3660367 METER GP-SERVICE Caterpillar parts
308E2 CR, 311F LRR, 323D2 L, 568 FM LL, D10N
Rating:
Alternative (cross code) number:
CA3660367
366-0367
3660367
CA3660367
366-0367
3660367
EXCAVATOR, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
366-0367 3660367 Hour Timer Meter for 320D E320D Excavator Timer Meter Spare Parts
rsityhalf ????Part Name:Hour Timer Meter || ????Part Number:366-0367 3660367 || ????Application:320D E320D Excavator Timer Meter Spare Parts || ????Tip: If you need any other parts, please contact us - we are a professional sales team and have many products to offer to you. Many buyers are very satisfied with our service. You can get first-class products and high-quality services from us, believe me, you will have a pleasant shopping experience here. || ????Attention: If you are unsure if the product is suitable for your machine model. In order not to delay your use of the parts, please provide your engine nameplate or serial number and part number, and we will help you confirm if it is suitable. To avoid unnecessary returns, please carefully check the product image and part number to ensure that it is the product you want. Thank you for your support and understanding!
rsityhalf ????Part Name:Hour Timer Meter || ????Part Number:366-0367 3660367 || ????Application:320D E320D Excavator Timer Meter Spare Parts || ????Tip: If you need any other parts, please contact us - we are a professional sales team and have many products to offer to you. Many buyers are very satisfied with our service. You can get first-class products and high-quality services from us, believe me, you will have a pleasant shopping experience here. || ????Attention: If you are unsure if the product is suitable for your machine model. In order not to delay your use of the parts, please provide your engine nameplate or serial number and part number, and we will help you confirm if it is suitable. To avoid unnecessary returns, please carefully check the product image and part number to ensure that it is the product you want. Thank you for your support and understanding!
366-0367 197-8832 Remote Timer Hour Meter Fits for Caterpillar 320D E320D 303E 304E 305.5E 306E 312D2 330D2 311F Excavator
WEZHYJPAS Product Name:Remote Timer Hour Meter || Part Number: 366-0367 197-8832 || Model Number:Fits for Caterpillar Excavator 320D E320D 312D2 320D2 313D2 329D2 323D3 326D2 329D2 330D2 311F 318D2 303E 305.5E 306E2 303ECR
WEZHYJPAS Product Name:Remote Timer Hour Meter || Part Number: 366-0367 197-8832 || Model Number:Fits for Caterpillar Excavator 320D E320D 312D2 320D2 313D2 329D2 323D3 326D2 329D2 330D2 311F 318D2 303E 305.5E 306E2 303ECR
366-0367 197-8832 Remote Timer Hour Meter Fits for Caterpillar 320D E320D 303E 304E 305.5E 306E 312D2 330D2 311F Excavator
ABCGTDLPAS Product Name:Remote Timer Hour Meter || Part Number: 366-0367 197-8832 || Model Number:Fits for Caterpillar Excavator 320D E320D 312D2 320D2 313D2 329D2 323D3 326D2 329D2 330D2 311F 318D2 303E 305.5E 306E2 303ECR
ABCGTDLPAS Product Name:Remote Timer Hour Meter || Part Number: 366-0367 197-8832 || Model Number:Fits for Caterpillar Excavator 320D E320D 312D2 320D2 313D2 329D2 323D3 326D2 329D2 330D2 311F 318D2 303E 305.5E 306E2 303ECR
Compatible equipment models: 3660367:
Information:
The following materials are needed to program the voltage regulator with Cat ET :
CDVR
Cat ET Software
24 VDC control power to the voltage regulator
IBM compatible PC with serial port, 486DX2, or faster (100 MHz or higher microprocessor is recommended)
Communication Adapter IIFollow the steps below in order to program the voltage regulator with Cat ET:
Apply 24 VDC control power to the voltage regulator.
Connect the "Communication Adapter II" module between the computer and the primary "CANbus" port and start the Cat ET software. Select the appropriate communication port, if prompted.
Illustration 1 g01112515
Dialog that shows the number of electronic control modules that have been detected
Wait for the software to recognize the electronic control modules. Refer to Illustration 1.
Illustration 2 g01112560
Connect button
If the software does not automatically connect, click the "CONNECT" button at the top of the screen as shown in illustration 2.
Illustration 3 g01113063
Configuration tool
The "Service" menu contains a drop-down menu containing the "Configuration Tool" button as shown in illustration 3. Click on the "Configuration Tool" button. Select the CDVR from the list by clicking CDVR once.
Illustration 4 g01113076
Available electronic control modules
Verify that the CDVR is listed in the left panel under "AVAILABLE ECM(S)" as shown in illustration 4.
Illustration 5 g01113082
Configuration group
Select the configuration group that is to be viewed by clicking the group in the left panel. Refer to illustration 5. If necessary, expand the CDVR folder in the left panel by clicking the "+" symbol next to the CDVR label. The various parameters to be programmed or viewed in that particular configuration group become visible in the right panel.
Illustration 6 g01113121
Parameter selection
In order to program a parameter, double click that parameter in the right panel or highlight the parameter by single clicking the parameter, then press "ENTER". Refer to illustration 6.
Illustration 7 g01113102
Change parameter value
Type the new value or select a new value from the drop-down menu if the "CHANGE PARAMETER VALUE" window is available. Click on "OK". Click on "YES" in order to confirm. Refer to illustration 7.
Repeat Steps 7 through 9 for each parameter to be programmed.
Illustration 8 g01113109
Disconnect button
In order to disconnect communication, click the "DISCONNECT" button. Refer to Illustration 8. Viewing Metering Parameters Using Cat ET Software
The following items are needed to view metering parameters in the CDVR with Cat ET:
CDVR
Cat ET software
Power to the CDVR
Computer with serial port
Communication Adapter II ( 171-4400 Communication Adapter Group)Follow the steps below in order to view metering parameters in the CDVR with Cat ET.
Follow Steps 1 through 6 in this "Parameter Viewing and Configuration - Caterpillar Electronic Technician" section.
Click on the "Status Tool" button in order to view the metering parameters. Refer to Illustration 9.
Illustration 9 g01425537
Various status groups will be available. Refer to Illustration 10. Click on a status group in order to display the parameters in that group.
Illustration 10 g01425538
In order to set up custom groups, double click on "Temporary Group". Double click on the parameters that are desired in order to add the parameters to the group.
Click "OK" again to enable the group.
CDVR
Cat ET Software
24 VDC control power to the voltage regulator
IBM compatible PC with serial port, 486DX2, or faster (100 MHz or higher microprocessor is recommended)
Communication Adapter IIFollow the steps below in order to program the voltage regulator with Cat ET:
Apply 24 VDC control power to the voltage regulator.
Connect the "Communication Adapter II" module between the computer and the primary "CANbus" port and start the Cat ET software. Select the appropriate communication port, if prompted.
Illustration 1 g01112515
Dialog that shows the number of electronic control modules that have been detected
Wait for the software to recognize the electronic control modules. Refer to Illustration 1.
Illustration 2 g01112560
Connect button
If the software does not automatically connect, click the "CONNECT" button at the top of the screen as shown in illustration 2.
Illustration 3 g01113063
Configuration tool
The "Service" menu contains a drop-down menu containing the "Configuration Tool" button as shown in illustration 3. Click on the "Configuration Tool" button. Select the CDVR from the list by clicking CDVR once.
Illustration 4 g01113076
Available electronic control modules
Verify that the CDVR is listed in the left panel under "AVAILABLE ECM(S)" as shown in illustration 4.
Illustration 5 g01113082
Configuration group
Select the configuration group that is to be viewed by clicking the group in the left panel. Refer to illustration 5. If necessary, expand the CDVR folder in the left panel by clicking the "+" symbol next to the CDVR label. The various parameters to be programmed or viewed in that particular configuration group become visible in the right panel.
Illustration 6 g01113121
Parameter selection
In order to program a parameter, double click that parameter in the right panel or highlight the parameter by single clicking the parameter, then press "ENTER". Refer to illustration 6.
Illustration 7 g01113102
Change parameter value
Type the new value or select a new value from the drop-down menu if the "CHANGE PARAMETER VALUE" window is available. Click on "OK". Click on "YES" in order to confirm. Refer to illustration 7.
Repeat Steps 7 through 9 for each parameter to be programmed.
Illustration 8 g01113109
Disconnect button
In order to disconnect communication, click the "DISCONNECT" button. Refer to Illustration 8. Viewing Metering Parameters Using Cat ET Software
The following items are needed to view metering parameters in the CDVR with Cat ET:
CDVR
Cat ET software
Power to the CDVR
Computer with serial port
Communication Adapter II ( 171-4400 Communication Adapter Group)Follow the steps below in order to view metering parameters in the CDVR with Cat ET.
Follow Steps 1 through 6 in this "Parameter Viewing and Configuration - Caterpillar Electronic Technician" section.
Click on the "Status Tool" button in order to view the metering parameters. Refer to Illustration 9.
Illustration 9 g01425537
Various status groups will be available. Refer to Illustration 10. Click on a status group in order to display the parameters in that group.
Illustration 10 g01425538
In order to set up custom groups, double click on "Temporary Group". Double click on the parameters that are desired in order to add the parameters to the group.
Click "OK" again to enable the group.
Cat SIS web machinery list:
Parts meter Caterpillar catalog:
3739759
METER GP-SERVICE
300.9D
300.9D
1205966
METER GP-SERVICE
M312, M315, M318, M320
M312, M315, M318, M320
1P3444
METER ASSEM.
772, D8K
772, D8K
1495914
METER-OIL FLOW
G3612
G3612
2096587
METER-FLOW
SCT673
SCT673
3583235
METER AS
3612
3612
9S9336
METER GROUP
631C, D5, D6C
631C, D5, D6C
4N3305
METER GROUP
D6C, D7G
D6C, D7G
6N0676
METER (volt)
215, 225, 227, 235, 245, 988B, D250B, D300B
215, 225, 227, 235, 245, 988B, D250B, D300B
2P6237
METER GROUP
941, 977K, D4D
941, 977K, D4D
8S6866
METER ASSEM.
824B, D6C
824B, D6C