2542662 MANIFOLD & VALVE GP Caterpillar parts
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH
Rating:
Alternative (cross code) number:
CA2542662
254-2662
2542662
CA2542662
254-2662
2542662
Weight: 21 pounds 9 kg.
WHEELED EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 2542662:
Information:
The current requirement for both the 12V Heater and 24V Heater is the same at 90 to 100 amperes. Do not use wire that is smaller than #4. The 24V Heater produces approximately 2000 Watts heat output; the 12V Heater produces approximately 1000 Watts.Installation Tips
*Power wire (cable) to heater must have extra length to allow for engine movement in the soft engine mounts. Wiring must not rub. Use rubber insulated clips to secure wires.*Terminals for power cables should be soldered, in addition to crimped.*Power wire from Battery POS (+) connection for machines with "main disconnect" switch must be on the "switched "side of the main disconnect switch, so that the battery power to the heater relay is off whenever the main disconnect switch is off. This can be accomplished by connecting power wire (cable) to the same location as either end of the POS starter cable, at the disconnect switch or at the starter.*Be certain inlet manifold cover, air inlet elbow, gaskets, and hoses are assembled securely to avoid possibility of dirt entry.*It may be necessary to loosen the turbocharger compressor housing and rotate the housing slightly to align the housing with the new air inlet elbow. It is NOT necessary to remove the turbocharger from the engine. Be sure to re-tighten the turbocharger compressor housing.*Use rubber boots to insulate all wiring connections to avoid short circuits.*Be sure to use heater assembly, relay, and indicator lamp of correct voltage.*Pushbutton switch to control relay should be wired so that power is only available to the pushbutton switch when the ignition keyswitch is "ON". AIH System should not be able to turn on AIH when key switch used for starting is "OFF".*Indicator lamp should be located in or near instrument panel so that operator can see it easily while holding pushbutton for preheat. Indicator lamp should be labeled, such as "Air Heater" or "Inlet Heater", and should have appropriate instructions, such as "For cold weather use. Do not exceed 30 seconds preheat before cranking engine ". Indicator lamp should be wired in parallel with the heater relay (not in series), so that pushbutton activates the indicator lamp in parallel with the heater relay. If preferred, the indicator lamp can be wired to the switched side of the power relay, so that indicator lamp will work only if power relay is functional and provides power to the heater. This would require a wire from the switched side of the relay to the indicator lamp at the instrument panel.*If equipped with either starting aid. The AIH System may be used with an ether injection system only if the ether is injected directly into the inlet manifold, so that the ether does not flow across the heater element. Do not use ether that is manually sprayed into the air system from a spray can when using the AIH System, as this ether would have to flow over the hot AIH element. If an existing Ether Aid is plumbed into the air cleaner
*Power wire (cable) to heater must have extra length to allow for engine movement in the soft engine mounts. Wiring must not rub. Use rubber insulated clips to secure wires.*Terminals for power cables should be soldered, in addition to crimped.*Power wire from Battery POS (+) connection for machines with "main disconnect" switch must be on the "switched "side of the main disconnect switch, so that the battery power to the heater relay is off whenever the main disconnect switch is off. This can be accomplished by connecting power wire (cable) to the same location as either end of the POS starter cable, at the disconnect switch or at the starter.*Be certain inlet manifold cover, air inlet elbow, gaskets, and hoses are assembled securely to avoid possibility of dirt entry.*It may be necessary to loosen the turbocharger compressor housing and rotate the housing slightly to align the housing with the new air inlet elbow. It is NOT necessary to remove the turbocharger from the engine. Be sure to re-tighten the turbocharger compressor housing.*Use rubber boots to insulate all wiring connections to avoid short circuits.*Be sure to use heater assembly, relay, and indicator lamp of correct voltage.*Pushbutton switch to control relay should be wired so that power is only available to the pushbutton switch when the ignition keyswitch is "ON". AIH System should not be able to turn on AIH when key switch used for starting is "OFF".*Indicator lamp should be located in or near instrument panel so that operator can see it easily while holding pushbutton for preheat. Indicator lamp should be labeled, such as "Air Heater" or "Inlet Heater", and should have appropriate instructions, such as "For cold weather use. Do not exceed 30 seconds preheat before cranking engine ". Indicator lamp should be wired in parallel with the heater relay (not in series), so that pushbutton activates the indicator lamp in parallel with the heater relay. If preferred, the indicator lamp can be wired to the switched side of the power relay, so that indicator lamp will work only if power relay is functional and provides power to the heater. This would require a wire from the switched side of the relay to the indicator lamp at the instrument panel.*If equipped with either starting aid. The AIH System may be used with an ether injection system only if the ether is injected directly into the inlet manifold, so that the ether does not flow across the heater element. Do not use ether that is manually sprayed into the air system from a spray can when using the AIH System, as this ether would have to flow over the hot AIH element. If an existing Ether Aid is plumbed into the air cleaner
Caterpillar SIS machinery equipment:
Caterpillar SIS
M316D Excavator W6A00001-UP (MACHINE) POWERED BY C6.6 Engine »
254-2662
MANIFOLD & VALVE GP
M318D Excavator W8P00001-UP (MACHINE) POWERED BY C6.6 Engine »
254-2662
MANIFOLD & VALVE GP
M318D Material Handler W8R00001-UP (MACHINE) POWERED BY C6.6 Engine »
254-2662
MANIFOLD & VALVE GP
M322D Excavator W2S00001-UP (MACHINE) POWERED BY C6.6 Engine »
254-2662
MANIFOLD & VALVE GP
M322D Material Handler W2T00001-UP (MACHINE) POWERED BY C6.6 Engine »
254-2662
MANIFOLD & VALVE GP
M313D Excavator W3H00001-UP (MACHINE) POWERED BY C4.4 Engine »
254-2662
MANIFOLD & VALVE GP
M315D Excavator W5M00001-UP (MACHINE) POWERED BY C4.4 Engine »
254-2662
MANIFOLD & VALVE GP
Caterpillar parts catalog:
Parts manifold Caterpillar catalog:
3068858
MANIFOLD & VALVE GP
M313D, M315D, M316D, M318D, M322D
M313D, M315D, M316D, M318D, M322D
2774337
MANIFOLD GP-INLET
AP1000E, AP1055E, C6.6, M316D, M318D, M318D MH, M322D, M322D MH, R1300G II
AP1000E, AP1055E, C6.6, M316D, M318D, M318D MH, M322D, M322D MH, R1300G II
3068859
MANIFOLD & SOLENOID GP-CONTROL
M318D MH, M322D MH
M318D MH, M322D MH
2984569
MANIFOLD-EXHAUST
914G, C4.4, CB-54, CB-54B, CB-64, CP-44, CS-44, CS-54, CS-54B, IT14G, IT14G2, M313D, M315D, M315D 2, M317D 2
914G, C4.4, CB-54, CB-54B, CB-64, CP-44, CS-44, CS-54, CS-54B, IT14G, IT14G2, M313D, M315D, M315D 2, M317D 2
2886985
MANIFOLD GP-EXHAUST
938H, AP-655D, C6.6, CP-56, CP-64, CS-74, IT38H, M316D, M318D, M318D MH, M322D, M322D MH
938H, AP-655D, C6.6, CP-56, CP-64, CS-74, IT38H, M316D, M318D, M318D MH, M322D, M322D MH
3318917
MANIFOLD-EXHAUST
2470C, 553C, 613G, AP-600D, AP-655D, BG600D, BG655D, C6.6, CP-56, CP-64, CP-76, CS-56, CS-56B, CS-64, CS-68B, CS-74, CS-74B, CS-78B, M316D, M318D, M318D MH, M322D, M322D MH, R1300G II
2470C, 553C, 613G, AP-600D, AP-655D, BG600D, BG655D, C6.6, CP-56, CP-64, CP-76, CS-56, CS-56B, CS-64, CS-68B, CS-74, CS-74B, CS-78B, M316D, M318D, M318D MH, M322D, M322D MH, R1300G II
2964791
MANIFOLD GP-EXHAUST
311D LRR, 312D, 312D L, 313D, 314D CR, 314D LCR, 315D L, 318D L, 319D, 319D L, 319D LN
311D LRR, 312D, 312D L, 313D, 314D CR, 314D LCR, 315D L, 318D L, 319D, 319D L, 319D LN
4242300
MANIFOLD GP-CONTROL
D11R, D11T
D11R, D11T
3931650
MANIFOLD GP-VALVE
CWAC-40
CWAC-40
3068859
MANIFOLD & SOLENOID GP-CONTROL
M318D MH, M322D MH
M318D MH, M322D MH