9G6762 METER-SERVICE Caterpillar parts
3114, 3116, 3208, 325C, 3406B, 518, 931C II, 935C II, D3B, D3C II, D4C II, D5C, D7G, FB518
Rating:
Alternative (cross code) number:
CA9G6762
9G-6762
9G6762
CA9G6762
9G-6762
9G6762
Weight: 0.30 pounds 0 kg.
EXCAVATOR, WHEEL SKIDDER,
Compatible equipment models: 9G6762:
Information:
Note: This section refers to parameters :50 through :58.Note: If you change a parameter, you must exit the parameter before the change of the parameter will take effect.
Check the wiring.
Stop the generator set.
Check the wiring.Expected Result: The wiring is correct.Results:
OK: Go to Step 2.
NOT OK: The CT polarity or PT polarity is incorrect. Reverse the polarity. See the proper wiring diagram for details. Refer to Testing And Adjusting, "Wiring Diagrams". STOP.
Check the parameter values.
Start the generator set and load with 25% to 50% of rated load. Use 0.8 power factor inductive load, if at all possible.
Check the values in parameters :04 and :05.Note: Parameter :52 (current) provides the measured value of the current in the B phase only.
Measure the ampere load on the B phase.
Measure the signal voltage level at regulator terminals 5 and 6.
Verify that it is in correct proportion to load amperes and agrees with the settings of parameters :04 and :05.Expected Result: Any parameters show negative numbers.Results:
OK: If any parameters show negative numbers, a CT or PT polarity is incorrect or the phase rotation is wrong. Verify the polarity and the rotation. STOP.
NOT OK: Go to Step 3.
Check the value of the generator output current.
Compare the value of parameter :52 to the actual generator current.Expected Result: Parameter :52 reads less than the actual generator current, which was measured by another meter.Results:
OK: Parameter :52 reads less than the actual generator current, which was measured by another meter. Slowly decrease parameter :05 until the currents match.
NOT OK: Parameter :52 reads more than the actual generator current which is measured by another meter. Slowly increase parameter :05 until the currents match.Note: If the generator set neutral is connected to ground or a neutral bus, then measure the neutral current. If a significant amount of circulating current is present, it may cause incorrect readings. A harmonic analysis is recommended in order to help determine the nature of the problem.Note: It is normal for the accuracy to be reduced at levels below 15% of rated load. The digital voltage regulator is sensitive to the size of CT. The droop current transformer should be sized in order to provide no more than 5 VAC (RMS) at full rated load but not less than 3.5 VAC either. Proper sizing will significantly aid the accuracy at lower power levels.
Check the wiring.
Stop the generator set.
Check the wiring.Expected Result: The wiring is correct.Results:
OK: Go to Step 2.
NOT OK: The CT polarity or PT polarity is incorrect. Reverse the polarity. See the proper wiring diagram for details. Refer to Testing And Adjusting, "Wiring Diagrams". STOP.
Check the parameter values.
Start the generator set and load with 25% to 50% of rated load. Use 0.8 power factor inductive load, if at all possible.
Check the values in parameters :04 and :05.Note: Parameter :52 (current) provides the measured value of the current in the B phase only.
Measure the ampere load on the B phase.
Measure the signal voltage level at regulator terminals 5 and 6.
Verify that it is in correct proportion to load amperes and agrees with the settings of parameters :04 and :05.Expected Result: Any parameters show negative numbers.Results:
OK: If any parameters show negative numbers, a CT or PT polarity is incorrect or the phase rotation is wrong. Verify the polarity and the rotation. STOP.
NOT OK: Go to Step 3.
Check the value of the generator output current.
Compare the value of parameter :52 to the actual generator current.Expected Result: Parameter :52 reads less than the actual generator current, which was measured by another meter.Results:
OK: Parameter :52 reads less than the actual generator current, which was measured by another meter. Slowly decrease parameter :05 until the currents match.
NOT OK: Parameter :52 reads more than the actual generator current which is measured by another meter. Slowly increase parameter :05 until the currents match.Note: If the generator set neutral is connected to ground or a neutral bus, then measure the neutral current. If a significant amount of circulating current is present, it may cause incorrect readings. A harmonic analysis is recommended in order to help determine the nature of the problem.Note: It is normal for the accuracy to be reduced at levels below 15% of rated load. The digital voltage regulator is sensitive to the size of CT. The droop current transformer should be sized in order to provide no more than 5 VAC (RMS) at full rated load but not less than 3.5 VAC either. Proper sizing will significantly aid the accuracy at lower power levels.
Caterpillar SIS machinery equipment:
Caterpillar SIS
3208 Industrial Engine Naturally Aspirated 90N52893-UP »
9G-6762
METER-HOUR
3116 Industrial Engine 4PG00001-UP »
9G-6762
METER GP-SERVICE
3116 Industrial Engine 2WG00001-UP »
9G-6762
METER GP-SERVICE
3114 Industrial Engine 5EF00001-UP »
9G-6762
METER GP-SERVICE
3208 Marine Engine 01Z21747-UP »
9G-6762
METER GP-SERVICE
3116 Truck Engine 7JL00001-UP »
9G-6762
METER GP-SERVICE
3208 Industrial Engine 03Z10093-UP »
9G-6762
METER GP-SERVICE
3116 Industrial Engine 2MR00001-UP »
9G-6762
METER GP-SERVICE
3208 Marine Engine 75V09526-UP »
9G-6762
METER GP-SERVICE
3208 INDUSTRIAL ENGINE 03Z00001-10092 »
9G-6762
METER-SERVICE
3114 INDUSTRIAL ENGINE 1ZG00001-UP »
9G-6762
METER-SERVICE
D3C AND D3C LGP SERIES II TRACTORS / POWERSHIFT / 7JG00001-UP (MACHINE) POWERED BY 3204 ENGINE »
9G-6762
METER-SERVICE
D3C & D3C LGP SERIES II TRACTORS / POWER SHIFT / 4HJ00001-UP (MACHINE) POWERED BY 3204 ENGINE »
9G-6762
METER-SERVICE
D3C LGP SERIES II TRACTOR / DIRECT DRIVE / 5ZG00001-UP (MACHINE) POWERED BY 3204 ENGINE »
9G-6762
METER-SERVICE
931C SERIES II TRACK LOADER / POWER SHIFT / 9AG00001-UP (MACHINE) POWERED BY 3204 ENGINE »
9G-6762
METER-SERVICE
931C & 931C LGP SERIES II TRACK LOADER / POWER SHIFT / 2AK00001-UP (MACHINE) POWERED BY 3204 ENGINE »
9G-6762
METER-SERVICE
935C SERIES II TRACK LOADER / POWER SHIFT / 5DJ00001-UP (MACHINE) POWERED BY 3204 ENGINE »
9G-6762
METER-SERVICE
D4C & D4C LGP SERIES II TRACTORS / POWER SHIFT / 7KG00001-UP (MACHINE) POWERED BY 3204 ENGINE »
9G-6762
METER-SERVICE
D5C & D5C LGP TRACTORS / POWERSHIFT / 3MK00001-UP (MACHINE) POWERED BY 3204 ENGINE »
9G-6762
METER-SERVICE
3114 ENGINE INDUSTRIAL 4KR00001-UP »
9G-6762
METER-SERVICE
Caterpillar parts catalog:
Parts meter Caterpillar catalog:
4N3700
METER-HOUR
120G, 12G, 130G, 140G, 14E, 16G, 215, 225, 235, 245, 3208, 3304, 3412, 518, 528, 621B, 627B, 631C, 633D, 637, 637D, 657B, 769, 772, 773, 777, 815, 824B, 910, 920, 930, 941, 950, 955K, 955L, 966C, 977K...
120G, 12G, 130G, 140G, 14E, 16G, 215, 225, 235, 245, 3208, 3304, 3412, 518, 528, 621B, 627B, 631C, 633D, 637, 637D, 657B, 769, 772, 773, 777, 815, 824B, 910, 920, 930, 941, 950, 955K, 955L, 966C, 977K...
6T7337
METER GP-SERVICE
215B, 311, 311B, 3126B, 3176C, 3196, 320 L, 3208, 320B, 322 FM L, 322B LN, 325, 325B L, 325C, 330, 330 L, 3304, 3304B, 3306, 3306B, 330B L, 3406B, 3406C, 3406E, 3408, 3408E, 3412, 3412E, 3456, 345B L,...
215B, 311, 311B, 3126B, 3176C, 3196, 320 L, 3208, 320B, 322 FM L, 322B LN, 325, 325B L, 325C, 330, 330 L, 3304, 3304B, 3306, 3306B, 330B L, 3406B, 3406C, 3406E, 3408, 3408E, 3412, 3412E, 3456, 345B L,...
4W9112
METER GP-SERVICE
3406B, 3406C
3406B, 3406C
9Y5733
METER GP-VOLT
3114, 3116
3114, 3116
3T8323
METER GP-SERVICE
120G, 130G, 16G, 215, 215B, 225, 235, 245, 3208, 3304, 3306, 3306B, 3406, 3406B, 3408, 3412, 518, 561D, 572G, 621, 621B, 627B, 633D, 637D, 769C, 776, 920, 943, 953, 963, 973, D4E, D4E SR, D5B, D6D, D7...
120G, 130G, 16G, 215, 215B, 225, 235, 245, 3208, 3304, 3306, 3306B, 3406, 3406B, 3408, 3412, 518, 561D, 572G, 621, 621B, 627B, 633D, 637D, 769C, 776, 920, 943, 953, 963, 973, D4E, D4E SR, D5B, D6D, D7...
1N4493
METER GP-SERVICE
3406B, 3408, 3412, 3512, G3406, G3408, G3412
3406B, 3408, 3412, 3512, G3406, G3408, G3412
9S8722
METER GP-SERVICE
3306, 3406, 3406B, 3408, 3412, 3512
3306, 3406, 3406B, 3408, 3412, 3512
4W5556
METER GP-SERVICE
3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3412D, G3406, G3408, G3408B, G3408C, G3412, G3412C, HT400, PM3412, PR-1000, PR-450C, PR-750B, RM-250C, RM-350B, RR-250, RR-250B, SM-350, SS-250
3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3412D, G3406, G3408, G3408B, G3408C, G3412, G3412C, HT400, PM3412, PR-1000, PR-450C, PR-750B, RM-250C, RM-350B, RR-250, RR-250B, SM-350, SS-250
1117252
METER-VOLT
3116, 3208
3116, 3208
1N4483
METER GP-SERVICE
3406B, 3406C, 3512
3406B, 3406C, 3512
7N0864
METER AS-SERVICE
3208, 910, 931B, D3, D3B, FB221
3208, 910, 931B, D3, D3B, FB221
6T7568
METER-SERVICE
3114, 3116, 3208
3114, 3116, 3208
8N7199
METER GP-SERVICE
3508, 3512, 3516
3508, 3512, 3516
8N3747
METER GP-SERVICE
G3306
G3306
7W8632
METER GP-SERVICE
3408, 3412, G3408, G3412
3408, 3412, G3408, G3412
9S9337
METER GP-SERVICE
631C, 633C
631C, 633C
4N1366
METER GP-SERVICE
3406, 3406B
3406, 3406B
2W8605
METER GP-HOUR
3304, 3306, 3406B, 3406C, 3408, 3412
3304, 3306, 3406B, 3406C, 3408, 3412
8N7200
METER GP-SERVICE
3508, 3512, 3516
3508, 3512, 3516
8N6701
METER GP-SERVICE
3508, 3512, 3516, 926
3508, 3512, 3516, 926
5N9235
METER GP-HOUR
3208
3208
8N7198
METER GP-SERVICE
3508, 3512, 3516
3508, 3512, 3516
8N9228
METER GP-SERVICE
3508, 3512, 3516
3508, 3512, 3516