7G6064 MANIFOLD Caterpillar parts
D6H, D6H XL, D6H XR, D7H, D8N
Rating:
Alternative (cross code) number:
CA7G6064
7G-6064
7G6064
CA7G6064
7G-6064
7G6064
Weight: 51 pounds 23 kg.
TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$400.29
16 Dec 2021
US: Florida-Parts-Z
1087742 - Manifold 7G6064 for Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
This part in 5 request:
Show.
This information for suppliers only!
2023-07-26
2023-07-26
2022-02-18
2022-01-03
2017-01-04
Information:
Transmission PTO Control Selection
The transmission PTO feature controls the PTO enable output driver at J2-2 and at J2-6. The PTO enable driver is used to control an OEM supplied control system that is connected to the transmission's auxiliary output shaft. This output is capable of driving 2 Amps and will be turned ON when all of the programmed conditions have been met.This function requires a SWC input, an Output Driver, and a set of programmable parameters that are controlled by the service tool. The PTO Control function reads an operator PTO switch input in order to direct it to turn on the PTO driver. Each system has specific operational conditions that must be met. The operational conditions are set by accessing the programmable parameters with the service tool. The following items are available for tailoring the PTO operation for a specific vehicle:PTO Maximum Gear The PTO will not operate above the programmed maximum gear. The PTO will not turn on above the programmed maximum gear and will turn off if the actual gear goes above the programmed maximum gear.PTO Minimum Gear The PTO will not operate below the programmed minimum gear. The PTO will not turn on below the programmed minimum gear and will turn off if the actual gear goes below the programmed minimum gear.PTO Maximum Engine SpeedThe PTO will not operate above the programmed minimum engine speed. The PTO will turn on when the engine speed reaches the programmed maximum engine speed -50 rpm and will turn off if the engine speed goes above the programmed minimum engine speed.PTO Minimum Engine Speed The PTO will not operate below the programmed minimum engine speed. The PTO will turn on when the engine speed reaches the programmed minimum engine speed +50 rpm and will turn off if the engine speed goes below the programmed minimum engine speed.PTO Maximum Transmission Output Speed - The PTO will not operate above the programmed maximum transmission output speed. The PTO will turn on when the transmission output speed reached the programmed maximum transmission output speed -50 rpm and will turn off if the transmission output speed goes above the programmed maximum transmission output speed.PTO Minimum Transmission Output Speed The PTO will not operate below the programmed minimum transmission output speed. The PTO will turn on when the transmission output speed reached the programmed minimum transmission output speed +50 rpm and will turn off if the transmission output speed goes below the programmed minimum transmission output speed.PTO Reverse Enable The transmission will allow the PTO to operate when the transmission is in reverse if the parameter is set to enabled. The transmission will not allow the PTO to operate when the transmission is in reverse if the parameter is
The transmission PTO feature controls the PTO enable output driver at J2-2 and at J2-6. The PTO enable driver is used to control an OEM supplied control system that is connected to the transmission's auxiliary output shaft. This output is capable of driving 2 Amps and will be turned ON when all of the programmed conditions have been met.This function requires a SWC input, an Output Driver, and a set of programmable parameters that are controlled by the service tool. The PTO Control function reads an operator PTO switch input in order to direct it to turn on the PTO driver. Each system has specific operational conditions that must be met. The operational conditions are set by accessing the programmable parameters with the service tool. The following items are available for tailoring the PTO operation for a specific vehicle:PTO Maximum Gear The PTO will not operate above the programmed maximum gear. The PTO will not turn on above the programmed maximum gear and will turn off if the actual gear goes above the programmed maximum gear.PTO Minimum Gear The PTO will not operate below the programmed minimum gear. The PTO will not turn on below the programmed minimum gear and will turn off if the actual gear goes below the programmed minimum gear.PTO Maximum Engine SpeedThe PTO will not operate above the programmed minimum engine speed. The PTO will turn on when the engine speed reaches the programmed maximum engine speed -50 rpm and will turn off if the engine speed goes above the programmed minimum engine speed.PTO Minimum Engine Speed The PTO will not operate below the programmed minimum engine speed. The PTO will turn on when the engine speed reaches the programmed minimum engine speed +50 rpm and will turn off if the engine speed goes below the programmed minimum engine speed.PTO Maximum Transmission Output Speed - The PTO will not operate above the programmed maximum transmission output speed. The PTO will turn on when the transmission output speed reached the programmed maximum transmission output speed -50 rpm and will turn off if the transmission output speed goes above the programmed maximum transmission output speed.PTO Minimum Transmission Output Speed The PTO will not operate below the programmed minimum transmission output speed. The PTO will turn on when the transmission output speed reached the programmed minimum transmission output speed +50 rpm and will turn off if the transmission output speed goes below the programmed minimum transmission output speed.PTO Reverse Enable The transmission will allow the PTO to operate when the transmission is in reverse if the parameter is set to enabled. The transmission will not allow the PTO to operate when the transmission is in reverse if the parameter is
Caterpillar parts catalog:
Parts manifold Caterpillar catalog:
7N3486
MANIFOLD-EXHAUST
12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 3306, 3306B, 528B, 530B, 966C, D5B, D6C, D6D, D6E, D6E SR, D6G SR, D6H, D6H XL, D6H XR, D6R
12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 3306, 3306B, 528B, 530B, 966C, D5B, D6C, D6D, D6E, D6E SR, D6G SR, D6H, D6H XL, D6H XR, D6R
1344200
MANIFOLD-EXHAUST
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 3306, 3306B, D6D, D6E, D6F SR, D6G SR, D6G2 LGP, D6G2 XL, D6H, D6H XR, D6R
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 3306, 3306B, D6D, D6E, D6F SR, D6G SR, D6G2 LGP, D6G2 XL, D6H, D6H XR, D6R
1017352
MANIFOLD-EXHAUST
16G, 16H NA, 3196, 3406, 3406B, 3406C, 3406E, 3456, 578, 583R, 587R, 621B, 621E, 621F, 623B, 623E, 623F, 627B, 627E, 627F, 735, 740, 814B, 824C, 824G, 824G II, 825G, 825G II, 826C, 826G, 826G II, 980C...
16G, 16H NA, 3196, 3406, 3406B, 3406C, 3406E, 3456, 578, 583R, 587R, 621B, 621E, 621F, 623B, 623E, 623F, 627B, 627E, 627F, 735, 740, 814B, 824C, 824G, 824G II, 825G, 825G II, 826C, 826G, 826G II, 980C...
1045283
MANIFOLD-EXHAUST
16H NA, 3406B, 3406C, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627B, 627E, 627F, 814B, D8N, D8R, D8R II
16H NA, 3406B, 3406C, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627B, 627E, 627F, 814B, D8N, D8R, D8R II
8N5384
MANIFOLD-EXHAUST
235B, 545, 572R, 627E, 627F, 637E, 973, 973C, D7G, D7G2, D7H, D7R
235B, 545, 572R, 627E, 627F, 637E, 973, 973C, D7G, D7G2, D7H, D7R
7C8281
MANIFOLD-EXHAUST
235B, 572R, 973, D7G, D7G2, D7H, D7R
235B, 572R, 973, D7G, D7G2, D7H, D7R
8N5386
MANIFOLD-EXHAUST
235B, 545, 572R, 637E, 973, 973C, D7G, D7G2, D7H, D7R
235B, 545, 572R, 637E, 973, 973C, D7G, D7G2, D7H, D7R
1087742
MANIFOLD
578, 583R, D6H XR, D6R, D7H, D7R, D8N
578, 583R, D6H XR, D6R, D7H, D7R, D8N
8N5385
MANIFOLD-EXHAUST
545, 637E, 973, 973C, D7H
545, 637E, 973, 973C, D7H
7W4473
MANIFOLD-EXHAUST
621E, 627B, 627E, 627F, 627G, 637E, 637G, D7H
621E, 627B, 627E, 627F, 627G, 637E, 637G, D7H
3Y9984
MANIFOLD
973, D7H
973, D7H
3Y9985
MANIFOLD
973, D7H
973, D7H
9G5382
MANIFOLD AS
D6H, D6H II, D6H XL, D6H XR
D6H, D6H II, D6H XL, D6H XR
9T3320
MANIFOLD-INLET
D6H, D6H XL, D6H XR
D6H, D6H XL, D6H XR
9G5655
MANIFOLD AS
D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II
D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II
5G8136
MANIFOLD AS
517, 527, 561M, 561N, D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II, D5M, D5N, D6M, D6N
517, 527, 561M, 561N, D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II, D5M, D5N, D6M, D6N
6T8710
MANIFOLD-BOTTOM
517, 527, 561M, 578, 583R, 587R, 814B, 815B, 931B, 933, 935B, 939, D3C III, D4B, D4C III, D4H, D4H XL, D4HTSK II, D4HTSK III, D5C, D5C III, D5H, D5H XL, D5HTSK II, D5M, D6H, D6H II, D6H XL, D6H XR, D6...
517, 527, 561M, 578, 583R, 587R, 814B, 815B, 931B, 933, 935B, 939, D3C III, D4B, D4C III, D4H, D4H XL, D4HTSK II, D4HTSK III, D5C, D5C III, D5H, D5H XL, D5HTSK II, D5M, D6H, D6H II, D6H XL, D6H XR, D6...
7G5086
MANIFOLD
578, D7G, D7H, D7R, D8N, D8R
578, D7G, D7H, D7R, D8N, D8R
3T7287
MANIFOLD AS
D6H, D7H
D6H, D7H
6T0312
MANIFOLD AS
D6H, D7H
D6H, D7H
6T2845
MANIFOLD
D4H, D6H, D6H XL, D6H XR
D4H, D6H, D6H XL, D6H XR
4T7407
MANIFOLD-INLET
D6H, D6H XL, D6H XR, D7H, D7R, D8N
D6H, D6H XL, D6H XR, D7H, D7R, D8N
3W4225
MANIFOLD
D6H
D6H
5G9153
MANIFOLD
D6H, D6H XL, D6H XR
D6H, D6H XL, D6H XR