Information:
Illustration 7 g02208419
The monitor will begin to communicate with the ECM. This may take a few moments. When the communication link is established, the monitor will display the calibration screen.
Illustration 8 g02208420
(L) Lower limit (U) Upper limit (C) Current Value (S) "STEP NUMBER" and "STEP NAME"
After the OK key is pressed, the "CALIBRATION TITLE" will appear. The "CALIBRATION TITLE" screen allows the upper limitation and the lower limitation to be set. Refer to Illustration 8.Note: The title of the calibration and the name of the step will change in accordance to the procedure that is being performed. "CALIBRATION TITLE" and "STEP NAME" are used in this document as an example.Note: In the "CALIBRATION TITLE" screen, "STEP No" is displayed in blue. The "OPERATION GUIDANCE" will be displayed in green.
Illustration 9 g02208421
When a pressure gauge is connected to the pressure tap for extend solenoid (10), press the OK key (8) .Note: The "HYD OIL TEMP / ENGINE SPEED" screens are available during the process of calibration by pressing the up key (1) or the down key (6) .
Illustration 10 g02208422
Release all controls. When all controls are in the neutral position, press the OK key (8) .
Illustration 11 g02208424
Hold the attachment controls in the FORWARD position. Press the OK key (8) .
Illustration 12 g02208425
Press the right key (2) in order to increase the value. Press the left key (5) in order to decrease the value. Adjust the value until the gauge pressure is within the specification.
Press the device for activation 3 times and release the device for activation 3 times.Note: Pressing the device for activation three times ensures that an accurate reading will result.
Press and hold the device for activation to the FORWARD position. While you hold the device for activation, verify that the setting is correct. If the value of the setting is not correct, repeat Step 8 through Step 10.
When the value is within the specification, press the OK key (8) .
Illustration 13 g02208429
After the OK key is pressed, the monitor will automatically continue with the tuning of the next pressure value. Hold the attachment controls in the FORWARD position. Press the OK key (8) .
Illustration 14 g02208430
Press the right key (2) in order to increase the value. Press the left key (5) in order to decrease the value. Adjust the value until the gauge pressure is within the specification.
Press the device for activation 3 times and release the device for activation 3 times.Note: Pressing the device for activation three times ensures that an accurate reading will result.
Press and hold the device for activation to the FORWARD position. While you hold the device for activation, verify that the setting is correct. If the value of the setting is not correct, repeat Step 13 through Step 15.
When the value is within the specification, press the OK key (8) .
Illustration 15 g02208431
Illustration 16 g02208432
Release all controls. When all controls are in the neutral position, press the OK key (8) .
Illustration 17 g02208433
The calibration is complete. Press the cancel key (7) in order to exit the process of calibration.
Illustration 18 g02208434
The "ERROR ID"
Parts lock Caterpillar catalog:
5449578
LOCK
Caterpillar
Caterpillar
5449246
LOCK
Caterpillar
Caterpillar
5449218
LOCK
Caterpillar
Caterpillar
5449191
LOCK
Caterpillar
Caterpillar
5448986
LOCK
Caterpillar
Caterpillar
5448728
LOCK
Caterpillar
Caterpillar
5460905
LOCK-BREAKER
Caterpillar
Caterpillar
5453467
LOCK
Caterpillar
Caterpillar
5453078
LOCK
Caterpillar
Caterpillar
5452212
LOCK
Caterpillar
Caterpillar
5451606
LOCK
Caterpillar
Caterpillar
5451484
LOCK
Caterpillar
Caterpillar