650B, 651, 651B, 657, 657B, 666, 769, 834, 992, D8H, D9G
16, 621, 621B, 623B, 627, 627B, 630B, 631B, 631C, 631D, 633D, 637, 637B, 637D, 639D, 641B, 650B, 651, 651B, 657, 657B, 666, 769, 834, 992, D8H, D9G
7B3770
LOCK
910, 931, 931B, D3, D3B, IT12
910, 931, 931B, D3, D3B, IT12
6S3210
LOCK
931, D3
931, D3
6S4520
LOCK
931, D3
931, D3
9M5000
LOCK
16, 572G, 594, 594H, D7F, D7G, D8H, D8K
16, 572G, 594, 594H, D7F, D7G, D8H, D8K
6B0710
LOCK
D9E, D9H
D9E, D9H
9M2573
LOCK
D6C
D6C
2M4470
LOCK
594, 594H, D9G, D9H
594, 594H, D9G, D9H
9M3769
LOCK
594, 594H, D9G, D9H
594, 594H, D9G, D9H
2M4450
LOCK
594, 594H, D9G, D9H
594, 594H, D9G, D9H
7S7646
LOCK
594, 594H, D9G, D9H
594, 594H, D9G, D9H
2M4483
LOCK
594, D9G, D9H
594, D9G, D9H
8M2882
LOCK
594, 594H, D9G, D9H
594, 594H, D9G, D9H