AVSPARE.COM
parts catalog

MANIFOLD GP-CONTROL 1911390 - Caterpillar


1911390 MANIFOLD GP-CONTROL Caterpillar parts 304, 305, 305.5, 306
Rating:
84
Alternative (cross code) number:
CA1911390
191-1390
1911390
Caterpillar 1911390 MANIFOLD GP-CONTROL
Weight: 3 pounds 1 kg.

Buy MANIFOLD GP-CONTROL 1911390 Caterpillar genuine, new aftermarket tractor parts with delivery
MINI HYD EXCAVATOR,

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$1,509.55

06 Aug 2025

US: YEM PARTS
YANNAL PART 191-1390 274-4199 Control Manifold Suitable for Caterpillar Engine Part 304
YANNAL PART Product Name: Control Manifold || Product Name: 191-1390 274-4199 || Application: Compatible for Caterpillar 304 || Warranty: 1 Year || Note: Please verify your part number before ordering, any problem please feel free to contact us, thanks.
$1,509.55

24 Jul 2025

US: YEM PARTS
YANNAL PART Control Manifold 191-1390 274-4199 Suitable for Caterpillar Engine Part 305.5
YANNAL PART Product Name: Control Manifold || Product Name: 191-1390 274-4199 || Application: Compatible for Caterpillar 305.5 || Warranty: 1 Year || Note: Please verify your part number before ordering, any problem please feel free to contact us, thanks.
$1,643.04

14 Jun 2025

US: YEM PARTS
YANNAL PART 191-1390 274-4199 Control Manifold Suitable for Caterpillar Engine Part 304
YANNAL PART Product Name: Control Manifold || Product Name: 191-1390 274-4199 || Application: Compatible for Caterpillar 304 || Warranty: 1 Year || Note: Please verify your part number before ordering, any problem please feel free to contact us, thanks.
Number on catalog scheme: 33
  For full view, you need register

Compatible equipment models: 1911390:

MINI HYD EXCAVATOR  304   305   305.5   306   Caterpillar

Information:

If the current rises above the "Generator Reverse Power Percentage Threshold" setpoint value, then the reverse power timer will begin timing. When the timer expires, the generator reverse power event is made active (if the current has been above the threshold level continuously while timing). If the current drops below the generator reverse power percentage threshold, then the generator reverse power event will be made inactive and the timer will be reset. If a reverse power condition is detected, "GEN REVERSE POWER SHUTDOWN" or "GEN REVERSE POWER " will be displayed on the EMCP 4 in order to inform the operator of a reverse power condition.Note: The severity of the reverse power condition will determine if a warning or shutdown event occurs.Conditions Which Generate This Code:The code for generator reverse power is generated when the EMCP 4 determines that a generator reverse power condition has occurred. Test Step 1. TALK TO THE OPERATOR
Determine the conditions that caused the reverse power condition. Expected Result:A reverse power was caused by an occurrence known to the operator. The operator would like to put the genset back into service.Results:
OK - The operator can determine the cause for the reverse power condition, the condition has been repaired, and the operator wants to put the genset back into service.Repair: Reset the genset. Resume normal operation and verify that the problem has been corrected.STOP
NOT OK - The reverse power condition was not caused by an occurrence known to the operator. Proceed to Test Step 3Test Step 2. CHECK THE MEASURED VALUES
Check the displayed values on the controller for the following:
Voltage
Current
Power Expected Result:The generator set parameters are within ratings and the expected values.Results:
YES - The values are within ratings and the expected values. Proceed to Test Step 3.
NO - The values are NOT within ratings and the expected values.Repair: Check the sensing wiring.STOPTest Step 3. CHECK THE SETPOINTS
View the "Generator Reverse Power" setpoints. Make a note of the setpoints. See Testing and Adjusting, "Electronic Control Module (Generator Set) - Configure". Compare the setpoints against the default setpoints of the particular generator set. Expected Result:The setpoints are correct.Results:
OK - The setpoints are correct for your particular genset. Proceed to Test Step 4.
NOT OK - The setpoints are NOT correct.Repair: Reprogram the setpoints. Reset the genset. Resume normal operation and verify that the problem has been corrected.STOPTest Step 4. CHECK THE POLARITY OF THE CURRENT TRANSFORMERS
Illustration 1 g00607036
(A) Current Transformer Polarity Dot
Press the STOP key in order to shut down the engine.
Check the polarity of the current transformers. The polarity dots on all of the transformers should be towards the genset. Both the primary and secondary of the CT's must be checked. Refer to Illustration 1. Expected Result:The polarity of the current transformers should be correct.Results:
OK - The polarity of the current transformers is correct.Repair: It is unlikely that the EMCP 4 has failed. Exit this procedure and perform this procedure again. If the diagnostic code is still present, then replace the EMCP 4. Refer to Testing and

Caterpillar parts catalog:

Caterpillar parts catalog
305CR Mini Hydraulic Excavator DSA00001-UP (MACHINE) POWERED BY K4N Engine
304CR Mini Hydraulic Excavator NAD00001-UP (MACHINE) POWERED BY S4L2 Engine
305CR Mini Hydraulic Excavator DGT00001-UP (MACHINE) POWERED BY K4N Engine
305.5 Mini Hydraulic Excavator DCK00001-UP (MACHINE) POWERED BY 4M40 Engine
305.5 Mini Hydraulic Excavator CXZ00001-UP (MACHINE) POWERED BY 4M40 Engine
306 Mini Hydraulic Excavator MXH00001-UP (MACHINE) POWERED BY 4M40 Engine


Parts manifold Caterpillar catalog:

1537770 MANIFOLD
302.5, 303.5, 304, 304.5, 305, 305.5, 305.5E, 306, 306E
1397851 MANIFOLD GP-EXHAUST
305.5, 306, 307B, 307C, 307D, 308C
1397922 MANIFOLD
305.5, 306, 307B, 307C, 307D, 308C
2128552 MANIFOLD GP-EXHAUST
320C, 320C FM, 320C L, 320D, 320D LRR, 321C, 323D L, 323D LN
3639783 MANIFOLD GP-CONTROL
420F, 428F, 430F, 432F, 444F
2582801 MANIFOLD & SOLENOID GP-CONTROL
246C, 256C, 277C, 277C2, 279C, 279C2
3430584 MANIFOLD GP-EXHAUST
12M 2, 12M 3, 12M 3 AWD, 140M 2, 140M 3, 140M 3 AWD, 160M 2, 160M 3, 160M 3 AWD
6I3952 MANIFOLD GP-EXHAUST
3406B, 3406C, 3406E, C-15, C-16, C16
2922033 MANIFOLD GP-VALVE
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M
1151567 MANIFOLD GP-INLET
CB-434B, CB-434C, CB-544, CB-545
7W8582 MANIFOLD GP-EXHAUST
3306, 3306B, 611, 615C, 65
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.