1790710 METER GP- Caterpillar parts
   
 
 
Rating:
 Alternative (cross code) number:
CA1790710
179-0710
1790710
 
CA1790710
179-0710
1790710
 
 
  Weight: 88 pounds 39 kg. 
  Information:
Table 1
Test Step     Voltage Reading     Voltage should be below this for 12 volt system     Voltage should be below this for 24 volt system    
4        
5        
4 minus 5 =         1.0 volt     2.0 volts    
6                
7        
6 minus 7 =         0.5 volt     1.0 volt    
8         0.5 volt     1.0 volt    
Measure the voltage between the alternator B+ terminal and the alternator case ground.
Measure the voltage across the battery. Put the red lead on the positive battery terminal, and put the black lead on the negative battery terminal. Step 5 should be completed as quickly as possible after Step 4.Expected Result: On 12 volt systems, the voltage is less than or equal to the voltage recorded in Step 4, but the voltage is within one volt. On 24 volt systems, the voltage is within 2 volts.Results:
YES - If the voltage in Step 4 is not more than 1 volt for 12 volt systems (2 volts for 24 volt systems) higher than the voltage in Step 5, this test is complete and the related wiring is correct at this time. Replace the alternator or go to Testing and Adjusting, "Component - Test" in order to test the internal parts of the alternator.
NO - If the voltage in Step 4 is more than 1 volt for 12 volt systems (2 volts for 24 volt systems) higher than the voltage in Step 5, there is high circuit resistance: corrosion, loose connections and damaged wiring. Continue to Step 6.
Check the voltage between the machine frame and the alternator B+ terminal. Record the voltage.
Check the voltage between the machine frame and the positive battery post. Step 7 should be completed as quickly as possible after Step 6. Expected Result: The voltage difference between Step 6 and Step 7 does not exceed 1 volt on 24 volt systems or 0.5 volts on 12 volt systems. Results:
YES - The voltage difference does not exceed the tolerance. The charging circuit is good. Go to Step 8 .
NO - The voltage difference exceeds the tolerance. There is high resistance in the charging circuit: loose cables, corroded cables, damaged cables, faulty circuit breaker and faulty main relay. Correct the problem and retest the system.
Check the voltage between the negative battery post and the alternator case ground. Expected Result: The voltage does not exceed 1 volt on 24 volt systems or 0.5 volts on 12 volt systems. Results:
YES - The voltage difference does not exceed the tolerance. The ground circuit is good. There is an internal problem with the alternator. Replace the alternator or go to Testing and Adjusting, "Component - Test" in order to test the internal parts of the alternator.
NO - The voltage difference exceeds the tolerance. There is high resistance in the ground circuit: loose cables, corroded cables, loose alternator
Parts meter Caterpillar catalog:
 1790700
METER AS.-BURN
 
Caterpillar
 
Caterpillar
 1726328
METER-WATT
 
Caterpillar
 
Caterpillar
 1716111
METER AS
 
Caterpillar
 
Caterpillar
 1706437
METER
 
Caterpillar
 
Caterpillar
 1697486
METER-PROCESS
 
Caterpillar
 
Caterpillar
 1691897
METER-
 
Caterpillar
  
Caterpillar
 1C3755
METER,0-10VAC,
 
Caterpillar
 
Caterpillar
 1976210
METER-SERVICE
 
Caterpillar
 
Caterpillar
 1951327
METER-WATT
 
Caterpillar
 
Caterpillar
 1872125
METER-VOLT
 
Caterpillar
 
Caterpillar
 1856231
METER-TEMP
 
Caterpillar
 
Caterpillar
 1790711
METER GP.-BURN
 
Caterpillar
 
Caterpillar