9T2219 MANIFOLD-LH Caterpillar parts
120G, 12G, 130G, 140G, 14G, 160G, 16G
Rating:
Alternative (cross code) number:
CA9T2219
9T-2219
9T2219
CA9T2219
9T-2219
9T2219
Weight: 5 pounds 2 kg.
MOTOR GRADER,
Information:
Linkage Sensor Calibrations (Lift & Tilt)
Table 2
Error Codes That Can Be Activated When Linkage Position Sensor Calibrations Are Performed
Error Code Probable Cause of Activation Recommended Actions
10F0 - Calibration Out of Range Low During calibration, the Implement ECM sensed that the duty cycle of a linkage sensor was lower than the allowable duty cycle limit. An 10F0 error can occur at either of the following two calibration points:
- Maximum Sensor Rotation In One Direction
- Maximum Sensor Rotation In The Other Direction Check that the linkage is in the correct position before trying to advance to the next step.
Check that the rotary sensor in mounted in the correct orientation.
Check that the mechanical linkage between the sensor and implement linkage is installed correctly.
Check that there is nothing blocking the lift linkage from reaching full height/full lower or the bucket from reaching full rack/full dump. "Note: Excessively large buckets can cause issues with linkage sensor calibration."
If the cause is not found, replace the indicated sensor and perform the calibration again.
10F1 - Calibration Out of Range High During calibration, the Implement ECM sensed that the duty cycle of a linkage sensor was higher than the allowable duty cycle limit. An 10F1 error can occur at either of the following two calibration points:
- Maximum Sensor Rotation In One Direction
- Maximum Sensor Rotation In The Other Direction Implement Pump Calibration (Center and Right)
Table 3
Error Codes That Can Be Activated When Pump Solenoid Calibrations Are Performed
Error Code Probable Cause of Activation Recommended Actions
104C - Hold Pressure Too High The Implement ECM recorded an average pressure that was too high for this calibration when the pump was commanded to minimum displacement and the tilt valve bypass area was closed off. Verify that the correct flash file is downloaded into the Implement ECM.
Verify that the pressure sensor used in the calibration is reading correctly by comparing the pressure shown in ET during the calibration to the pressure on a manual gauge.
104D - Hold Pressure Too Low The implement ECM was not able to build the minimum pressure required for this calibration when the pump was commanded to minimum displacement and the tilt valve bypass area was closed off. Often caused when the hydraulic plumbing / lines are incorrectly routed. Check for swapped hydraulic connections. Also check for hydraulic oil leakage.
Check that the electrical wiring from the component back to the ECM is correct and that wires/harnesses have not been swapped.
Verify that the correct flash file is downloaded into the Implement ECM
Verify that the pressure sensor used in the calibration is reading correctly by comparing the pressure shown in ET during the calibration to the pressure on a manual gauge
Check for excessive leakage through the pump, valve, and cylinder.
If root cause is not found, replace the rack solenoid indicated in the calibration and run the calibration again. Alternatively, replacing both the rack and dump solenoid may be required to resolve the issue.
104E - Hold Pressure Inconsistent During calibration, the Implement ECM could not
Table 2
Error Codes That Can Be Activated When Linkage Position Sensor Calibrations Are Performed
Error Code Probable Cause of Activation Recommended Actions
10F0 - Calibration Out of Range Low During calibration, the Implement ECM sensed that the duty cycle of a linkage sensor was lower than the allowable duty cycle limit. An 10F0 error can occur at either of the following two calibration points:
- Maximum Sensor Rotation In One Direction
- Maximum Sensor Rotation In The Other Direction Check that the linkage is in the correct position before trying to advance to the next step.
Check that the rotary sensor in mounted in the correct orientation.
Check that the mechanical linkage between the sensor and implement linkage is installed correctly.
Check that there is nothing blocking the lift linkage from reaching full height/full lower or the bucket from reaching full rack/full dump. "Note: Excessively large buckets can cause issues with linkage sensor calibration."
If the cause is not found, replace the indicated sensor and perform the calibration again.
10F1 - Calibration Out of Range High During calibration, the Implement ECM sensed that the duty cycle of a linkage sensor was higher than the allowable duty cycle limit. An 10F1 error can occur at either of the following two calibration points:
- Maximum Sensor Rotation In One Direction
- Maximum Sensor Rotation In The Other Direction Implement Pump Calibration (Center and Right)
Table 3
Error Codes That Can Be Activated When Pump Solenoid Calibrations Are Performed
Error Code Probable Cause of Activation Recommended Actions
104C - Hold Pressure Too High The Implement ECM recorded an average pressure that was too high for this calibration when the pump was commanded to minimum displacement and the tilt valve bypass area was closed off. Verify that the correct flash file is downloaded into the Implement ECM.
Verify that the pressure sensor used in the calibration is reading correctly by comparing the pressure shown in ET during the calibration to the pressure on a manual gauge.
104D - Hold Pressure Too Low The implement ECM was not able to build the minimum pressure required for this calibration when the pump was commanded to minimum displacement and the tilt valve bypass area was closed off. Often caused when the hydraulic plumbing / lines are incorrectly routed. Check for swapped hydraulic connections. Also check for hydraulic oil leakage.
Check that the electrical wiring from the component back to the ECM is correct and that wires/harnesses have not been swapped.
Verify that the correct flash file is downloaded into the Implement ECM
Verify that the pressure sensor used in the calibration is reading correctly by comparing the pressure shown in ET during the calibration to the pressure on a manual gauge
Check for excessive leakage through the pump, valve, and cylinder.
If root cause is not found, replace the rack solenoid indicated in the calibration and run the calibration again. Alternatively, replacing both the rack and dump solenoid may be required to resolve the issue.
104E - Hold Pressure Inconsistent During calibration, the Implement ECM could not
Cat SIS web machinery list:
Parts manifold Caterpillar catalog:
9S2355
MANIFOLD-EXHAUST
12F, 12G, 12H, 12H NA, 140G, 140H, 143H, 160H, 3306, 561C, D5, D5B, D5E, D6C
12F, 12G, 12H, 12H NA, 140G, 140H, 143H, 160H, 3306, 561C, D5, D5B, D5E, D6C
8S7718
MANIFOLD-EXHAUST
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 235B, 3306, 3306B, 615C, 627, 814B, 814F, 815B, 815F, 816F, 966F, 966F II, 966G, 970F, 972G,...
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 235B, 3306, 3306B, 615C, 627, 814B, 814F, 815B, 815F, 816F, 966F, 966F II, 966G, 970F, 972G,...
8S7717
MANIFOLD-EXHAUST
143H, 14G, 235B, 3306, 3306B, 615C, 627, 814B, 814F, 815B, 815F, 816F, 966F, 966F II, 966G, 970F, 972G, 980B, D6D
143H, 14G, 235B, 3306, 3306B, 615C, 627, 814B, 814F, 815B, 815F, 816F, 966F, 966F II, 966G, 970F, 972G, 980B, D6D
8S7716
MANIFOLD-EXHAUST
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 235B, 3306, 3306B, 615C, 627, 814B, 814F, 815B, 815F, 816F, 966F, 966F II, 966G, 970F, 972G,...
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 235B, 3306, 3306B, 615C, 627, 814B, 814F, 815B, 815F, 816F, 966F, 966F II, 966G, 970F, 972G,...
7N3486
MANIFOLD-EXHAUST
12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 3306, 3306B, 528B, 530B, 966C, D5B, D6C, D6D, D6E, D6E SR, D6G SR, D6H, D6H XL, D6H XR, D6R
12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 3306, 3306B, 528B, 530B, 966C, D5B, D6C, D6D, D6E, D6E SR, D6G SR, D6H, D6H XL, D6H XR, D6R
1344200
MANIFOLD-EXHAUST
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 3306, 3306B, D6D, D6E, D6F SR, D6G SR, D6G2 LGP, D6G2 XL, D6H, D6H XR, D6R
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 3306, 3306B, D6D, D6E, D6F SR, D6G SR, D6G2 LGP, D6G2 XL, D6H, D6H XR, D6R
1017352
MANIFOLD-EXHAUST
16G, 16H NA, 3196, 3406, 3406B, 3406C, 3406E, 3456, 578, 583R, 587R, 621B, 621E, 621F, 623B, 623E, 623F, 627B, 627E, 627F, 735, 740, 814B, 824C, 824G, 824G II, 825G, 825G II, 826C, 826G, 826G II, 980C...
16G, 16H NA, 3196, 3406, 3406B, 3406C, 3406E, 3456, 578, 583R, 587R, 621B, 621E, 621F, 623B, 623E, 623F, 627B, 627E, 627F, 735, 740, 814B, 824C, 824G, 824G II, 825G, 825G II, 826C, 826G, 826G II, 980C...
1P1216
MANIFOLD-EXHAUST
120G, 130G, 3304, 3304B, 518, 518C, 527, 936F, 955K, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5HTSK II, G936
120G, 130G, 3304, 3304B, 518, 518C, 527, 936F, 955K, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5HTSK II, G936
5C8564
MANIFOLD
120G, 130G, 3304, 950, D4E, D5H, D5H XL
120G, 130G, 3304, 950, D4E, D5H, D5H XL
1836854
MANIFOLD-EXHAUST
120H, 120K, 120K 2, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 160K, 3126B, 525C, 535C, 545C, 561N, 570B, 573, 580B, 584, 815B, 938G II, 950G II, 950H, 953C, 962G II, 962H, 963C, C7, D5N, D6N, IT38G II...
120H, 120K, 120K 2, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 160K, 3126B, 525C, 535C, 545C, 561N, 570B, 573, 580B, 584, 815B, 938G II, 950G II, 950H, 953C, 962G II, 962H, 963C, C7, D5N, D6N, IT38G II...
1836856
MANIFOLD-EXHAUST
120H, 120K, 120K 2, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 160K, 3126B, 525C, 535C, 545C, 561N, 570B, 573, 580B, 584, 815B, 938G II, 950G II, 950H, 953C, 962G II, 962H, 963C, C7, D5N, D6N, IT38G II...
120H, 120K, 120K 2, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 160K, 3126B, 525C, 535C, 545C, 561N, 570B, 573, 580B, 584, 815B, 938G II, 950G II, 950H, 953C, 962G II, 962H, 963C, C7, D5N, D6N, IT38G II...
3P0890
MANIFOLD AS-PUMP
120G, 12G, 130G, 140G, 160G
120G, 12G, 130G, 140G, 160G
3P2870
MANIFOLD AS
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA
3P0883
MANIFOLD AS-PUMP
120G, 12G, 130G, 140G, 160G
120G, 12G, 130G, 140G, 160G
3P0890
MANIFOLD AS-PUMP
120G, 12G, 130G, 140G, 160G
120G, 12G, 130G, 140G, 160G
1831841
MANIFOLD
D7H
D7H
1186923
MANIFOLD
D7R
D7R
3P1656
MANIFOLD
14G, 14H, 14H NA, 16G, 16H, 16H NA
14G, 14H, 14H NA, 16G, 16H, 16H NA
1740310
MANIFOLD
330B L, OEMS
330B L, OEMS
8J5917
MANIFOLD-INNER
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
8J7267
MANIFOLD-OUTER
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
8J7268
MANIFOLD-OUTER
120G, 130G, 140G, 14G, 16G
120G, 130G, 140G, 14G, 16G
9T2220
MANIFOLD-RH
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G