3393067 MODULE GP-WARNING INDICATOR Caterpillar parts
422E, 428E, 432E, 434E, 442E, 444E
Rating:
Alternative (cross code) number:
CA3393067
339-3067
3393067
CA3393067
339-3067
3393067
Weight: 0.97 pounds 0 kg.
BACKHOE LOADER,
3393067
Images:
Information:
Illustration 1 g01156147
Schematic for the Tip Forward SolenoidNote: The tip forward solenoid valve is only equipped on the 824H.This diagnostic code is associated with the tip forward solenoid. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal.The possible causes of this diagnostic code are listed:
The energize circuit for the solenoid valve is shorted to a +battery circuit.
The ECM has failed. This is unlikely.System Response:The machine response is listed:
The blade will tip forward or the tip forward solenoid will be powered continuously until the diagnostic code is cleared and the joystick control is centered.
Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code is corrected. Note: Ensure that the diagnostic code is active and that the diagnostic code indicator is active.Test Step 1. CHECK THE SOLENOID ENERGIZE CIRCUIT FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector from the solenoid. Disconnect the machine harness connectors J-1 and J-2 from the ECM.
At the machine harness ECM connector J2, measure the resistance from contact J2-8 (wire E920-BR) to all J1 contacts that are connected to +battery. The J1 contacts are: J1-1, J1-6 and J1-40. No J2 contacts are connected to +battery.Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between the energize circuit at contact J2-8 (wire E920-BR) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 2. CHECK THE STATUS OF THE DIAGNOSTIC CODE
Inspect the contacts of the harness connectors that are used in the solenoid circuit. Ensure that the contacts are secure. Clean all of the contacts in the harness connectors.
Reconnect all harness connectors.
Turn the key start switch to the ON position.
Enter service mode.
Operate the machine. Determine if the CID 0140 FMI 03 is active.Expected Result:The CID 0140 FMI 03 is active.Results:
YES - The CID 0140 FMI 03 is active.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Refer to the full machine electrical system schematic. Ensure that all connections in the solenoid circuit are intact, clean and secure. If the cause of this diagnostic code is not found in the machine harness, replace the solenoid. After solenoid replacement, if the diagnostic code is still active, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NO - The CID 0140 FMI 03 is not active at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation. Stop.
Caterpillar parts catalog:
Parts module Caterpillar catalog:
2648861
MODULE GP-DISPLAY
246C, 256C, 262C, 272C, 277C, 279C, 287C, 289C, 297C, 299C
246C, 256C, 262C, 272C, 277C, 279C, 287C, 289C, 297C, 299C
2162517
MODULE GP-INTERFACE
246C, 256C, 262C, 272C, 277C, 287C, 297C, 938H, 966H
246C, 256C, 262C, 272C, 277C, 287C, 297C, 938H, 966H
2180404
MODULE GP-INTERFACE
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M, 246C, 24M, 256C, 262C, 272C, 277C, 287C, 297C, 311D LRR, 312D, 312D L, 314D CR, 314D LCR, 315D L, 319D, 319D L, 319D LN, 320D, 320D L, 3...
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M, 246C, 24M, 256C, 262C, 272C, 277C, 287C, 297C, 311D LRR, 312D, 312D L, 314D CR, 314D LCR, 315D L, 319D, 319D L, 319D LN, 320D, 320D L, 3...
3104772
MODULE GP-INTERFACE
12M 3, 12M 3 AWD, 140M 3, 140M 3 AWD, 160M 3, 160M 3 AWD, 246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 311F LRR, 312E, 312E L, 314E CR, 314E LCR, 316E...
12M 3, 12M 3 AWD, 140M 3, 140M 3 AWD, 160M 3, 160M 3 AWD, 246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 311F LRR, 312E, 312E L, 314E CR, 314E LCR, 316E...
3116609
MODULE GP-WARNING INDICATOR
420E, 430E, 432E, 434E, 442E, 444E, 450E
420E, 430E, 432E, 434E, 442E, 444E, 450E
2702729
MODULE GP-WARNING INDICATOR
420E, 430E, 432E, 434E, 442E, 444E
420E, 430E, 432E, 434E, 442E, 444E
2521731
MODULE-DIODE
3208, 3304, 3304B, 3306B, 3406C, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C175-16, C175-20, C18, C27, C280-12, C280-16, C280-6, C280-8, C32, G3304, G33...
3208, 3304, 3304B, 3306B, 3406C, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C175-16, C175-20, C18, C27, C280-12, C280-16, C280-6, C280-8, C32, G3304, G33...
3429070
MODULE AS
120M 2, 12M 2, 12M 3, 12M 3 AWD, 140M 2, 140M 3, 140M 3 AWD, 160M 2, 160M 3, 160M 3 AWD, 2384C, 2484C, 2570C, 2670C, 2864C, 312E, 312E L, 314E CR, 314E LCR, 316E L, 318E L, 320E, 320E L, 320E LN, 320E...
120M 2, 12M 2, 12M 3, 12M 3 AWD, 140M 2, 140M 3, 140M 3 AWD, 160M 2, 160M 3, 160M 3 AWD, 2384C, 2484C, 2570C, 2670C, 2864C, 312E, 312E L, 314E CR, 314E LCR, 316E L, 318E L, 320E, 320E L, 320E LN, 320E...
3963838
MODULE GP-WARNING INDICATOR
416F, 420F, 428F, 430F, 432F, 434F, 444F, 450F
416F, 420F, 428F, 430F, 432F, 434F, 444F, 450F
3861736
MODULE GP-DISPLAY
416F, 420F, 430F
416F, 420F, 430F