Introduction
The calibration of a component using the information display allows the ECM module to determine the correct output level. The calibration also allows the ECM to determine the correct input signal for displacement.Some of the components that are connected to the implement ECM can be calibrated by using the Cat® Electronic Technician (Cat® ET) Service Tool.Calibrations should be performed on a surface that is smooth and level.The following implement component calibrations can be performed using the information display:
Left Front Implement Pump Solenoid Calibration
Left Rear Implement Pump Solenoid Calibration
Right Front Implement Pump Solenoid Calibration
Right Rear Implement Pump Solenoid Calibration
Lift Linkage Sensor Calibration
Tilt Linkage Sensor Calibration
Implement Raise Valve #1 Calibration
Implement Lower Valve #1 Calibration
Implement Rackback Valve #1 Calibration
Implement Dump Valve #1 Calibration
Lift Lever Calibration
Tilt Lever CalibrationThe following transmission component calibrations can be performed using the information display:
Torque Converter Pedal Calibration
Impeller Clutch Solenoid CalibrationCalibration Process Using Information Display
Illustration 1 g03892813
Information display - home menu
(1) Service menu button
From the home menu on the information display, select the wrench icon to enter the service menu.
Illustration 2 g03892815
Select "Service Mode"".
Illustration 3 g03892819
Enter password.
Illustration 4 g03892821
Select "Enable".
Illustration 5 g03892826
Select "Calibrations".
Illustration 6 g03892844
Choose category of calibration and follow on-screen instructions. The information display will list initial machine conditions that must be satisfied before the ECM will allow the calibration procedure to continue. Follow the specific instructions on the display to complete the calibration procedure.Note: The “CALIBRATION REQUIRED” diagnostic will be active. The ECM will revert to the previous successful calibrated values if a calibration is aborted at any time.
The calibration of a component using the information display allows the ECM module to determine the correct output level. The calibration also allows the ECM to determine the correct input signal for displacement.Some of the components that are connected to the implement ECM can be calibrated by using the Cat® Electronic Technician (Cat® ET) Service Tool.Calibrations should be performed on a surface that is smooth and level.The following implement component calibrations can be performed using the information display:
Left Front Implement Pump Solenoid Calibration
Left Rear Implement Pump Solenoid Calibration
Right Front Implement Pump Solenoid Calibration
Right Rear Implement Pump Solenoid Calibration
Lift Linkage Sensor Calibration
Tilt Linkage Sensor Calibration
Implement Raise Valve #1 Calibration
Implement Lower Valve #1 Calibration
Implement Rackback Valve #1 Calibration
Implement Dump Valve #1 Calibration
Lift Lever Calibration
Tilt Lever CalibrationThe following transmission component calibrations can be performed using the information display:
Torque Converter Pedal Calibration
Impeller Clutch Solenoid CalibrationCalibration Process Using Information Display
Illustration 1 g03892813
Information display - home menu
(1) Service menu button
From the home menu on the information display, select the wrench icon to enter the service menu.
Illustration 2 g03892815
Select "Service Mode"".
Illustration 3 g03892819
Enter password.
Illustration 4 g03892821
Select "Enable".
Illustration 5 g03892826
Select "Calibrations".
Illustration 6 g03892844
Choose category of calibration and follow on-screen instructions. The information display will list initial machine conditions that must be satisfied before the ECM will allow the calibration procedure to continue. Follow the specific instructions on the display to complete the calibration procedure.Note: The “CALIBRATION REQUIRED” diagnostic will be active. The ECM will revert to the previous successful calibrated values if a calibration is aborted at any time.
Caterpillar parts catalog:
Parts moldboard Caterpillar catalog:
1362545
MOLDBOARD AS
16H NA
16H NA
8W8089
MOLDBOARD AS
14G, 14H, 14H NA
14G, 14H, 14H NA
8W2770
MOLDBOARD AS
120G, 130G
120G, 130G
8W1546
MOLDBOARD
120B, 120G, 12G, 130G
120B, 120G, 12G, 130G
8W8090
MOLDBOARD AS
14H, 14H NA
14H, 14H NA
1504249
MOLDBOARD AS
160H, 160H NA, 163H, 163H NA
160H, 160H NA, 163H, 163H NA
1515968
MOLDBOARD AS
12H, 140H, 140H NA, 143H, 160H, 163H, 163H NA
12H, 140H, 140H NA, 143H, 160H, 163H, 163H NA
8W7324
MOLDBOARD AS
140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
8X2443
MOLDBOARD AS
140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA