0000003 LOCKNUT Caterpillar parts
D6M, E120
Rating:
Alternative (cross code) number:
CA0000003
000-0003
0000003
CA0000003
000-0003
0000003
EXCAVATOR, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$13.45
28 May 2018
Sylvania: Sylvania
5 x 6" 4w T5 Fluorescent Tube Cool White [4000k] (SLI 0000003)
4W T5 Halophosphor Mini Tube, Cool White, 150mm || halophosphate coating to give a standard performance || B class energy efficiency rating || average life of 5,000 hours || all items expertly packaged with care
4W T5 Halophosphor Mini Tube, Cool White, 150mm || halophosphate coating to give a standard performance || B class energy efficiency rating || average life of 5,000 hours || all items expertly packaged with care
11 Jan 2018
Sylvania: Sylvania
30 x 6" 4w T5 Fluorescent Tube Cool White [4000k] (SLI 0000003)
4W T5 Halophosphor Mini Tube, Cool White, 150mm||halophosphate coating to give a standard performance||B class energy efficiency rating||average life of 5,000 hours||all items expertly packaged with care
4W T5 Halophosphor Mini Tube, Cool White, 150mm||halophosphate coating to give a standard performance||B class energy efficiency rating||average life of 5,000 hours||all items expertly packaged with care
$8.94
28 May 2018
Sylvania: Sylvania
2 x 6" 4w T5 Fluorescent Tube Cool White [4000k] (SLI 0000003)
4W T5 Halophosphor Mini Tube, Cool White, 150mm || halophosphate coating to give a standard performance || B class energy efficiency rating || average life of 5,000 hours || all items expertly packaged with care
4W T5 Halophosphor Mini Tube, Cool White, 150mm || halophosphate coating to give a standard performance || B class energy efficiency rating || average life of 5,000 hours || all items expertly packaged with care
Information:
Illustration 1 g02623458
Schematic for the Pilot Pressure Solenoid ValveThis solenoid is connected to the Implement ECM. The Implement ECM sends the diagnostic information to the Machine ECM via the CAN data link. This diagnostic code is recorded when the Implement ECM detects an incomplete electrical path. The electrical path from the Implement ECM to the solenoid back to the Implement ECM is incomplete.The possible causes for this diagnostic code are listed:
The signal circuit from the Implement ECM to the solenoids is open.
The return circuit from the solenoid is open.
The internal windings for the solenoid have high impedance.
The internal windings for the solenoid are open.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and that all connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position.
Disconnect the solenoid with the diagnostic code from the harness.
Observe the ON/OFF status of the diagnostic code indicator.
At the harness connector for the solenoid, place a jumper wire between contact 1 (wire E918-GN) and contact 2 (wire H708-OR).Expected Result:The diagnostic code remains active.Results:
YES - The diagnostic code remains active. The harness has failed or the Implement ECM has failed. Proceed to Test Step 2.
NO - The diagnostic code is inactive.Repair: The solenoid valve has failed. Repeat this test in order to verify the failure. Repair the solenoid or replace the solenoid. Repair the connecting harness or replace the connecting harness at the solenoid.STOPTest Step 2. CHECK THE HARNESS.
Turn the disconnect switch to the OFF position.
Remove the jumper wire from contact 1to 2.
Reconnect the solenoid valve to the harness.
Disconnect the harness from the Implement ECM.
At the harness connector for the Implement ECM, measure the resistance between contact 4 (wire H708-OR) and contact 2 (wire E918-GN).Expected Result:The resistance is greater than 5000 Ohms (no continuity).Results:
YES - The resistance is greater than 5000 Ohms (no continuity).Repair: The harness circuit has failed. Wire H708-OR is open in the harness between the Implement ECM and the solenoid valve, or the wire E918-GN to the solenoid valve is open. Repair the harness or replace the harness.STOP
NO - The resistance is less than 5000 Ohms.Repair: Check the circuit again.If the cause of the problem is not found, contact the Technical Communicator for your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the Implement ECM requires replacement, see Troubleshooting, "Electronic Control Module (ECM) - Replace".STOP
Caterpillar parts catalog:
Parts locknut Caterpillar catalog:
6T9069
LOCKNUT
D5B, D6D
D5B, D6D
1K8872
LOCKNUT
955K, 977D, 977H, D9L
955K, 977D, 977H, D9L
2S6235
LOCKNUT
D5C III
D5C III
3171117
LOCKNUT
120K, 120K 2, 657E, D6T LGP, D6T LGPPAT, D7E, D7E LGP, R1600H
120K, 120K 2, 657E, D6T LGP, D6T LGPPAT, D7E, D7E LGP, R1600H
4562605
LOCKNUT
D6R STD
D6R STD
4J8734
LOCKNUT
641, 641B, 651, 651B, 651E, 657, 657B, 657E, 657G, 666, 973D, 988B, 988F, 988F II, 992, D10N, D10R, D10T, D10T2, D9L, R1700 II, R1700G, R2900, R2900G
641, 641B, 651, 651B, 651E, 657, 657B, 657E, 657G, 666, 973D, 988B, 988F, 988F II, 992, D10N, D10R, D10T, D10T2, D9L, R1700 II, R1700G, R2900, R2900G
3D4904
LOCKNUT
120B, 120G, 120H, 120H ES, 120H NA, 120M, 120M 2, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12M 2, 12M 3 AWD, 130G, 135H, 135H NA, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140M, 140M 2, 140M 3 AWD, 143H, 1...
120B, 120G, 120H, 120H ES, 120H NA, 120M, 120M 2, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12M 2, 12M 3 AWD, 130G, 135H, 135H NA, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140M, 140M 2, 140M 3 AWD, 143H, 1...
9C8287
LOCKNUT-STAKE
2470C, 2570C, 2670C, 2864C, 515, 518C, 525, 525B, 525C, 525D, 533, 535B, 535C, 535D, 543, 545, 545C, 545D, 553C, 555D, 563C, 573C, 586C, 936F, 938F, 938G, 938G II, 950F, 950F II, 950G, 950G II, 950H, ...
2470C, 2570C, 2670C, 2864C, 515, 518C, 525, 525B, 525C, 525D, 533, 535B, 535C, 535D, 543, 545, 545C, 545D, 553C, 555D, 563C, 573C, 586C, 936F, 938F, 938G, 938G II, 950F, 950F II, 950G, 950G II, 950H, ...
3I4155
LOCKNUT
D7H
D7H
1421288
LOCKNUT
D6R III
D6R III
9T0389
LOCKNUT
950G II, 966H, D6R III
950G II, 966H, D6R III
2K49873
LOCKNUT
D6G
D6G