3B1472 LOCK Caterpillar parts
571G, 572G, 983, D7F, D7G, D7G2
Rating:
Alternative (cross code) number:
CA3B1472
3B-1472
3B1472
CA3B1472
3B-1472
3B1472
Weight: 0.15 pounds 0 kg.
PIPELAYER, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$6.43
20 Aug 2022
Amazon.com
CTP 3B1472 Lock Nut for Heavy Equipment
CTP Locking Nut Only || Sold in each || Easy in-and-out fit || Country of origin: United States
CTP Locking Nut Only || Sold in each || Easy in-and-out fit || Country of origin: United States
$4.92
21 Jul 2022
US: TakePart
CTP 3B1472 Lock Nut for Heavy Equipment
CTP Locking Nut Only || Sold in each || Easy in-and-out fit || Country of origin: United States
CTP Locking Nut Only || Sold in each || Easy in-and-out fit || Country of origin: United States
Compatible equipment models: 3B1472:
Information:
System Operation Description:The event code, 4012-31 for utility breaker failure to close will become active when the following occurs:
The utility breaker or contactor does not change state after the EMCP has requested it to close.The EMCP has activated the digital output designated for the utility breaker. The utility breaker position is not being detected as closed at the digital inputs for Utility Breaker AUX A and/or AUX B.
View active and logged diagnostic codes to determine if there are any other diagnostics that may indicate a problem with the system which may lead to a transfer failure.
Verify EMCP set point for "Utility Breaker Maximum Close Time" event timer limits. Ensure that the timer is set to the appropriate time allotted to complete system transfer.
Wiring: Inspect system wiring for intermittent open circuits and high resistance, loose connections, and shorts to ground in between the EMCP relay or digital output. EMCP relay or digital output is designated for Utility breaker control to the Utility breaker.Test Step 1. Check the Wiring Harness for an Open Circuit or a Short Circuit to Ground
Disconnect battery power from the engine.
Disconnect the wiring harness from the EMCP and utility breaker.
Measure the resistance of the wiring between the designated relay or digital output and the utility breaker or utility breaker control device. If more than 10 ohms of resistance is found, there should be an open circuit or bad connection. Repair or replace the wiring. If less than 10 ohms of resistance is found, measure for battery voltage at the EMCP relay or digital output pin, and utility breaker connection point. If battery power is found at both points, there may be a problem with the utility breaker. If battery power is not present at the utility breaker but present at the EMCP, repair or replace the wiring in between the EMCP and breaker connections.Results:
- STOP
The utility breaker or contactor does not change state after the EMCP has requested it to close.The EMCP has activated the digital output designated for the utility breaker. The utility breaker position is not being detected as closed at the digital inputs for Utility Breaker AUX A and/or AUX B.
View active and logged diagnostic codes to determine if there are any other diagnostics that may indicate a problem with the system which may lead to a transfer failure.
Verify EMCP set point for "Utility Breaker Maximum Close Time" event timer limits. Ensure that the timer is set to the appropriate time allotted to complete system transfer.
Wiring: Inspect system wiring for intermittent open circuits and high resistance, loose connections, and shorts to ground in between the EMCP relay or digital output. EMCP relay or digital output is designated for Utility breaker control to the Utility breaker.Test Step 1. Check the Wiring Harness for an Open Circuit or a Short Circuit to Ground
Disconnect battery power from the engine.
Disconnect the wiring harness from the EMCP and utility breaker.
Measure the resistance of the wiring between the designated relay or digital output and the utility breaker or utility breaker control device. If more than 10 ohms of resistance is found, there should be an open circuit or bad connection. Repair or replace the wiring. If less than 10 ohms of resistance is found, measure for battery voltage at the EMCP relay or digital output pin, and utility breaker connection point. If battery power is found at both points, there may be a problem with the utility breaker. If battery power is not present at the utility breaker but present at the EMCP, repair or replace the wiring in between the EMCP and breaker connections.Results:
- STOP
Caterpillar parts catalog:
Parts lock Caterpillar catalog:
3S8744
LOCK
571G, 572G, 583K, 594, 594H, 983B, D7G, D7G2, D8H, D8K, D9G, D9H
571G, 572G, 583K, 594, 594H, 983B, D7G, D7G2, D8H, D8K, D9G, D9H
9M5000
LOCK
16, 572G, 594, 594H, D7F, D7G, D8H, D8K
16, 572G, 594, 594H, D7F, D7G, D8H, D8K
5M1994
LOCK
572G, 983, 983B, D7F, D7G, D7G2
572G, 983, 983B, D7F, D7G, D7G2
9S0712
LOCK
631C, 769, 824B, 825B, 983
631C, 769, 824B, 825B, 983
5M1993
LOCK
571G, 572G, 983, 983B, D7F, D7G, D7G2
571G, 572G, 983, 983B, D7F, D7G, D7G2
5M6646
LOCK
571G, 572G, 983, 983B, D7F, D7G
571G, 572G, 983, 983B, D7F, D7G
2S7594
LOCK
571G, 572G, 983, 983B, D7F, D7G, D7G2
571G, 572G, 983, 983B, D7F, D7G, D7G2
5S3618
LOCK
57, 58, 594H, 844, 844H, 844K, 854G, 854K, 920, 930, 980, 980B, 990, 990 II, 990H, 990K, 992C, 992D, 992G, 992K, 993K, D10N, D10R, D7G, D8L, D9L, D9N
57, 58, 594H, 844, 844H, 844K, 854G, 854K, 920, 930, 980, 980B, 990, 990 II, 990H, 990K, 992C, 992D, 992G, 992K, 993K, D10N, D10R, D7G, D8L, D9L, D9N
2S7066
LOCK
571G, 572G, D7F, D7G, D7G2
571G, 572G, D7F, D7G, D7G2
4H6506
LOCK
983, D7F
983, D7F
7S6774
LOCK
518, 627, 920, 930, 950, 966C, 980B, D7F
518, 627, 920, 930, 950, 966C, 980B, D7F
9S6764
LOCK
D7F
D7F
5M6647
LOCK
571G, 572G, 983, 983B, D7F, D7G
571G, 572G, 983, 983B, D7F, D7G
5M6646
LOCK
571G, 572G, 983, 983B, D7F, D7G
571G, 572G, 983, 983B, D7F, D7G
5M1993
LOCK
571G, 572G, 983, 983B, D7F, D7G, D7G2
571G, 572G, 983, 983B, D7F, D7G, D7G2
3A2031
LOCK ASSEM.
955L
955L
3F7404
LOCK
127, 25
127, 25
9S0712
LOCK
631C, 769, 824B, 825B, 983
631C, 769, 824B, 825B, 983
8A2790
LOCK
D6C
D6C
4M1697
LOCK
594, 594H, D9G, D9H
594, 594H, D9G, D9H
2M7042
LOCK
594, 594H, D9G, D9H
594, 594H, D9G, D9H
8S2506
LOCK
571G, 572G, 983, 983B, D7F, D7G, D7G2
571G, 572G, 983, 983B, D7F, D7G, D7G2
2S7594
LOCK
571G, 572G, 983, 983B, D7F, D7G, D7G2
571G, 572G, 983, 983B, D7F, D7G, D7G2
1P0934
LOCK
983, 983B
983, 983B