1644096 MANIFOLD-INLET Caterpillar parts
3054, 312B L, 312C, 908, AP-800C, BG-225B, CB-534C, CB-535B, CP-433C, CP-433E, CS-431C, CS-433C, PF-290B, PS-200B, PS-300B, PS-360B, TH103, TH350B, TH355B, TH460B, TH62, TH63, TH82, TH83
Rating:
Alternative (cross code) number:
CA1644096
164-4096
1644096
CA1644096
164-4096
1644096
Weight: 4 pounds 2 kg.
ASPHALT PAVER, VIBRATORY COMPACTOR,
Compatible equipment models: 1644096:
Information:
High Idle Speed
The "High Idle Speed" is the maximum engine rpm.
Table 3
Minimum Maximum Default
1900 rpm 2900 rpm 2205 rpm ECM Identification Parameter
Equipment ID
"Equipment ID" is the identification of the equipment that is assigned by the customer. The "Equipment ID" is only for reference only by the customer. The "Equipment ID" is not required by the Electronic Control Module (ECM).
Table 4
Value Default
17 digits
The available characters are dependent on the service tool that is being used. Not programmed Miscellaneous
Monitoring Mode Shutdowns
"Monitoring Mode Shutdowns" controls the shutdown feature that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-3" suffix is detected, the engine will be shut down.
Table 5
Value Default
Disabled
Enabled Disabled Monitoring Mode Derates
"Monitoring Mode Derates" controls the derate that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-2" is detected, the engine will be derated.
Table 6
Value Default
Disabled
Enabled Enabled Limp Home Desired Engine Speed
The "Limp Home Desired Engine Speed" is the maximum speed of the engine when the engine has been derated.
Table 7
Minimum Maximum Default
700 rpm 1800 rpm 1200 rpm J1939 Continuous Fault Handling
Remote Torque Speed Control Enable Status
The "Remote Torque Speed Control Enable Status" parameter determines the way that faults will be handled by the ECM when the "J1939 Torque Speed Control (TSC1)" message is used as a speed request input to the ECM. Programming the "Remote Torque Speed Control Enable Status" to "Enabled" will cause the ECM to display a fault code if a valid TSC1 message is not received by the engine ECM within 30 seconds of the engine starting. If the" Remote Torque Speed Control Enable Status" is programmed to "Disabled", the engine will display a 247-12 Data Link Malfunction immediately after a loss of a TSC1 message. Program "Remote Torque Speed Control Enable Status" to "Enabled" if the ECM will always be receiving a TSC1 message.
Table 8
Value Default
Disabled
Enabled Enabled Configurable Inputs
Air Filter Restriction Switch Installation Status
An "Air Filter Restriction Switch" is an optional switch input. Programming the "Air Filter Restriction Switch Installation Status" parameter to "Enabled" notifies the ECM that an input from the air filter restriction switch is present on pin J1:47. When this parameter is programmed to "Enabled" and the air filter restriction switch closes, an E172-1 or J107-15 event code will be displayed.
Table 9
Value Default
Installed
Not Installed Installed Fuel/Water Separator Switch Installation Status
A fuel/water separator switch is an optional switch input. Programming the "Fuel/Water Separator Switch Installation Status" parameter to "Enabled" notifies the ECM that a fuel/water separator switch input is present on pin J1:44. When this parameter is programmed to "Enabled" and the fuel/water separator switch closes, a warning light on the control panel will be illuminated.
Table 10
Value Default
Installed
Not Installed Installed (420E)
Not Installed (450E) User Defined Switch Installation Status
A user defined switch is not installed on this application.
Table 11
Value Default
Installed
Not Installed Not Installed
The "High Idle Speed" is the maximum engine rpm.
Table 3
Minimum Maximum Default
1900 rpm 2900 rpm 2205 rpm ECM Identification Parameter
Equipment ID
"Equipment ID" is the identification of the equipment that is assigned by the customer. The "Equipment ID" is only for reference only by the customer. The "Equipment ID" is not required by the Electronic Control Module (ECM).
Table 4
Value Default
17 digits
The available characters are dependent on the service tool that is being used. Not programmed Miscellaneous
Monitoring Mode Shutdowns
"Monitoring Mode Shutdowns" controls the shutdown feature that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-3" suffix is detected, the engine will be shut down.
Table 5
Value Default
Disabled
Enabled Disabled Monitoring Mode Derates
"Monitoring Mode Derates" controls the derate that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-2" is detected, the engine will be derated.
Table 6
Value Default
Disabled
Enabled Enabled Limp Home Desired Engine Speed
The "Limp Home Desired Engine Speed" is the maximum speed of the engine when the engine has been derated.
Table 7
Minimum Maximum Default
700 rpm 1800 rpm 1200 rpm J1939 Continuous Fault Handling
Remote Torque Speed Control Enable Status
The "Remote Torque Speed Control Enable Status" parameter determines the way that faults will be handled by the ECM when the "J1939 Torque Speed Control (TSC1)" message is used as a speed request input to the ECM. Programming the "Remote Torque Speed Control Enable Status" to "Enabled" will cause the ECM to display a fault code if a valid TSC1 message is not received by the engine ECM within 30 seconds of the engine starting. If the" Remote Torque Speed Control Enable Status" is programmed to "Disabled", the engine will display a 247-12 Data Link Malfunction immediately after a loss of a TSC1 message. Program "Remote Torque Speed Control Enable Status" to "Enabled" if the ECM will always be receiving a TSC1 message.
Table 8
Value Default
Disabled
Enabled Enabled Configurable Inputs
Air Filter Restriction Switch Installation Status
An "Air Filter Restriction Switch" is an optional switch input. Programming the "Air Filter Restriction Switch Installation Status" parameter to "Enabled" notifies the ECM that an input from the air filter restriction switch is present on pin J1:47. When this parameter is programmed to "Enabled" and the air filter restriction switch closes, an E172-1 or J107-15 event code will be displayed.
Table 9
Value Default
Installed
Not Installed Installed Fuel/Water Separator Switch Installation Status
A fuel/water separator switch is an optional switch input. Programming the "Fuel/Water Separator Switch Installation Status" parameter to "Enabled" notifies the ECM that a fuel/water separator switch input is present on pin J1:44. When this parameter is programmed to "Enabled" and the fuel/water separator switch closes, a warning light on the control panel will be illuminated.
Table 10
Value Default
Installed
Not Installed Installed (420E)
Not Installed (450E) User Defined Switch Installation Status
A user defined switch is not installed on this application.
Table 11
Value Default
Installed
Not Installed Not Installed
Cat SIS web machinery list:
Parts manifold Caterpillar catalog:
1970198
MANIFOLD GP-CONTROL
312C, 315C, 318C, 319C, 320C, 322C, 322C FM, 325C, 325C FM, 330C FM, 330C L, 330C MH
312C, 315C, 318C, 319C, 320C, 322C, 322C FM, 325C, 325C FM, 330C FM, 330C L, 330C MH
1467815
MANIFOLD
902, 906, 908
902, 906, 908
1785158
MANIFOLD
902, 906, 908
902, 906, 908
1089451
MANIFOLD-ENGINE SENSOR
AP-1000B, AP-1055B, AP-800C, AP-900B, BG-225B, BG-225C, BG-2455C, BG-245C
AP-1000B, AP-1055B, AP-800C, AP-900B, BG-225B, BG-225C, BG-2455C, BG-245C
1151160
MANIFOLD-INLET
CB-434B, CB-434C, CB-544, CB-545, CP-433C, CS-323C, CS-431C
CB-434B, CB-434C, CB-544, CB-545, CP-433C, CS-323C, CS-431C
1178299
MANIFOLD
CP-433C, CS-431C, CS-531, CS-531C
CP-433C, CS-431C, CS-531, CS-531C
1199303
MANIFOLD
CS-431C, CS-531, CS-531C, CS-533C, CS-563C
CS-431C, CS-531, CS-531C, CS-533C, CS-563C
1555427
MANIFOLD
PS-150B, PS-150C, PS-200B, PS-360B
PS-150B, PS-150C, PS-200B, PS-360B
1555423
MANIFOLD
PS-150B, PS-150C, PS-200B, PS-360B
PS-150B, PS-150C, PS-200B, PS-360B
1229811
MANIFOLD
CW-14, PS-150B, PS-150C, PS-200B
CW-14, PS-150B, PS-150C, PS-200B
1883085
MANIFOLD-AIR INLET
PF-290B, PS-360B
PF-290B, PS-360B
1317705
MANIFOLD-INLET
3054, AP-800C, BG-225B, CB-534B, CB-534C, CB-535B, CP-433C, CS-431C, PS-200B, PS-300B, TH103, TH62, TH63, TH82, TH83
3054, AP-800C, BG-225B, CB-534B, CB-534C, CB-535B, CP-433C, CS-431C, PS-200B, PS-300B, TH103, TH62, TH63, TH82, TH83
6I4007
MANIFOLD-EXHAUST
3054, CB-434B, CB-434C, CP-433C, CS-323C, CS-431C, PS-150B, TH62, TH63, TH82
3054, CB-434B, CB-434C, CP-433C, CS-323C, CS-431C, PS-150B, TH62, TH63, TH82
1003164
MANIFOLD-EXHAUST
3054, AP-800C, BG-225B, CB-534B, CB-534C, CB-535B, CP-433C, CS-431C, PS-200B, PS-300B, TH103, TH62, TH63, TH82, TH83
3054, AP-800C, BG-225B, CB-534B, CB-534C, CB-535B, CP-433C, CS-431C, PS-200B, PS-300B, TH103, TH62, TH63, TH82, TH83
7T3062
MANIFOLD-CLUTCH
65, 65C, 65E, 75C, 75D, 75E, 85C, 85D, 85E, 95E
65, 65C, 65E, 75C, 75D, 75E, 85C, 85D, 85E, 95E
6E1898
MANIFOLD
65C, 65E, 75C, 75D, 75E, 85C, 85D, 85E, 95E
65C, 65E, 75C, 75D, 75E, 85C, 85D, 85E, 95E
6Y1280
MANIFOLD
65, 65C, 65E, 75C, 75D, 75E, 85C, 85D, 85E, 95E
65, 65C, 65E, 75C, 75D, 75E, 85C, 85D, 85E, 95E
1487129
MANIFOLD-INLET
416C, 426C, 428C, 436C, 438C
416C, 426C, 428C, 436C, 438C
1503374
MANIFOLD
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 561N, D5N, D6N
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 561N, D5N, D6N
1274405
MANIFOLD
416C, 426C, 428B, 428C, 436C, 438C, 938H, IT38H
416C, 426C, 428B, 428C, 436C, 438C, 938H, IT38H
1219442
MANIFOLD
428B
428B
1188628
MANIFOLD BLOCK
TH103, TH62, TH63, TH82, TH83
TH103, TH62, TH63, TH82, TH83
1445383
MANIFOLD-EXHAUST
3054, AP-800C, BG-225B, CB-534C, CB-535B, CP-433C, CP-433E, CS-431C, CS-433C, PF-290B, PS-200B, PS-300B, PS-360B, TH103, TH350B, TH355B, TH460B, TH62, TH63, TH82, TH83
3054, AP-800C, BG-225B, CB-534C, CB-535B, CP-433C, CP-433E, CS-431C, CS-433C, PF-290B, PS-200B, PS-300B, PS-360B, TH103, TH350B, TH355B, TH460B, TH62, TH63, TH82, TH83