Stator Winding Continuity Test
Illustration 1 g03221657
Stator winding continuity test (1) Rotor (2) Stator leads
Table 1
Tools Needed     Qty    
Ohm Meter (Capable of measuring less than 0.1 ohms)     1    
Put the multimeter on the 200 ohm resistance (ohms) scale. Connect the multimeter leads between each pair of stator leads (2) of stator (1) for a total of three readings.
The resistance values should be as follows. See Specifications for the K1, 24V 3E-7295 Charging Alternator Gp, 8C-5535 Charging Alternator Gp, and 7T-2876 Charging Alternator Gp . Charging Alternator Gp ... .14 to .15 ohms 9X-0341 Charging Alternator Gp ... .55 to .56 ohms 9W-3043 Charging Alternator Gp ... .20 to .22 ohms 2Y-4212 Charging Alternator Gp ... .41 to .51 ohms 9Y-8310 Charging Alternator Gp ... .34 to .42 ohms
If the resistance is not correct, the stator is open or shorted and must be replaced.Stator Winding Ground Test
Illustration 2 g03221657
Stator winding continuity test (1) Rotor (2) Stator leads
Put the multimeter on the 20M resistance (Ohms) scale. Connect a multimeter lead to each stator lead (2) and touch the other meter lead to the stator frame.
The resistance value should be 100000 ohms or greater (meter reading 0.10 or greater).
If the meter reading is low, the stator is grounded and must be replaced.
Illustration 1 g03221657
Stator winding continuity test (1) Rotor (2) Stator leads
Table 1
Tools Needed     Qty    
Ohm Meter (Capable of measuring less than 0.1 ohms)     1    
Put the multimeter on the 200 ohm resistance (ohms) scale. Connect the multimeter leads between each pair of stator leads (2) of stator (1) for a total of three readings.
The resistance values should be as follows. See Specifications for the K1, 24V 3E-7295 Charging Alternator Gp, 8C-5535 Charging Alternator Gp, and 7T-2876 Charging Alternator Gp . Charging Alternator Gp ... .14 to .15 ohms 9X-0341 Charging Alternator Gp ... .55 to .56 ohms 9W-3043 Charging Alternator Gp ... .20 to .22 ohms 2Y-4212 Charging Alternator Gp ... .41 to .51 ohms 9Y-8310 Charging Alternator Gp ... .34 to .42 ohms
If the resistance is not correct, the stator is open or shorted and must be replaced.Stator Winding Ground Test
Illustration 2 g03221657
Stator winding continuity test (1) Rotor (2) Stator leads
Put the multimeter on the 20M resistance (Ohms) scale. Connect a multimeter lead to each stator lead (2) and touch the other meter lead to the stator frame.
The resistance value should be 100000 ohms or greater (meter reading 0.10 or greater).
If the meter reading is low, the stator is grounded and must be replaced.
Parts mast Caterpillar catalog:
0523268
MAST AR-STD
Caterpillar
Caterpillar
0523254
MAST AR
Caterpillar
Caterpillar
0523253
MAST AR-STD
Caterpillar
Caterpillar
0523252
MAST AR-STD
Caterpillar
Caterpillar
0523251
MAST AR-STD
Caterpillar
Caterpillar
0523250
MAST AR
Caterpillar
Caterpillar
0523270
MAST AR
Caterpillar
Caterpillar
0523271
MAST AR
Caterpillar
Caterpillar
0523272
MAST AR-STD
Caterpillar
Caterpillar
0523273
MAST AR
Caterpillar
Caterpillar
0523274
MAST AR
Caterpillar
Caterpillar
0523275
MAST AR
Caterpillar
Caterpillar