1P2167 MANIFOLD ASSEM. Caterpillar parts
518C, 528B, 530B, 54, 55, D4E, D5B, D6D, D7G, D9H
Rating:
Alternative (cross code) number:
CA1P2167
1P-2167
1P2167
CA1P2167
1P-2167
1P2167
Weight: 5 pounds 2 kg.
TRACK-TYPE TRACTOR, WINCH,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
This part in 2 request:
Show.
This information for suppliers only!
2023-03-03
2023-03-01
Compatible equipment models: 1P2167:
Information:
Initial Start-Up
1. Remove the left side access panel of the generator.2. Loosen the locknuts on the voltage droop, voltage level, and voltage gain controls.3. Turn the voltage droop control (1) counterclockwise to zero droop and tighten the locknut.
VOLTAGE ADJUSTMENT CONTROLS (SR4 Generator Shown)
1. Voltage Droop 2. Voltage Level 3. Voltage Gain 4. Circuit Breaker (SR4 Generator Only)4. Turn the gain control (3) counterclockwise to zero, then turn the gain control to about 1/4 of full range of clockwise travel.5. Perform required maintenance on engine before starting.6. Start the engine and allow it to warm.7. Increase engine speed to full governed speed (high idle).8. Observe the voltmeter reading. If desired voltage is not indicated, set no load voltage with voltage level control (2).9. Close the load circuit breaker and apply full load gradually. Adjust governor control until nameplate frequency is on the Hertz meter.10. a. If voltmeter reading increases with full load applied, turn gain control (3) slightly in counterclockwise direction.b. If voltmeter reading decreases with full load applied, turn gain control (3) slightly in clockwise direction.11. Remove load, adjust voltage level control (2) if necessary to obtain desired voltage.12. Apply the load, observe voltmeter reading. Repeat steps 9 thru 12 until no load voltage equals full load voltage.13. Tighten the locknuts on all controls and install the access panel of the generator.14. Circuit breaker (4) will open if excessive field current should occur. Push to reset the circuit breaker. If breaker opens again, contact your Caterpillar dealer.Starting
1. Make all preliminary engine starting checks.2. Be sure the main or line circuit breaker is open.3. Start the engine and allow it to warm up.4. Adjust to full load RPM.5. Close the main circuit breaker.6. Apply the load. Do not try to apply full load in one move, rather apply the load in increments to maintain system frequency at a constant level.7. Readjust governor for rated frequency.Stopping
1. Remove the load in increments.2. Open the circuit breaker.3. Allow the engine to run for 5 minutes to cool.4. Stop the engine.
1. Remove the left side access panel of the generator.2. Loosen the locknuts on the voltage droop, voltage level, and voltage gain controls.3. Turn the voltage droop control (1) counterclockwise to zero droop and tighten the locknut.
VOLTAGE ADJUSTMENT CONTROLS (SR4 Generator Shown)
1. Voltage Droop 2. Voltage Level 3. Voltage Gain 4. Circuit Breaker (SR4 Generator Only)4. Turn the gain control (3) counterclockwise to zero, then turn the gain control to about 1/4 of full range of clockwise travel.5. Perform required maintenance on engine before starting.6. Start the engine and allow it to warm.7. Increase engine speed to full governed speed (high idle).8. Observe the voltmeter reading. If desired voltage is not indicated, set no load voltage with voltage level control (2).9. Close the load circuit breaker and apply full load gradually. Adjust governor control until nameplate frequency is on the Hertz meter.10. a. If voltmeter reading increases with full load applied, turn gain control (3) slightly in counterclockwise direction.b. If voltmeter reading decreases with full load applied, turn gain control (3) slightly in clockwise direction.11. Remove load, adjust voltage level control (2) if necessary to obtain desired voltage.12. Apply the load, observe voltmeter reading. Repeat steps 9 thru 12 until no load voltage equals full load voltage.13. Tighten the locknuts on all controls and install the access panel of the generator.14. Circuit breaker (4) will open if excessive field current should occur. Push to reset the circuit breaker. If breaker opens again, contact your Caterpillar dealer.Starting
1. Make all preliminary engine starting checks.2. Be sure the main or line circuit breaker is open.3. Start the engine and allow it to warm up.4. Adjust to full load RPM.5. Close the main circuit breaker.6. Apply the load. Do not try to apply full load in one move, rather apply the load in increments to maintain system frequency at a constant level.7. Readjust governor for rated frequency.Stopping
1. Remove the load in increments.2. Open the circuit breaker.3. Allow the engine to run for 5 minutes to cool.4. Stop the engine.
Caterpillar parts catalog:
Parts manifold Caterpillar catalog:
2P6571
MANIFOLD GP-EXHAUST
120G, 130G, 215, 215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 3304, 3304B, 518, 518C, 527, 930, 930R, 936, 936F, 950, 950B, 950B/950E, 955K, 955L, CS-643, D4D, D4E, D4E SR, D4H, D4H XL, D4HTSK III, D...
120G, 130G, 215, 215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 3304, 3304B, 518, 518C, 527, 930, 930R, 936, 936F, 950, 950B, 950B/950E, 955K, 955L, CS-643, D4D, D4E, D4E SR, D4H, D4H XL, D4HTSK III, D...
9S2355
MANIFOLD-EXHAUST
12F, 12G, 12H, 12H NA, 140G, 140H, 143H, 160H, 3306, 561C, D5, D5B, D5E, D6C
12F, 12G, 12H, 12H NA, 140G, 140H, 143H, 160H, 3306, 561C, D5, D5B, D5E, D6C
7N3486
MANIFOLD-EXHAUST
12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 3306, 3306B, 528B, 530B, 966C, D5B, D6C, D6D, D6E, D6E SR, D6G SR, D6H, D6H XL, D6H XR, D6R
12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 3306, 3306B, 528B, 530B, 966C, D5B, D6C, D6D, D6E, D6E SR, D6G SR, D6H, D6H XL, D6H XR, D6R
1P1216
MANIFOLD-EXHAUST
120G, 130G, 3304, 3304B, 518, 518C, 527, 936F, 955K, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5HTSK II, G936
120G, 130G, 3304, 3304B, 518, 518C, 527, 936F, 955K, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5HTSK II, G936
3P6812
MANIFOLD AS-PUMP
D6C, D6D, D6E, D6E SR, D6G, D6G2 LGP, D6G2 XL
D6C, D6D, D6E, D6E SR, D6G, D6G2 LGP, D6G2 XL
3P0366
MANIFOLD ASSEM.
572G, D7G, D7G2, D8H, D8K, D9H
572G, D7G, D7G2, D8H, D8K, D9H
3P4863
MANIFOLD ASSEM.
571G, 572G, D7F, D7G, D7G2
571G, 572G, D7F, D7G, D7G2
5N8921
MANIFOLD
D9H
D9H
5N8879
MANIFOLD
D9H
D9H
3P0364
MANIFOLD ASSEM.
572G, D7G, D7G2
572G, D7G, D7G2
9S7840
MANIFOLD AS
7A, D7G, D7G2
7A, D7G, D7G2
3P4832
MANIFOLD
173B, D7G
173B, D7G
9S9892
MANIFOLD
D8H, D9G
D8H, D9G
5J3136
MANIFOLD
173B, 183B
173B, 183B
9M0761
MANIFOLD
D6C
D6C
2M3437
MANIFOLD ASSEM.
D7F, D8H
D7F, D8H
4N0085
MANIFOLD
943
943
3S6795
MANIFOLD
561C, D5
561C, D5
8S3505
MANIFOLD ASSEM.
941, 951B, D4D
941, 951B, D4D
7S6877
MANIFOLD ASSEM.
955K, 955L
955K, 955L
2P4403
MANIFOLD ASSEM.
941, 951B, D4D
941, 951B, D4D