Information:
diagnostic code is recorded when VIMS reads the voltage of the front brake oil sensor as being below normal. The voltage of the signal wire is below normal and/or shorted to ground. The sensor sends a PWM signal to the VIMS module.The possible causes of this diagnostic code are listed here:
The sensor has failed.
The signal circuit in the machine harness is shorted to ground.
The VIMS interface module has failed. This is unlikely.
CHECK THE SENSOR.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the diagnostic code. Then disconnect the machine harness from the sensor.Expected Result: If the sensor is not the cause of the diagnostic code, the diagnostic code remains active. If the sensor has failed, the diagnostic code is NO longer active. Note: VIMS may wait up to approximately 30 seconds before updating the message area.Results:
OK - This diagnostic code remains active. The sensor is not causing the diagnostic code. The machine harness or the ECM may have failed. Proceed to 2.
NOT OK - This diagnostic code is NO longer active. The machine harness is correct and the ECM is operating properly. The sensor has failed. Replace the sensor. Refer to the Testing and Adjusting, "Pulse Width Modulated (PWM) Sensor -Test" section. STOP.
CHECK THE SIGNAL CIRCUIT FOR A SHORT TO GROUND.
The sensor remains disconnected from the machine harness.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the VIMS interface module.
At the machine harness connector for the VIMS interface module, measure the resistance between the signal contact and frame ground.Expected Result: The resistance is greater than 5000 ohms.Results:
OK - Resistance is greater than 5000 ohms. The harness circuit resistance is correct. Proceed to 3
NOT OK - Resistance is less than 5000 ohms. The machine harness has failed. There is a short between frame ground and the signal circuit in the machine harness. Repair the machine harness or replace the machine harness. STOP.
CHECK IF THE DIAGNOSTIC CODE REMAINS.
Using established procedures, clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the diagnostic code.
Operate the machine.
Observe the status of the diagnostic code.Expected Result: The diagnostic code CID0830 FMI 04 is no longer active.Results:
YES - Diagnostic code is NOT active. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and then reconnected. Resume normal machine operation. STOP.
NO - Diagnostic code has not been corrected. It is unlikely that the ECM is faulty. Exit this CID/FMI procedure and perform this CID/FMI procedure again. If the cause of the fault is not found, then replace the VIMS interface module. See Testing And Adjusting, "Module - Replace". STOP.
The sensor has failed.
The signal circuit in the machine harness is shorted to ground.
The VIMS interface module has failed. This is unlikely.
CHECK THE SENSOR.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the diagnostic code. Then disconnect the machine harness from the sensor.Expected Result: If the sensor is not the cause of the diagnostic code, the diagnostic code remains active. If the sensor has failed, the diagnostic code is NO longer active. Note: VIMS may wait up to approximately 30 seconds before updating the message area.Results:
OK - This diagnostic code remains active. The sensor is not causing the diagnostic code. The machine harness or the ECM may have failed. Proceed to 2.
NOT OK - This diagnostic code is NO longer active. The machine harness is correct and the ECM is operating properly. The sensor has failed. Replace the sensor. Refer to the Testing and Adjusting, "Pulse Width Modulated (PWM) Sensor -Test" section. STOP.
CHECK THE SIGNAL CIRCUIT FOR A SHORT TO GROUND.
The sensor remains disconnected from the machine harness.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the VIMS interface module.
At the machine harness connector for the VIMS interface module, measure the resistance between the signal contact and frame ground.Expected Result: The resistance is greater than 5000 ohms.Results:
OK - Resistance is greater than 5000 ohms. The harness circuit resistance is correct. Proceed to 3
NOT OK - Resistance is less than 5000 ohms. The machine harness has failed. There is a short between frame ground and the signal circuit in the machine harness. Repair the machine harness or replace the machine harness. STOP.
CHECK IF THE DIAGNOSTIC CODE REMAINS.
Using established procedures, clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the diagnostic code.
Operate the machine.
Observe the status of the diagnostic code.Expected Result: The diagnostic code CID0830 FMI 04 is no longer active.Results:
YES - Diagnostic code is NOT active. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and then reconnected. Resume normal machine operation. STOP.
NO - Diagnostic code has not been corrected. It is unlikely that the ECM is faulty. Exit this CID/FMI procedure and perform this CID/FMI procedure again. If the cause of the fault is not found, then replace the VIMS interface module. See Testing And Adjusting, "Module - Replace". STOP.
Caterpillar parts catalog:
Parts module Caterpillar catalog:
1449930
MODULE GP-WARNING INDICATOR
216, 228, 236, 247, 248, 267, 287, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 902, 906, 908, CB-434D, CB-534D, CB-634D
216, 228, 236, 247, 248, 267, 287, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 902, 906, 908, CB-434D, CB-534D, CB-634D
2236542
MODULE GP-WARNING INDICATOR
416D, 420D, 424B, 424B HD, 424D, 428D, 430D, 432D, 442D, 446D, 906, 908
416D, 420D, 424B, 424B HD, 424D, 428D, 430D, 432D, 442D, 446D, 906, 908
1449931
MODULE GP-WARNING INDICATOR
216, 236, 416D, 420D, 424D, 428D, 430D, 432D, 438D, 442D, 446D, 902, 906, 908
216, 236, 416D, 420D, 424D, 428D, 430D, 432D, 438D, 442D, 446D, 902, 906, 908
2236539
MODULE GP-WARNING INDICATOR
216, 228, 236, 247, 248, 267, 287, 416C, 416D, 420D, 424B, 424B HD, 424D, 426C, 428D, 430D, 432D, 436C, 438D, 442D, 904B, 904H, 906, 908, CB-434D, CB-534D, CB-564D, CB-634D, CD-54
216, 228, 236, 247, 248, 267, 287, 416C, 416D, 420D, 424B, 424B HD, 424D, 426C, 428D, 430D, 432D, 436C, 438D, 442D, 904B, 904H, 906, 908, CB-434D, CB-534D, CB-564D, CB-634D, CD-54
1890148
MODULE GP-WARNING INDICATOR
420D, 428D, 430D, 432D, 438D, 442D, 446D
420D, 428D, 430D, 432D, 438D, 442D, 446D
2354398
MODULE GP-DISPLAY
TH355B, TH460B, TH560B, TH580B, THP10 II
TH355B, TH460B, TH560B, TH580B, THP10 II
1910912
MODULE GP-DISPLAY
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
1920072
MODULE GP-DISPLAY
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
1890148
MODULE GP-WARNING INDICATOR
420D, 428D, 430D, 432D, 438D, 442D, 446D
420D, 428D, 430D, 432D, 438D, 442D, 446D
1985800
MODULE
35, 45, 55
35, 45, 55
1985799
MODULE
35, 45, 55
35, 45, 55
2180404
MODULE GP-INTERFACE
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M, 246C, 24M, 256C, 262C, 272C, 277C, 287C, 297C, 311D LRR, 312D, 312D L, 314D CR, 314D LCR, 315D L, 319D, 319D L, 319D LN, 320D, 320D L, 3...
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M, 246C, 24M, 256C, 262C, 272C, 277C, 287C, 297C, 311D LRR, 312D, 312D L, 314D CR, 314D LCR, 315D L, 319D, 319D L, 319D LN, 320D, 320D L, 3...
3104772
MODULE GP-INTERFACE
12M 3, 12M 3 AWD, 140M 3, 140M 3 AWD, 160M 3, 160M 3 AWD, 246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 311F LRR, 312E, 312E L, 314E CR, 314E LCR, 316E...
12M 3, 12M 3 AWD, 140M 3, 140M 3 AWD, 160M 3, 160M 3 AWD, 246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 311F LRR, 312E, 312E L, 314E CR, 314E LCR, 316E...
3116609
MODULE GP-WARNING INDICATOR
420E, 430E, 432E, 434E, 442E, 444E, 450E
420E, 430E, 432E, 434E, 442E, 444E, 450E
2702729
MODULE GP-WARNING INDICATOR
420E, 430E, 432E, 434E, 442E, 444E
420E, 430E, 432E, 434E, 442E, 444E
3932300
MODULE GP-DISPLAY
416E, 420E, 430E, 450E
416E, 420E, 430E, 450E
2269169
MODULE AS-POWER SUPPLY
120H, 120M, 120M 2, 12H, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 140H, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H, 14M, 160H, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H, 16H, 16M, 311D LRR, 312D, 312D L, 314...
120H, 120M, 120M 2, 12H, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 140H, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H, 14M, 160H, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H, 16H, 16M, 311D LRR, 312D, 312D L, 314...