3770742 MODULE GP-KEYPAD Caterpillar parts
836K
Rating:
Alternative (cross code) number:
CA3770742
377-0742
3770742
CA3770742
377-0742
3770742
LANDFILL COMPACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$1,478.62
15 Jul 2023
0.0022[0.00] Pounds
CN: 99887706
Vacuum Turbocharger Actuator 05450655 Dc098194 3770742 831120-0008 803955-0003 2.0 Tdi Compatible With Pajero 1515a026
OYADM ★ Increase engine power: Increase engine power output to improve vehicle performance. || ★ Improve Fuel economy: Improve fuel economy by increasing the efficiency of the engine. || ★ Enhance driving experience: Let the driver feel stronger power and acceleration performance, so as to improve the driving experience. || ★ Reduce maintenance cost: can prolong engine life, thus reducing vehicle maintenance cost. || ★ Easy installation: Installation of turbochargers is relatively simple and can be done by DIY, thus reducing installation costs.
OYADM ★ Increase engine power: Increase engine power output to improve vehicle performance. || ★ Improve Fuel economy: Improve fuel economy by increasing the efficiency of the engine. || ★ Enhance driving experience: Let the driver feel stronger power and acceleration performance, so as to improve the driving experience. || ★ Reduce maintenance cost: can prolong engine life, thus reducing vehicle maintenance cost. || ★ Easy installation: Installation of turbochargers is relatively simple and can be done by DIY, thus reducing installation costs.
Compatible equipment models: 3770742:
Information:
fault codes are associated with the spare inputs. SP fault codes are either alarm faults or shutdown faults. The three spare inputs and a spare output are for meeting the needs of the customer.
The active state can be programmed to be high or low.
The SP fault code can be designated as an alarm fault.
The SP fault code can be designated as a shutdown fault.
Delay time can be programmed.See Systems Operation, "Spare Input/Output Programming OP6". The spare inputs consist of SP1 through SP3. Also, the corresponding SP fault codes consist of SP1 through SP3.Alarm Mode Sequence Of Operation - The following procedure happens when a fault occurs in a spare input with the fault that is programmed as an alarm fault.
The GSC waits for the end of the time delay.
The fault alarm indicator FLASHES.
When the alarm code key is pressed, the fault code is shown on the upper display.
The engine continues to run or the engine is able to start.Shutdown Mode Sequence Of Operation - When a fault occurs in a spare input the spare input is active. If the spare input is programmed as a shutdown fault, then the GSC will operate in the following manner.
The GSC waits for the end of the time delay.
The fault shutdown indicator FLASHES.
The corresponding fault code SP1, SP2 or SP3 is immediately shown on the upper display of the GSC.
The engine is shut down or the engine is disabled from starting.The fault shutdown indicator remains FLASHING. The SP fault code remains shown until the ECS is turned to "OFF/RESET". After the ECS is turned to "OFF/RESET" and the cause of the spare fault is corrected, the engine is able to run. Note: Spare faults are not logged into the GSC fault log.Note: Spare faults that are programmed to shut down the engine are ignored by the GSC when the engine speed is less than the crank terminate speed.
The active state can be programmed to be high or low.
The SP fault code can be designated as an alarm fault.
The SP fault code can be designated as a shutdown fault.
Delay time can be programmed.See Systems Operation, "Spare Input/Output Programming OP6". The spare inputs consist of SP1 through SP3. Also, the corresponding SP fault codes consist of SP1 through SP3.Alarm Mode Sequence Of Operation - The following procedure happens when a fault occurs in a spare input with the fault that is programmed as an alarm fault.
The GSC waits for the end of the time delay.
The fault alarm indicator FLASHES.
When the alarm code key is pressed, the fault code is shown on the upper display.
The engine continues to run or the engine is able to start.Shutdown Mode Sequence Of Operation - When a fault occurs in a spare input the spare input is active. If the spare input is programmed as a shutdown fault, then the GSC will operate in the following manner.
The GSC waits for the end of the time delay.
The fault shutdown indicator FLASHES.
The corresponding fault code SP1, SP2 or SP3 is immediately shown on the upper display of the GSC.
The engine is shut down or the engine is disabled from starting.The fault shutdown indicator remains FLASHING. The SP fault code remains shown until the ECS is turned to "OFF/RESET". After the ECS is turned to "OFF/RESET" and the cause of the spare fault is corrected, the engine is able to run. Note: Spare faults are not logged into the GSC fault log.Note: Spare faults that are programmed to shut down the engine are ignored by the GSC when the engine speed is less than the crank terminate speed.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts module Caterpillar catalog:
2749229
MODULE GP-MESSAGE CENTER
365B, 365B L, 385B
365B, 365B L, 385B
1509266
MODULE
3512B, 3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8
3512B, 3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8
1871051
MODULE GP-QUAD GAUGE
120H, 120H ES, 120H NA, 12H ES, 12H NA, 135H, 135H NA, 140H ES, 140H NA, 14H NA, 160H ES, 160H NA, 16H NA
120H, 120H ES, 120H NA, 12H ES, 12H NA, 135H, 135H NA, 140H ES, 140H NA, 14H NA, 160H ES, 160H NA, 16H NA
1240384
MODULE GP-QUAD GAUGE
120H, 120H ES, 120H NA, 12H ES, 12H NA, 135H NA, 140H ES, 140H NA, 14H NA, 160H ES, 160H NA, 16H NA
120H, 120H ES, 120H NA, 12H ES, 12H NA, 135H NA, 140H ES, 140H NA, 14H NA, 160H ES, 160H NA, 16H NA
1538054
MODULE GP-QUAD GAUGE
3508, 3508B, 3512, 3512B, 3516, 3516B
3508, 3508B, 3512, 3512B, 3516, 3516B
3996160
MODULE AR-DIESEL EXHAUST FLUID
C13, C15, C18, C7.1, C9.3
C13, C15, C18, C7.1, C9.3
3735563
MODULE AR-DIESEL EXHAUST FLUID
966M, 966M XE, 972M, 972M XE
966M, 966M XE, 972M, 972M XE
2068856
MODULE-INTERNAL MODEM
UPS 250
UPS 250
1465526
MODULE GP-CONTROL
3606, 3608, 3612, 3616, G3606, G3608, G3612, G3616
3606, 3608, 3612, 3616, G3606, G3608, G3612, G3616
2435391
MODULE GP-SPEED & VIBRATORY
CS-423E, CS-433E
CS-423E, CS-433E